Calculator No. 01-8373 · Updated · Formula and assumptions shown below

The calculator on this page is switched off while it is checked. The formula is below, and the worked example shows how to do the sum by hand.

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

This guide explains how to determine the enthalpy of steam (specific enthalpy of wet, saturated, or superheated steam) using the steam tables and the basic enthalpy formula. You will learn what data to look up, how to apply the quality formula for wet steam, and how to handle superheated steam. The calculator below computes the specific enthalpy of wet steam when you enter pressure, temperature, and steam quality.

Formula

For wet steam (a mixture of saturated liquid and saturated vapor), the specific enthalpy is:

h = hf + x · (hg − hf)

  • h – specific enthalpy of the wet steam, in kJ/kg
  • hf – specific enthalpy of saturated liquid water at the given pressure (from steam tables), in kJ/kg
  • hg – specific enthalpy of saturated steam (dry saturated vapor) at the same pressure, in kJ/kg
  • x – steam quality (mass fraction of vapor), dimensionless (0 to 1)

For superheated steam (temperature above the saturation temperature at that pressure), you read the enthalpy directly from the superheated steam table at the given pressure and temperature – no quality calculation is needed.

Worked Example

Find the specific enthalpy of wet steam at a pressure of 200 kPa, with a quality of 0.85 (85% vapor).

From the saturated steam table at 200 kPa (approximately 120.23°C saturation temperature):

  • hf = 504.7 kJ/kg
  • hg = 2706.3 kJ/kg

Apply the formula:

h = 504.7 + 0.85 × (2706.3 − 504.7)

h = 504.7 + 0.85 × 2201.6

h = 504.7 + 1871.36

h ≈ 2376.1 kJ/kg

The calculator with the default values (p = 200 kPa, t = 120.23°C, x = 0.85) gives the same result: 2376.1 kJ/kg.

Assumptions

  • The steam tables used are based on the IAPWS-IF97 industrial formulation for water and steam properties.
  • For wet steam, the mixture is assumed to be in equilibrium at the saturation temperature corresponding to the given pressure.
  • Kinetic and potential energy effects are neglected – this is a thermodynamic property, not a flow energy.
  • The quality x is the mass fraction of vapor in the mixture; the calculator does not check whether the temperature matches the saturation temperature – you must enter the correct saturation temperature for the pressure, or the result is still valid only if the mixture is actually saturated.

When to Use This Calculation

You need the enthalpy of steam when performing energy balances for boilers, turbines, condensers, heat exchangers, or steam distribution systems. The enthalpy value lets you compute the heat added or removed in a process. For example, the heat required to produce steam in a boiler is the difference between the enthalpy of the exiting steam and the enthalpy of the entering feedwater.

For saturated steam (x = 1), the formula reduces to h = hg. For saturated water (x = 0), it reduces to h = hf. For superheated steam, you do not use quality – you look up the enthalpy directly in the superheated steam table at the actual pressure and temperature.

Common Mistakes

  • Using the wrong table: Make sure you use the saturated steam table for wet/saturated steam and the superheated steam table for superheated steam. Mixing them up gives wildly wrong values.
  • Forgetting to convert pressure units: Steam tables are often given in bar, kPa, MPa, or psi. Always convert to the same units as your table. For example, 1 bar = 100 kPa.
  • Misreading quality: Quality x is a fraction (0.85), not a percentage (85). If you enter 85 instead of 0.85, the result will be far too high.
  • Using hfg directly: The latent heat hfg = hg − hf is already included in the formula – do not add it again.
  • Ignoring the saturation temperature: For wet steam, the temperature must be the saturation temperature at that pressure. If you enter a different temperature, the steam is not saturated and the quality formula does not apply.

Tips

  • Always write down the pressure and temperature you are using, and verify that the saturation temperature from the table matches the temperature you entered for wet steam.
  • For superheated steam, interpolation between table entries is often necessary. Use linear interpolation for reasonable accuracy.
  • Use consistent units: if the table gives enthalpy in kJ/kg, keep your calculations in kJ/kg. If you need BTU/lb, convert using 1 kJ/kg ≈ 0.4299 BTU/lb.
  • When using online steam tables, check whether they use the IAPWS-IF97 standard – this is the most common and accurate.
  • For quick estimates, you can use the approximation h ≈ hg for dry saturated steam, but always use the table for precise work.

Troubleshooting

Result seems too low or too high: Check that you entered the correct pressure and temperature. Verify that the steam table values you used are for the same pressure. If you used a different pressure, the hf and hg values will be wrong.

Quality is not between 0 and 1: If you have a mixture, quality must be between 0 and 1. If you calculated quality and got a negative number or greater than 1, the steam is not wet – it is either compressed liquid (x < 0) or superheated (x > 1). Use the appropriate table.

Temperature does not match saturation: For wet steam, the temperature must equal the saturation temperature at the given pressure. If you have a temperature higher than saturation, use the superheated table. If lower, you have subcooled liquid – use the compressed liquid table or approximate as saturated liquid.

Calculator shows “Cannot compute”: This happens if the quality is outside 0–1. Check your input. Also, ensure the pressure is positive (absolute pressure, not gauge).

Interpolation errors: When reading superheated tables, if your temperature or pressure falls between two entries, interpolate linearly. For example, if enthalpy at 300°C is 3069 kJ/kg and at 350°C is 3158 kJ/kg, the value at 325°C is approximately (3069+3158)/2 = 3113.5 kJ/kg.

Frequently Asked Questions

Q: What is the difference between enthalpy of steam and internal energy?
A: Enthalpy (h) includes the internal energy plus the product of pressure and specific volume (h = u + pv). For steam, the pv term is significant, so enthalpy is larger than internal energy. Enthalpy is used for open systems like turbines and boilers because it accounts for flow work.

Q: Can I use the same formula for superheated steam?
A: No. For superheated steam, you read the enthalpy directly from the superheated steam table at the given pressure and temperature. The quality formula only applies to saturated mixtures (wet steam).

Q: What is steam quality and how do I find it?
A: Steam quality (x) is the mass fraction of vapor in a saturated mixture. It can be measured with a calorimeter or determined from a throttling process. If you know the specific volume or internal energy of the mixture, you can calculate x using the saturated values.

Q: Why do steam tables list hf, hg, and hfg?
A: hf is the enthalpy of saturated liquid, hg is the enthalpy of saturated vapor, and hfg is the latent heat of vaporization (hg − hf). They are provided so you can compute the enthalpy of any mixture using the quality formula.

Q: Does the enthalpy of steam depend on pressure?
A: Yes, significantly. At higher pressures, the saturation temperature increases and the latent heat decreases. For example, at 100 kPa, hfg ≈ 2258 kJ/kg, while at 10 MPa, hfg ≈ 1317 kJ/kg. Always use the values at your specific pressure.

Q: What are typical units for enthalpy of steam?
A: The SI unit is kilojoules per kilogram (kJ/kg). In imperial units, it is often given in BTU per pound (BTU/lb). Conversion: 1 kJ/kg ≈ 0.4299 BTU/lb.

Related

Formula used
in p | Pressure | kPa | 200 | 0.1
in t | Temperature | °C | 120.23 | -273.15
in x | Steam quality (0-1) | - | 0.85 | 0 | 1
out h | Specific enthalpy | kJ/kg | hf + x * (hg - hf) | 1

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →