molecalculator

Moles & Molar Mass

Nth Order Kinetics Formula and Rate Law Calculator

Calculator No. 01-6545 · Updated · Formula and assumptions shown below

Reaction rate 0.0500 mol/(L·s)
Rate constant units
1
= 1
Rate constant k
0.2 (mol/L)^(1-n)/s
Set in the form below
Reactant concentration [A]
0.5 mol/L
Set in the form below
You enter
Rate constant k ((mol/L)^(1-n)/s), Reactant concentration [A] (mol/L), Reaction order n
You get
Reaction rate (mol/(L·s)), Rate constant units
Rounding
4 dp · 0 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

The nth-order kinetics formula relates a reaction’s rate to the concentration of a reactant raised to the power n: rate = k[A]n. Enter the rate constant, reactant concentration, and reaction order to calculate the rate; the result follows the rate-law units implied by your chosen order.

Formula

The nth-order rate law is r = k[A]n. Here, r is the reaction rate in mol·L−1·s−1, k is the rate constant, [A] is the concentration of reactant A in mol·L−1, and n is the order with respect to A. For a single-reactant rate law, k has units (mol·L−1)1−n·s−1, so the rate has the same units at every order. The calculator treats n as a nonnegative real number; many textbook examples use integer orders.

The expression “nth order” describes how concentration affects rate, not a universal reaction mechanism. For a multireactant law, such as r = k[A]m[B]p, the overall order is m + p, and each reactant can have its own order. The calculator’s single concentration input represents the one-concentration form.

Worked Example

Using the defaults, k = 0.2 (mol/L)−1·s−1, [A] = 0.5 mol/L, and n = 2:

  1. Write the rate law: r = k[A]n.
  2. Substitute the values: r = 0.2 × (0.5)2.
  3. Square the concentration: (0.5)2 = 0.25.
  4. Multiply: r = 0.2 × 0.25 = 0.0500 mol·L−1·s−1.

The units agree: (mol/L)−1·s−1 × (mol/L)2 = mol·L−1·s−1. The first output is the rate. The second output is a placeholder, not a calculation of rate-constant units; those units depend on n and are given in the formula section.

Assumptions

  • The input rate constant matches the chosen reaction order and the time unit is seconds.
  • The concentration is nonnegative and expressed in mol/L.
  • The stated rate law applies to the conditions and concentration range of interest; no temperature correction or mechanism is inferred.

What Reaction Order Means

Reaction order is an experimentally determined exponent in a rate law. It tells how rate changes when concentration changes while other relevant conditions remain fixed. If the reaction is first order in A, doubling [A] doubles the rate. If it is second order in A, doubling [A] multiplies the rate by four. A zero-order dependence means changing [A] does not change the rate over the range where that rate law holds.

These exponents are not automatically the coefficients in a balanced chemical equation. They match stoichiometric coefficients only for an elementary reaction step, under the appropriate rate-law description. For an overall reaction made of multiple steps, the observed law must generally be found from data or derived from a validated mechanism.

How to Use the Rate Law

Use the calculator when k, concentration, and order are already known and you need the instantaneous rate predicted by that rate law. Keep concentration and k units consistent: if concentration is entered in mol/L, the k units must be based on mol/L as well. If time is reported in minutes, convert k’s time basis to seconds or interpret the calculated rate in matching time units.

  • Check the order: use the experimentally established exponent, not an assumed stoichiometric coefficient.
  • Check k’s units: for first order, k is s−1; for second order, it is L·mol−1·s−1; for zero order, it is mol·L−1·s−1.
  • Check the concentration basis: mol/L and mol/m3 differ by a factor of 1000, which can substantially alter a calculated rate, especially at higher orders.
  • Use suitable significant figures: calculator digits do not imply greater experimental precision than the measurements or fitted k value.

For n = 0, the expression reduces to r = k. For n = 1, r = k[A]. For n = 2, r = k[A]2. These are common cases, but fractional and negative apparent orders can also appear in experimentally fitted rate laws. Since this calculator restricts n to nonnegative values, it does not cover negative-order models.

Rate Law Versus Integrated Rate Law

The rate law calculates rate at a particular concentration; it does not directly give concentration after a specified time. To predict concentration as a function of time, use an integrated rate law. For a single reactant with a constant-volume, simple nth-order law, the differential equation is −d[A]/dt = k[A]n. For n ≠ 1, integration gives [A]1−n = [A]01−n + (n−1)kt, where [A]0 is the initial concentration. For n = 1, the result is ln([A]/[A]0) = −kt.

These integrated forms rely on the stated single-reactant model and a consistent definition of reaction rate. A reaction’s disappearance rate and product-formation rate can differ by stoichiometric factors, so check how the source defines “rate” before comparing values.

Common Misconceptions and Limits

A frequent misconception is that “second order” means every reactant concentration is squared. It may instead mean a product of two first-power concentrations, such as r = k[A][B], whose overall order is two. In that case, the rate depends separately on both reactants, so the one-input calculator is not enough.

The formula also does not explain why a reaction has a given rate or guarantee that the same k remains valid at all temperatures, pressures, or solution compositions. Rate constants commonly depend on conditions, and empirical rate laws are usually reliable only within the domain in which they were established. For bench work, follow your lab method, the safety data sheet (SDS), and your supervisor.

Frequently Asked Questions

What is the formula for nth-order kinetics?
The single-reactant rate law is r = k[A]n, where k is the rate constant, [A] is reactant concentration, and n is the reaction order.

What are the units of k for an nth-order reaction?
For rate in mol·L−1·s−1 and concentration in mol·L−1, k has units (mol·L−1)1−n·s−1. Thus the units change with the order.

How does doubling concentration affect the rate?
For a single-reactant law, the rate changes by a factor of 2n. It doubles for n = 1 and becomes four times as large for n = 2, assuming other conditions are unchanged.

Is reaction order the same as a balanced-equation coefficient?
Not generally. Orders are determined from the rate law, usually experimentally. Stoichiometric coefficients directly indicate exponents only for an elementary step under the applicable model.

Does this formula calculate concentration after a given time?
No. It gives the rate at the supplied concentration. Finding concentration over time requires an integrated rate law and an initial concentration and elapsed time.

Related

Formula used
in k | Rate constant k | (mol/L)^(1-n)/s | 0.2 | 0
in a | Reactant concentration [A] | mol/L | 0.5 | 0
in n | Reaction order n | - | 2 | 0
out r | Reaction rate | mol/(L·s) | k * a^n | 4
out u | Rate constant units | - | 1 | 0

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →