molecalculator

Moles & Molar Mass

Saturation Mixing Ratio Formula & Calculator

Calculator No. 01-11151 · Updated · Formula and assumptions shown below

The calculator on this page is switched off while it is checked. The formula is below, and the worked example shows how to do the sum by hand.

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

The saturation mixing ratio formula calculates the maximum mass of water vapor that can be held in a given mass of dry air at a specific temperature and pressure. You enter temperature and pressure, and the calculator returns the saturation mixing ratio in grams of water vapor per kilogram of dry air (g/kg). This value is central to meteorology, HVAC design, and any field where air moisture content matters.

Formula

The saturation mixing ratio \( r_s \) is given by:

\( r_s = \frac{0.622 \, e_s}{p – e_s} \)

where \( e_s \) is the saturation vapor pressure (in the same pressure units as \( p \)), \( p \) is the total atmospheric pressure, and 0.622 is the ratio of the molar mass of water (18.015 g/mol) to the molar mass of dry air (28.97 g/mol). In the calculator, \( e_s \) is computed using the Magnus formula (often called the Tetens formula) for the saturation vapor pressure over liquid water:

\( e_s = 611.2 \, \exp\left(\frac{17.67 \, T}{T + 243.5}\right) \)

where \( T \) is temperature in °C and \( e_s \) is in pascals (Pa). The calculator converts to hPa by dividing by 100. The formula assumes pure liquid water and a flat surface; it is accurate to about 0.1% for temperatures between −30°C and +35°C.

Worked Example

Using the default values: temperature = 25°C, pressure = 1013.25 hPa.

  1. Compute the saturation vapor pressure (in Pa):
    \( e_s = 611.2 \times \exp\left(\frac{17.67 \times 25}{25 + 243.5}\right) = 611.2 \times \exp(1.646) = 611.2 \times 5.184 = 3168.5 \, \text{Pa} \)
  2. Convert to hPa: \( e_s = 31.685 \, \text{hPa} \)
  3. Apply the mixing ratio formula:
    \( r_s = \frac{0.622 \times 31.685}{1013.25 – 31.685} = \frac{19.708}{981.565} = 0.02008 \, \text{kg/kg} \)
  4. Convert to g/kg: \( 0.02008 \times 1000 = 20.08 \, \text{g/kg} \)

The calculator shows 20.08 g/kg, matching the step-by-step result.

Assumptions

  • The air is an ideal gas mixture (valid for atmospheric conditions).
  • The water vapor is in equilibrium with a flat surface of pure liquid water.
  • The Magnus formula is used for saturation vapor pressure; it is an empirical approximation, not a fundamental law.
  • Pressure is total atmospheric pressure; the formula does not account for the effect of dissolved substances (e.g., in seawater) or curved surfaces (e.g., cloud droplets).

How to Read the Result

The saturation mixing ratio tells you the maximum amount of water vapor that 1 kg of dry air can hold before condensation occurs. For example, at 25°C and sea-level pressure, air can hold about 20 g of water vapor per kg of dry air. If the actual mixing ratio is lower, the air is unsaturated; if it equals the saturation value, the relative humidity is 100%. The actual mixing ratio is often measured by a hygrometer or calculated from dew point. The difference between actual and saturation mixing ratio is a key driver of evaporation and cloud formation.

When to Use Saturation Mixing Ratio

Use this calculator when you need to:

  • Convert between relative humidity, dew point, and mixing ratio (e.g., for weather forecasting).
  • Design HVAC systems: determine how much moisture air can remove or add.
  • Estimate the water content of air for industrial drying processes.
  • Understand or predict fog, dew, and cloud formation.

For meteorological work, you often need the saturation mixing ratio at a given pressure level (e.g., 850 hPa). The calculator works for any pressure within the valid range.

