The thermal conductivity formula is k = Q·L / (A·ΔT·t), where k is the thermal conductivity, Q is the heat transferred, L is the thickness of the material, A is the cross-sectional area, ΔT is the temperature difference, and t is the time. The SI unit of thermal conductivity is the watt per meter-kelvin (W/(m·K)), sometimes written as W·m⁻¹·K⁻¹.
Formula
The thermal conductivity formula comes from Fourier’s law of heat conduction. In its steady-state form for a flat slab of material, it is written as:
k = (Q × L) / (A × ΔT × t)
Where:
- k = thermal conductivity, in watts per meter-kelvin (W/(m·K))
- Q = amount of heat transferred through the material, in joules (J)
- L = thickness of the material in the direction of heat flow, in meters (m)
- A = cross-sectional area perpendicular to heat flow, in square meters (m²)
- ΔT = temperature difference across the material, in kelvin (K) or degrees Celsius (°C) – the size of one kelvin equals one degree Celsius, so the same number works for both
- t = time over which the heat flows, in seconds (s)
Rearranged, the formula gives the heat flow rate (power) as P = Q/t = k·A·ΔT / L. This is the form most often used in engineering, because it directly gives watts (joules per second).
Worked Example
Let’s use the default values from the calculator: a heat transfer of 500 J, a material thickness of 0.05 m, a cross-sectional area of 0.1 m², a temperature difference of 20 K, and a time of 60 s.
Plug these into the formula:
k = (500 J × 0.05 m) / (0.1 m² × 20 K × 60 s)
First multiply the numerator: 500 × 0.05 = 25 J·m.
Then multiply the denominator: 0.1 × 20 × 60 = 120 m²·K·s.
Now divide: 25 / 120 = 0.20833… W/(m·K).
Rounded to four decimal places, the thermal conductivity is 0.2083 W/(m·K). This is in the range of common insulating materials (for comparison, still air is about 0.026 W/(m·K), wood around 0.1–0.2 W/(m·K), and copper is about 400 W/(m·K)).
Assumptions
- Steady-state heat flow – the temperature at each point does not change with time.
- One-dimensional heat flow – heat moves only through the thickness, not sideways.
- Uniform material – the thermal conductivity is the same throughout the slab.
- Constant thermal conductivity – in reality k varies with temperature, but the formula assumes it is constant over the given range.
- No heat loss from the edges – the area A is the full path for heat flow.
What Thermal Conductivity Actually Measures
Thermal conductivity quantifies how easily heat moves through a material by conduction. A high k means heat flows quickly – metals like silver (about 430 W/(m·K)) and copper (about 400 W/(m·K)) are excellent conductors. A low k means the material resists heat flow – that’s why wool, foam, and air are used as insulators.
The property depends on the material’s internal structure: in metals, free electrons carry heat; in non-metals, heat is transferred by lattice vibrations (phonons). This explains why diamond, a non-metal with strong covalent bonds, has an exceptionally high thermal conductivity of about 900–2300 W/(m·K), higher than most metals.
Thermal conductivity also varies with temperature, pressure, and, for some materials, direction. For example, graphite conducts heat much better along its sheets than perpendicular to them. Wood also shows different values along and across the grain.
How to Measure Thermal Conductivity
There are several standard methods, but they all rely on the same basic principle: create a known heat flow through a sample, measure the temperature difference across it, and apply Fourier’s law.
- Guarded hot plate – a flat sample is sandwiched between a heated plate and a cooled plate. Heat flow is measured from the electrical power supplied, and thermocouples record the temperature drop. This is the standard for insulating materials.
- Heat flow meter – similar to the guarded hot plate, but uses a calibrated heat flux sensor instead of measuring electrical power. It is faster but less accurate.
- Laser flash analysis – a short laser pulse heats one face of a thin disc, and an infrared detector measures the temperature rise on the opposite face. The thermal diffusivity is derived from the time lag, then converted to conductivity using the material’s density and specific heat.
- Transient hot wire – a thin wire embedded in the sample is heated with a constant power, and the temperature rise of the wire over time gives the conductivity. This works well for liquids and powders.
Each method has its own range of applicability and accuracy. For precise work, follow the relevant standard test method (such as ASTM C518 for heat flow meters or ASTM E1461 for laser flash) and your laboratory’s approved procedures.
Common Mistakes and Pitfalls
When using the formula, people often trip on units:
- Mixing centimeters with meters. If you measure thickness in cm, you must convert to meters (divide by 100) before plugging into the formula. Forgetting this changes the result by a factor of 100.
