The equation m1v1 = m2v2 is the dilution formula, used to calculate how to dilute a stock solution to a lower concentration by adding solvent. It states that the product of the initial molarity (m1) and initial volume (v1) equals the product of the final molarity (m2) and final volume (v2), because the amount of solute stays constant during dilution.
Formula
The dilution equation is written as:
m1 × v1 = m2 × v2
Where:
- m1 = initial molarity (mol/L, often written M)
- v1 = initial volume (L or mL, as long as both volumes use the same unit)
- m2 = final molarity (mol/L)
- v2 = final volume (same unit as v1)
The equation works because moles of solute = molarity × volume (in liters). When you dilute, you add solvent but not solute, so the moles before and after are equal: m1v1 = m2v2.
Worked Example
Suppose you have a 5.00 M NaCl stock solution and you want to prepare 250 mL of a 0.200 M solution. What volume of stock do you need?
Using m1v1 = m2v2:
m1 = 5.00 M, v1 = ?, m2 = 0.200 M, v2 = 250 mL
v1 = (m2 × v2) / m1 = (0.200 × 250) / 5.00 = 50.0 / 5.00 = 10.0 mL
So you take 10.0 mL of the 5.00 M stock and add enough water to reach a final volume of 250 mL. The result is 0.200 M NaCl.
Now check with the calculator above: if you instead start from solid NaCl, to make 250 mL of 0.200 M solution, you need mass = molarity × volume × molar mass = 0.200 × (250/1000) × 58.44 = 2.922 g. That matches the default in the calculator.
Assumptions
- Molarity is used (moles per liter), not molality or mass percent.
- The volumes are additive – in practice, you mix to a final volume, not by adding a set amount of solvent.
- Temperature is constant – molarity changes slightly with temperature because volume changes.
- The solute is non-volatile and does not react with the solvent.
When to Use the Dilution Equation
The m1v1 = m2v2 formula is used in any lab where a concentrated stock solution is diluted to a working concentration. Common applications include:
- Preparing a series of standards for a calibration curve (e.g., 0.1, 0.2, 0.5 M)
- Diluting a commercial acid or base (like 12 M HCl) to a safer 1 M solution
- Making buffer solutions from a 10× stock
- Diluting a protein or dye solution for spectrophotometry
It only applies when you are diluting with solvent – not when you are mixing two different solutes or when a chemical reaction occurs.
How to Choose Which Variable to Solve For
You can rearrange the equation to solve for any one of the four variables:
- To find final concentration: m2 = (m1 × v1) / v2
- To find initial volume needed: v1 = (m2 × v2) / m1
- To find final volume: v2 = (m1 × v1) / m2
- To find initial concentration: m1 = (m2 × v2) / v1
Always check that your units match: if you use mL for v1 and v2, the equation still works because the units cancel. If you mix L and mL, you will get a wrong answer.
Common Mistakes and Misconceptions
One common error is adding the solvent volume instead of the final volume. For example, if you need 250 mL of a diluted solution, you do not add 250 mL of water to the stock; you add enough water to make the total volume 250 mL. That means you add (250 – volume of stock) mL of water.
Another mistake is using the equation for serial dilutions incorrectly. In a serial dilution, you dilute a portion of the previous solution, so you apply the equation step by step, not all at once.
A frequent misconception is that m1v1 = m2v2 works for any concentration unit. It works for molarity (mol/L) and for any unit where concentration × volume gives the amount of solute (e.g., normality, but not for mass percent unless you adjust). For mass/volume percent (like w/v), the equation still works if you keep the same unit of mass per volume.
Comparison with Other Dilution Methods
There are other ways to express dilution:
- Dilution factor = final volume / aliquot volume (e.g., a 1:10 dilution means 1 part stock + 9 parts solvent)
- C1V1 = C2V2 – the same equation, just written with C for concentration
- Serial dilution – repeated dilutions, each using the previous solution as the new stock
The equation m1v1 = m2v2 is the most direct way to calculate a single dilution. For serial dilutions, you apply it repeatedly.
Practical Lab Tips
When preparing a dilution in the lab:
- Use a volumetric flask for the final volume – it is more accurate than a graduated cylinder.
- Add the stock solution first, then add solvent up to the mark.
- Mix thoroughly after dilution.
- Record the exact concentrations and volumes in your notebook.
- If you are working with a strong acid or base, always add acid to water, not water to acid, and follow your lab method and the safety data sheet (SDS).
Frequently Asked Questions
What does m1v1 = m2v2 actually mean?
It means the number of moles of solute before dilution equals the number of moles after dilution. Molarity times volume gives moles, so if you change the volume, the concentration changes inversely to keep the product constant.
Can I use m1v1 = m2v2 with volumes in mL?
Yes, as long as both volumes use the same unit. The equation is a ratio, so mL on both sides cancels. Just don’t mix mL and L in the same equation.
Why is it not m1v1 = m2v2 for mass percent?
It actually works for mass percent (w/w) if you use mass of solution instead of volume, but the common form uses volume. For w/v percent (g/mL), it works too because concentration × volume gives mass of solute.
What is the difference between dilution and concentration?
Dilution adds solvent to lower concentration; concentration removes solvent to raise concentration. The same equation can be used for concentration if you know the final volume, but in practice you often use evaporation, which changes volume in a non-linear way.
How do I calculate serial dilutions?
For a serial dilution, apply m1v1 = m2v2 step by step. For example, to make a 1:10 dilution, take 1 mL of stock and add 9 mL of solvent to get 10 mL. Then take 1 mL of that and add 9 mL to get a 1:100 dilution, and so on.
Does temperature affect the dilution equation?
Yes, because molarity depends on volume, and volume changes with temperature. The equation assumes constant temperature. For precise work, prepare solutions at the temperature you will use them, or use molality instead.
Related
Formula used
in m | Mass of solute | g | 2.922 | 0 in mm | Molar mass | g/mol | 58.44 | 0.001 in v | Final solution volume | mL | 250 | 0.001 out c | Molarity | mol/L | m / mm / (v / 1000) | 4 out cmm | Concentration in millimolar | mM | c * 1000 | 2
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Normality to meq/mL Conversion Calculator1.0000 meq/mL
- Normality to g/L Converter & Formula29.220 g/L
- Normality Test Q-Q Plot: How to Read It
- Normality Test Results: How to Analyze Them
- Normality Slay the Spire?
- Normality Test for Paired t Test: How to Check