Common Mistakes and Misconceptions

  • Confusing mixing ratio with specific humidity: Mixing ratio is grams of water per kilogram of dry air; specific humidity is grams of water per kilogram of moist air. They differ by only a few percent at typical atmospheric levels.
  • Forgetting to convert units: The Magnus formula requires temperature in °C and pressure in Pa or hPa. If you use °F or kPa, you’ll get wildly wrong numbers.
  • Using the wrong saturation vapor pressure formula: There are many approximations (Goff-Gratch, Buck, Magnus). The Magnus formula is simple and accurate for most purposes, but at temperatures below −30°C or above 35°C, errors grow.
  • Assuming saturation over ice: At subfreezing temperatures, the saturation vapor pressure over ice is lower than over liquid water. This calculator uses liquid water, so at −10°C it overestimates the mixing ratio by about 10%.
  • Ignoring pressure dependence: The mixing ratio depends on pressure; at higher altitudes (lower pressure), the same temperature yields a higher mixing ratio because there is less dry air mass.

Limitations and Alternatives

The Magnus formula is an empirical fit; it is not exact. For high-precision work (e.g., calibration of instruments), use the more accurate Goff-Gratch equation or the WMO reference formulas. Also, the formula assumes pure water; for seawater or solutions, the saturation vapor pressure is reduced by the Raoult’s law effect. For curved droplets (like in clouds), the Kelvin effect increases the saturation vapor pressure. These effects are small in most practical applications but matter in cloud physics.

If you need the actual mixing ratio (not saturation), you can compute it from relative humidity: \( r = (RH/100) \times r_s \). Alternatively, if you know the dew point, use the saturation mixing ratio at the dew point to get the actual mixing ratio.

Frequently Asked Questions

What is the difference between saturation mixing ratio and relative humidity?

Relative humidity is the ratio (in percent) of the actual vapor pressure to the saturation vapor pressure at the same temperature. Saturation mixing ratio is an absolute measure of the maximum water vapor mass per unit mass of dry air. At a given temperature, RH tells you how close to saturation the air is, while mixing ratio tells you the actual mass of water present.

How do I convert from saturation mixing ratio to dew point?

You can invert the formula: given \( r_s \), solve for \( e_s = r_s \times p / (0.622 + r_s) \), then use the inverse Magnus formula: \( T_d = (243.5 \times \ln(e_s/611.2)) / (17.67 – \ln(e_s/611.2)) \). The result is the dew point in °C.

Why does the saturation mixing ratio increase with temperature?

Warmer air has more kinetic energy, allowing more water molecules to evaporate before the rate of condensation equals the rate of evaporation. The Clausius-Clapeyron relation shows that saturation vapor pressure increases roughly exponentially with temperature, so the mixing ratio does too.

Does pressure affect saturation mixing ratio?

Yes. For a given temperature, the saturation vapor pressure is fixed, but the mixing ratio formula includes total pressure in the denominator. Lower pressure (e.g., at high altitude) means less dry air mass, so the same amount of water vapor yields a higher mixing ratio. This is why the same temperature at 500 hPa can have a saturation mixing ratio roughly double that at 1000 hPa.

Can I use this for subfreezing temperatures?

Yes, but be aware that the calculator uses the saturation vapor pressure over liquid water. At temperatures below 0°C, the saturation vapor pressure over ice is lower, so the true saturation mixing ratio over ice is lower. For temperatures down to about −30°C, the error is up to a few percent; below that, it grows. For ice clouds, use a formula that accounts for ice.

What are typical saturation mixing ratio values?

At sea level (1013 hPa), the saturation mixing ratio is about 3.8 g/kg at 0°C, 14 g/kg at 20°C, 20 g/kg at 25°C, and 28 g/kg at 30°C. In the tropics, surface values can exceed 25 g/kg, while in polar regions they are often below 1 g/kg.

Related

Formula used
in t | Temperature | °C | 25 | -80 | 60
in p | Pressure | hPa | 1013.25 | 100 | 1100
out r | Saturation mixing ratio | g/kg | (611.2 * exp(17.67 * t / (t + 243.5)) * 0.622 * 1000) / (p - 611.2 * exp(17.67 * t / (t + 243.5))) | 2
out e | Saturation vapor pressure | hPa | 611.2 * exp(17.67 * t / (t + 243.5)) / 100 | 2

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.