- Using °C vs K. For a temperature difference, the numerical value is the same in °C and K, so this is not a problem. But if you use absolute temperatures in a ratio (like T₁/T₂), you must use kelvin.
- Confusing thermal conductivity (k) with thermal resistance (R-value). Thermal resistance is L/k (in m²·K/W), and it depends on thickness. A thick piece of a good conductor can have a higher R-value than a thin piece of an insulator.
- Forgetting time. The formula uses total heat Q over time t. If you have the heat flow rate in watts (J/s), you can skip the time factor: k = P·L / (A·ΔT).
Thermal Conductivity vs Thermal Diffusivity
People often confuse thermal conductivity with thermal diffusivity. Thermal conductivity (k) measures how well a material conducts heat under steady-state conditions. Thermal diffusivity (α) measures how quickly a temperature change propagates through a material during transient conditions. They are related by:
α = k / (ρ·cp)
Where ρ is density (kg/m³) and cp is specific heat capacity (J/(kg·K)). The unit of thermal diffusivity is m²/s. A material can have high conductivity but low diffusivity if it has high density and specific heat – this is why metals feel cold to the touch (high diffusivity) while a thick ceramic mug stays hot on the outside (lower diffusivity despite decent conductivity).
Frequently Asked Questions
What is the SI unit of thermal conductivity?
The SI unit is the watt per meter-kelvin, W/(m·K). In base SI units, this is kg·m·s⁻³·K⁻¹. Sometimes you’ll see W·m⁻¹·K⁻¹, which is the same thing written with negative exponents.
How do I convert W/(m·K) to W/(m·°C)?
You don’t need to convert. A temperature difference of 1 kelvin is exactly equal to 1 degree Celsius, so the numerical value is identical. For example, 0.6 W/(m·K) is the same as 0.6 W/(m·°C).
What is the thermal conductivity of air?
Dry air at room temperature has a thermal conductivity of about 0.026 W/(m·K). This low value is why trapped air is an excellent insulator – it’s the basis for double-glazed windows, foam insulation, and down jackets.
Why is copper used in heat sinks if silver conducts better?
Silver has a higher thermal conductivity (about 430 W/(m·K) vs copper’s 400 W/(m·K)), but copper is much cheaper and more durable. For most applications, the small difference in performance doesn’t justify the cost of silver, so copper is the standard choice for heat sinks and heat pipes.
Does thermal conductivity change with temperature?
Yes. For most pure metals, conductivity decreases as temperature rises because electrons scatter more. For many insulators and ceramics, conductivity increases with temperature. The change can be significant – for example, the conductivity of steel can vary by 10–20% over a few hundred degrees. Always use the value appropriate for your operating temperature.
What is the difference between thermal conductivity and U-value?
Thermal conductivity (k) is a material property – it doesn’t depend on thickness. The U-value (thermal transmittance) is the overall heat transfer coefficient of a building element (like a wall or window), measured in W/(m²·K). For a single-layer slab, U = k/L. U-value includes surface film resistances and multiple layers, so it’s what you use for whole assemblies.
Safety and Scope
This calculator is for study and engineering planning arithmetic only. It assumes ideal steady-state conditions and does not account for convection, radiation, or contact resistance. When performing actual thermal measurements or designing systems, follow your laboratory’s standard methods, the safety data sheets (SDS) for the materials involved, and the supervision of a qualified engineer or scientist. Always verify that the material’s thermal conductivity is appropriate for the temperature range you are working with.
Related
Formula used
in q | Heat transferred | J | 500 | 0 in l | Thickness (length) | m | 0.05 | 0 in a | Cross-sectional area | m² | 0.1 | 0 in dt | Temperature difference | K | 20 | 0 in t | Time | s | 60 | 0 out k | Thermal conductivity | W/(m·K) | q * l / (a * dt * t) | 4 out r | Thermal resistance (R-value per m) | m·K/W | l / (a * dt) | 4
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- QPP Calculator Canada: How It Works & How to Use It
- PPP Calculator World Bank: How It Works & How to Use It2,000.00
- PPP Calculator: India vs USA Cost Comparison1,000.00 USD
- PPP Calculator USD to INR: How It Works2,335 INR
- PPP Calculator India vs UK: Real Cost Comparison103.63 GBP
- PPP Calculator India vs Dubai: Real Cost Comparison8,954.58 AED