This calculator converts a pressure change in psi into the corresponding gas volume change, using the ideal gas law for a fixed amount of gas at constant temperature. You enter the initial volume, the initial pressure, and the new pressure, and you get the new volume in the same unit you used for the initial volume (liters, cubic feet, etc.). The calculation assumes the gas behaves ideally and the temperature stays constant.

Formula

The calculator uses Boyle’s Law, which states that for a fixed amount of gas at constant temperature, pressure and volume are inversely proportional:

P₁V₁ = P₂V₂

Solving for the new volume:

V₂ = V₁ × (P₁ / P₂)

Where:

  • V₁ = initial volume (any unit, e.g., L, mL, ft³, m³)
  • P₁ = initial absolute pressure (psi)
  • P₂ = new absolute pressure (psi)
  • V₂ = new volume (same unit as V₁)

Important: Pressures must be absolute pressures, not gauge pressures. Gauge pressure (what a typical tire gauge reads) is the pressure above atmospheric. To convert gauge to absolute, add atmospheric pressure (14.7 psi at sea level). For example, if a gauge reads 30 psi, the absolute pressure is 30 + 14.7 = 44.7 psi.

Worked Example

Using the default values from the calculator:

  • Initial volume (V₁) = 10 L
  • Initial absolute pressure (P₁) = 14.7 psi (standard atmospheric pressure)
  • New absolute pressure (P₂) = 29.4 psi

Apply the formula:

V₂ = V₁ × (P₁ / P₂) = 10 L × (14.7 / 29.4) = 10 L × 0.5 = 5 L

The calculator shows 5.000 L, which matches. The pressure doubled, so the volume halved, as expected from Boyle’s Law.

Assumptions

  • The gas behaves as an ideal gas (no intermolecular forces, molecules occupy negligible volume).
  • Temperature is constant (isothermal process).
  • The amount of gas (number of moles) does not change.
  • Pressures entered are absolute pressures, not gauge pressures.

When to Use This Calculator

This tool is useful for anyone working with compressed gases, pneumatic systems, scuba tanks, or even understanding how a balloon changes size with altitude. You might use it to:

  • Estimate the volume of air released from a compressed air tank when pressure drops.
  • Calculate how much gas remains in a cylinder at a given pressure if you know its water volume and full pressure.
  • Understand how a sealed container’s volume changes when you move it from sea level to a higher altitude (lower atmospheric pressure).
  • Check the math behind a gas piston or accumulator.

Remember, this is a planning and study tool. For real-world engineering, always consult relevant standards and safety guidelines.

How to Read the Result

The result (V₂) is the volume the gas will occupy at the new pressure, assuming the same temperature and amount of gas. If the new pressure is higher than the initial, the volume will be smaller; if lower, the volume will be larger. The ratio output (P₂/P₁) shows you the pressure multiplier—useful for quick checks.

For example, if you have a 10 L container at 14.7 psi and you compress it to 29.4 psi, the gas would occupy 5 L if it could expand freely. In a rigid container, the volume doesn’t change; instead, the pressure would increase—but that’s a different calculation (Gay-Lussac’s law).

Common Mistakes and Misconceptions

  • Using gauge pressure instead of absolute pressure. This is the most common error. Always convert gauge to absolute by adding 14.7 psi (at sea level). For example, if a tire is at 32 psi gauge, use 46.7 psi absolute in the formula.
  • Forgetting that temperature must be constant. If the gas heats up or cools down, Boyle’s Law doesn’t apply directly. You’d need the combined gas law.
  • Assuming the container volume changes. If the gas is in a rigid tank, the volume is fixed; pressure changes instead. This calculator is for a flexible or expandable volume (like a balloon or piston).
  • Mixing units. The volume unit can be anything, but it must be the same for V₁ and V₂. Pressure must be in psi for both, or convert consistently (1 atm = 14.6959 psi, 1 bar = 14.5038 psi).

Limitations of the Ideal Gas Law

The ideal gas law is accurate for most gases at moderate pressures and temperatures, but it breaks down at very high pressures (e.g., > a few hundred psi) or very low temperatures, where intermolecular forces become significant. For such conditions, use the van der Waals equation or other real-gas models. Also, this calculator ignores the volume of the gas molecules themselves, which is negligible at normal conditions but not at extreme pressures.

For most practical purposes—like estimating scuba tank air consumption or sizing an air reservoir—the ideal gas approximation is sufficient.

Frequently Asked Questions

Do I use gauge or absolute pressure?

Always use absolute pressure in Boyle’s Law. Gauge pressure is relative to atmospheric pressure. To convert, add 14.7 psi (or 101.325 kPa) to the gauge reading. If you use gauge pressure, the result will be wrong—often dramatically so.

Can I use this for scuba tanks?

Yes, but with caution. Scuba tanks are rigid, so the volume doesn’t change; instead, the pressure changes as you breathe. To estimate how much air is left, you’d use the tank’s rated volume (e.g., 12 L) and the current pressure. This calculator can help if you want to know what volume the air would occupy at the surface (1 atm). For example, a 12 L tank at 200 bar (about 2900 psi) holds 12 L × (2900/14.7) ≈ 2367 L of air at surface pressure. But always follow dive training and use a submersible pressure gauge.

What if the temperature changes?

Then Boyle’s Law isn’t enough. Use the combined gas law: P₁V₁/T₁ = P₂V₂/T₂, where temperatures are in Kelvin. This calculator assumes constant temperature, so it’s only valid for isothermal processes.

Can I use psi and liters together?

Yes, because psi and liters are independent units. The formula only requires that pressure units match (both psi) and volume units match (both liters). You could use cubic feet and psi as well—the result will be in cubic feet.

Why does the calculator ask for absolute pressure?

Because the ideal gas law is based on absolute pressure. Using gauge pressure would give incorrect results, as the zero point is offset by atmospheric pressure. The calculator’s default initial pressure of 14.7 psi is standard atmospheric pressure at sea level, which is a common reference point.

Is this calculator useful for compressed air systems?

Yes, for estimating how much air is stored in a receiver tank or how much volume is delivered at a given pressure. For example, if a 100-gallon tank is at 150 psi (gauge), the absolute pressure is 164.7 psi, and the air would occupy 100 × (164.7/14.7) ≈ 1120 gallons at atmospheric pressure. This helps size compressors and piping.

Related

Formula used
in v1 | Initial volume | L | 10 | 0 | -
in p1 | Initial pressure (absolute) | psi | 14.7 | 0 | -
in p2 | New pressure (absolute) | psi | 29.4 | 0 | -
out v2 | New volume | L | v1 * p1 / p2 | 3 |
out ratio | Pressure ratio (p2/p1) | - | p2 / p1 | 3 |