This calculator finds the concentration of a reactant remaining after a specified time for a second-order reaction with one reactant, using its initial concentration and rate constant. Enter the initial concentration, rate constant, and elapsed time; it returns the concentration predicted by the integrated rate law.
Formula
For a second-order reaction involving one reactant, A → products, the differential rate equation is −d[A]/dt = k[A]2. Its integrated form is 1/[A]t = 1/[A]0 + kt, or [A]t = 1 / (1/[A]0 + kt). The calculator uses this integrated equation.
- [A]0 (a) is the initial concentration of A in mol/L.
- [A]t (c) is its concentration after time t, in mol/L.
- k is the second-order rate constant, in L/(mol·s) when time is entered in seconds.
- t is elapsed time in seconds.
- Fraction remaining is [A]t/[A]0, a dimensionless ratio.
The units of k must match the concentration and time units. If concentration is in mol/L and time is in seconds, k has units L/(mol·s). The rate itself, −d[A]/dt, has units mol/(L·s). The minus sign indicates that A is being consumed; the positive rate of disappearance is k[A]2.
Worked Example
Use the calculator defaults: [A]0 = 0.100 mol/L, k = 0.50 L/(mol·s), and t = 60 s.
- Apply the reciprocal form: 1/[A]t = 1/(0.100 mol/L) + (0.50 L/(mol·s))(60 s).
- Evaluate the terms: 1/[A]t = 10.000 L/mol + 30.000 L/mol = 40.000 L/mol.
- Take the reciprocal: [A]t = 1/(40.000 L/mol) = 0.02500 mol/L. To four decimal places, the calculator displays 0.0250 mol/L.
- Calculate the fraction remaining: 0.02500/0.100 = 0.2500, or 25.00%.
Assumptions
- The reaction follows the single-reactant rate law −d[A]/dt = k[A]2 throughout the time interval.
- The rate constant is constant under the conditions considered, and the concentration is sufficiently well mixed for a bulk concentration to be meaningful.
- The model treats the reaction as irreversible for the purpose of calculating A remaining; it does not account for reverse reaction, changing conditions, or competing pathways.
What Second-Order Kinetics Means
A reaction is described as second order when the total exponent of concentration in its rate law is two. In the one-reactant case used here, doubling [A] makes the instantaneous rate four times as large, because the rate is proportional to [A]2. This dependence applies to the rate at a particular moment, not directly to the total amount reacted over any fixed time.
“Second order” does not always mean a squared concentration. A reaction with rate law rate = k[A][B] is also second order overall: it is first order in A and first order in B. That two-reactant case requires information about both concentrations and generally has a different integrated equation. The calculator here is specifically for a single reactant whose measured rate law is k[A]2.
Reaction order is determined experimentally from how rate changes with concentration; it is not automatically read from the balanced chemical equation. For an elementary reaction step, molecular participation can inform its rate law, but an overall reaction may proceed through multiple steps and need not have coefficients that equal rate-law exponents.
How to Use the Integrated Equation
The formula is useful when a rate constant and initial concentration are known and the question is how much reactant remains after a chosen time. It can also be rearranged to analyze experimental data:
- Plot 1/[A] against time. A straight line supports the single-reactant second-order model over the measured range.
- The slope of that line is k, and its intercept is 1/[A]0.
- With two concentration measurements, calculate k = (1/[A]t − 1/[A]0)/t, provided the model applies and the measurements are consistent.
For a second-order reaction, the half-life is not constant. Setting [A]t = [A]0/2 in the integrated equation gives t1/2 = 1/(k[A]0). With the example values, t1/2 = 1/(0.50 × 0.100) = 20 s. If the initial concentration is halved while k stays the same, the half-life doubles. This differs from first-order kinetics, where half-life is independent of initial concentration.
Choosing Units and Checking Results
Use one consistent concentration unit and a time unit that agrees with k. For example, if k is reported in L/(mol·min), enter time in minutes after converting it; do not combine that constant with seconds without conversion. If concentrations are entered in mmol/L instead of mol/L, the numerical value and units of k must also be adjusted consistently.
For positive initial concentration, nonnegative k, and nonnegative elapsed time, the predicted concentration cannot exceed its initial value and cannot become negative. At t = 0, the answer should equal [A]0. As time increases, the concentration approaches zero mathematically but does not cross it. A result that violates these checks usually points to a unit mismatch, a misplaced reciprocal, or inappropriate input data.
Limits and Common Misinterpretations
A straight-line fit to 1/[A] versus time is evidence for this rate law, not proof that it describes every condition or mechanism. Experimental noise can become more influential when concentrations are transformed by taking reciprocals, so fitting the original kinetic data with an appropriate model may be preferable for careful parameter estimation. The calculator predicts a concentration from the supplied model; it does not determine whether the reaction is actually second order.
Do not use this expression for a first-order reaction, a reaction that is second order in two different reactants, or a system whose rate constant changes significantly over the interval. Catalysts, temperature changes, changing acidity, side reactions, and product inhibition can alter observed kinetics. For bench work, follow your lab method, the safety data sheet (SDS), and your supervisor.
Frequently Asked Questions
What is the second-order rate equation?
For a single reactant A, the differential rate law is −d[A]/dt = k[A]2. The integrated form is 1/[A]t = 1/[A]0 + kt.
What are the units of a second-order rate constant?
For concentration in mol/L and time in seconds, k has units L/(mol·s). The units change if a different concentration or time unit is used.
How do you find the half-life of a second-order reaction?
For the single-reactant law rate = k[A]2, use t1/2 = 1/(k[A]0). The half-life depends on initial concentration.
Is every reaction with a coefficient of 2 second order?
No. Overall reaction coefficients do not generally determine the experimental rate law. Reaction order must be established from kinetic evidence, except where a specific elementary-step mechanism justifies the relationship.
Can I use this equation for rate = k[A][B]?
No. That is a second-order rate law overall, but it involves two reactants. Its integrated treatment depends on their initial concentrations and on whether they begin in equal amounts; this calculator assumes rate = k[A]2.
Related
Formula used
in a | Initial concentration A | mol/L | 0.100 | 0 in k | Rate constant k | L/(mol·s) | 0.50 | 0 in t | Elapsed time | s | 60 | 0 out c | Concentration remaining A | mol/L | 1 / (1 / a + k * t) | 4 out f | Fraction remaining | - | c / a | 4
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Serial Dilution Calculation Examples0.2000 mol/L
- Serial Dilution A Level Biology: How To Do It30
- Serial vs Simple Dilution: Key Differences0.2000 mol/L
- Milton Tablet Dilution: Mixing Guide0.2000 mol/L
- qPCR Serial Dilution Standard Curve: How to Build One100,000 copies/µL
- Serial Dilution Factor: How to Calculate It