Calculator No. 01-3413 · Updated · Formula and assumptions shown below

Change in volume 1.050 × 10−5 m³
Final volume
0.001011 m³
= Initial volume + Change in volume
Initial volume
0.001 m³
Set in the form below
Volumetric expansion coefficient
0.00021 1/°C
Set in the form below
You enter
Initial volume (m³), Volumetric expansion coefficient (1/°C), Temperature change (°C)
You get
Change in volume (m³), Final volume (m³)
Rounding
6 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

The thermal expansion volume equation is ΔV = βV₀ΔT, where ΔV is the change in volume, β is the volumetric expansion coefficient, V₀ is the starting volume, and ΔT is the temperature change. Enter those three measured or reference values and the coefficient to calculate the volume change; the calculator also gives the final volume, V = V₀ + ΔV.

Formula

The basic equation for volumetric thermal expansion is:

ΔV = βV₀ΔT

  • ΔV is the volume change, in cubic metres (m³).
  • β is the material’s volumetric expansion coefficient, in reciprocal degrees Celsius (1/°C) for a temperature change stated in °C.
  • V₀ is the initial volume, in m³.
  • ΔT is the final temperature minus the initial temperature, in °C.

The resulting volume is V = V₀ + ΔV. A positive ΔT normally gives a positive change for materials with positive β; cooling produces a negative change. The coefficient describes fractional volume change per degree over the temperature range where the approximation is valid.

Worked Example

Using the calculator’s defaults, take an initial volume of 0.001 m³, β = 0.00021 1/°C, and a temperature increase of 50 °C.

First calculate the change:

ΔV = 0.00021 × 0.001 × 50 = 0.0000105 m³

Rounded to the six decimal places shown by the calculator, the change is 0.000011 m³. The unrounded value is retained when calculating the final volume:

V = 0.001 + 0.0000105 = 0.0010105 m³

Rounded to six decimal places, the final volume is 0.001011 m³. The example treats β as constant throughout the 50 °C rise.

Assumptions

  • The material expands uniformly and freely; it is not constrained by a container or surrounding structure.
  • The coefficient β is constant across the stated temperature interval.
  • The input volume is the initial volume at the starting temperature.
  • The equation is a small-change, linear approximation; it does not model phase changes or unusual material behaviour.

How Thermal Expansion Works

Heating generally increases the average separation or motion of a material’s particles, causing its dimensions to change. For an isotropic solid—a material with the same properties in every direction—the linear expansion coefficient α describes the fractional change in length per degree. For modest temperature changes, the volumetric coefficient is approximately β = 3α. This relationship is an approximation, not a universal identity for every material or temperature.

Liquids do not have a fixed shape, so their expansion is usually described directly by a volumetric coefficient. Gases require extra care: their volume depends strongly on pressure as well as temperature. The simple equation applies to a gas only when the relevant pressure conditions support the assumed expansion; for a fixed amount of ideal gas at constant pressure, volume is proportional to absolute temperature, so use kelvins in the gas-law ratio V₂/V₁ = T₂/T₁ rather than treating β as a constant over a large range.

Choosing a Coefficient and Using the Calculator

The coefficient is specific to the material and can vary with temperature, composition, processing, and physical state. Look up a value for the exact material and conditions in a reliable reference or datasheet. The default, 0.00021 1/°C, is an illustrative value close to that used for many common liquids near ordinary temperatures; it is not a universal value for water, oils, or other liquids. For a solid, do not enter a linear coefficient as though it were volumetric: for an isotropic solid, estimate β as about three times α when the small-change approximation is appropriate.

  • Enter the initial volume in m³. Convert litres to cubic metres by dividing by 1,000; convert millilitres by dividing by 1,000,000.
  • Enter β in 1/°C and ΔT as final temperature minus initial temperature. A decrease in temperature is a negative ΔT.
  • Read ΔV as the amount added to or subtracted from the starting volume. Read the second result as the estimated final volume.

A temperature difference has the same numerical size in degrees Celsius and kelvins, so ΔT may be expressed in either unit. Do not use an absolute temperature such as 300 K directly as ΔT; subtract the starting temperature first. The coefficient’s numerical value must match the temperature unit used for the interval.

Limits, Containers, and Common Mistakes

The equation assumes the material can expand without restraint. If a liquid is inside a rigid container, the liquid’s free expansion is not the same as the volume change that actually occurs: pressure can rise, the container can deform, or a relief system may affect the outcome. A real design calculation must account for container expansion, mechanical constraints, pressure limits, and the relevant material data.

For large temperature changes, β may change enough that one constant coefficient gives a poor estimate. More generally, if β varies with temperature, the volume change is found from ΔV = V₀∫β(T)dT across the temperature interval, with appropriate material data. Phase transitions, boiling, freezing, and changes in material structure cannot be represented by the simple linear equation. Near such transitions, use data or a model specific to the substance and conditions.

  • Mixing up α and β: α describes length expansion; β describes volume expansion.
  • Using the wrong starting volume: V₀ must correspond to the initial temperature, not the final state.
  • Forgetting the sign: cooling has negative ΔT and normally predicts contraction.
  • Using mismatched units: a coefficient per kelvin is compatible with a temperature difference in kelvins or Celsius degrees, but volume units must also agree.
  • Overinterpreting rounded output: rounding can hide a small change. Keep unrounded values for intermediate calculations when precision matters.

Frequently Asked Questions

What is the equation for volume thermal expansion?
For a constant volumetric expansion coefficient, use ΔV = βV₀ΔT. Add ΔV to the initial volume to estimate the final volume.

What does β mean in the equation?
β is the volumetric expansion coefficient: the approximate fractional change in volume per degree of temperature change. Its value depends on the material and conditions.

Can I use Celsius instead of kelvins?
Yes, for ΔT: a change of 1 °C equals a change of 1 K. Use a temperature difference, not an absolute temperature, and express β in reciprocal units that match that difference.

How do I calculate the final volume?
Calculate ΔV = βV₀ΔT, then use V = V₀ + ΔV. Keep the same volume units throughout.

Is the volume expansion coefficient three times the linear coefficient?
For an isotropic solid and a modest temperature change, β is approximately 3α. The relationship may not hold for anisotropic materials or over broad temperature ranges.

Does this equation work for gases?
Only with suitable conditions and a coefficient valid for the range. For a fixed amount of ideal gas at constant pressure, the more appropriate relation is V₂/V₁ = T₂/T₁ with absolute temperatures in kelvins.

Related

Formula used
in v0 | Initial volume | m³ | 0.001 | 0
in beta | Volumetric expansion coefficient | 1/°C | 0.00021 | 0
in dt | Temperature change | °C | 50 | -
out dv | Change in volume | m³ | beta * v0 * dt | 6
out vf | Final volume | m³ | v0 + dv | 6

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →