This calculator estimates the concentration of a reactant remaining after a specified time when its disappearance follows first-order kinetics. Enter the initial concentration, the first-order rate constant, and elapsed time; it returns the remaining concentration and the corresponding half-life.
Formula
For a reactant A disappearing by a first-order process, its concentration at time t is:
[A]t = [A]0 e−kt
- [A]t is the concentration remaining at time t, in mol/L.
- [A]0 is the initial concentration at t = 0, in mol/L.
- k is the first-order rate constant, in s−1 for the calculator’s time units.
- t is elapsed time, in seconds.
- e is the base of the natural logarithm.
The calculator also gives the half-life, the time required for the concentration to fall to half its initial value: t1/2 = ln(2)/k. Here ln(2) is approximately 0.693147. The rate constant and time units must match: if k is entered in s−1, time must be in seconds. The formula assumes k is constant over the interval.
Worked Example
Using the calculator defaults, [A]0 = 0.100 mol/L, k = 0.002 s−1, and t = 600 s:
Exponent: −kt = −(0.002 s−1)(600 s) = −1.2.
[A]t = (0.100 mol/L)e−1.2 = 0.030119421 mol/L, which rounds to 0.0301 mol/L.
Half-life: t1/2 = ln(2)/(0.002 s−1) = 346.57359 s, which rounds to 346.57 s.
Assumptions
- The process follows a single first-order rate law over the stated interval.
- The rate constant does not change with time; temperature and other relevant conditions are treated as constant.
- The entered concentration is the concentration of the reacting species, and the calculation does not model changing volume, competing reactions, or measurement uncertainty.
What First-Order Kinetics Means
First-order kinetics describes a rate that is directly proportional to the concentration of one reacting species. For the disappearance of A, the differential rate law is −d[A]/dt = k[A]. The minus sign indicates that A is being consumed, while the positive rate constant k sets the speed of the process. Double [A] while holding conditions fixed, and the instantaneous disappearance rate doubles.
“First order” refers to the exponent on concentration in the rate law; it does not mean the reaction is necessarily a single step, especially fast, or chemically simple. In a multistep reaction, the observed rate law must be determined experimentally or derived from a justified mechanism. A balanced chemical equation alone generally does not establish reaction order.
How to Read the Result
First-order loss is exponential, not a fixed amount removed per unit time. Equal time intervals remove equal fractions of the amount then present. After one half-life, half remains; after two half-lives, one quarter remains; after three, one eighth remains. The concentration approaches zero mathematically but does not reach zero at a finite time under this ideal equation.
The rate constant has units of inverse time, such as s−1, min−1, or h−1. Its numerical value is meaningful only alongside its units and conditions. A larger k means faster disappearance and a shorter half-life. For example, if k is reported in min−1, convert elapsed seconds to minutes or convert k to s−1 before using the equation; do not combine unlike time units.
Recognizing First-Order Behavior
Experimental data can be checked against the integrated rate law. Taking natural logarithms gives ln[A]t = ln[A]0 − kt. If measured ln(concentration) plotted against time forms an approximately straight line, its slope is −k and its intercept is ln[A]0. The fit should be assessed across the relevant range, with measurement uncertainty and possible alternative rate laws considered.
A related diagnostic is the half-life. For a first-order process it is independent of the starting concentration under constant conditions. If successive half-lives differ substantially, that can indicate changing conditions, measurement limits, multiple processes, or a rate law that is not first order. It is not conclusive by itself: noisy or sparse measurements can obscure the pattern.
Comparisons and Common Mistakes
For zero-order disappearance, the rate is constant and concentration falls linearly with time; its half-life depends on the initial concentration. For a simple second-order law, the rate depends on concentration squared and the integrated relationship differs. These patterns are useful comparisons, but real reactions can have more complicated kinetics.
- Confusing order with stoichiometry: reaction coefficients do not automatically give the rate-law exponents. Establish the rate law from data or a supported mechanism.
- Mixing units: multiplying k in min−1 by time in seconds gives the wrong exponent. Convert both to a common time unit.
- Misreading half-life: it is the time for half of the amount present to remain, not a guarantee that the same fixed quantity disappears each interval.
- Assuming all decay is first order: the equation is a model. Check whether observations follow it under the conditions of interest.
- Rounding too early: keep unrounded intermediate values where possible, then round the reported result to match the precision justified by the inputs.
For bench work, follow your lab method, the safety data sheet (SDS), and your supervisor. This calculator is for study and lab-planning arithmetic, not a substitute for validated experimental analysis.
Frequently Asked Questions
What is the equation for first-order kinetics?
The integrated equation is [A]t = [A]0e−kt. It predicts the concentration remaining from the initial concentration, rate constant, and elapsed time.
What are the units of a first-order rate constant?
They are inverse time, such as s−1 or min−1. Use the matching time unit in the calculation so kt is dimensionless.
How do you calculate first-order half-life?
Use t1/2 = ln(2)/k. For a constant first-order rate constant, the half-life does not depend on the starting concentration.
Does first order mean one molecule is involved?
No. It describes how the observed rate depends on concentration, not the number of molecules in the overall reaction or its mechanism.
How can I tell if a reaction is first order?
One check is whether ln(concentration) versus time is linear over the data range, with slope approximately −k. Also consider experimental uncertainty and whether conditions stayed constant.
Related
Formula used
in c0 | Initial concentration | mol/L | 0.100 | 0 in k | First-order rate constant | 1/s | 0.002 | 0 in t | Elapsed time | s | 600 | 0 out c | Concentration remaining | mol/L | c0 * exp(-k * t) | 4 out th | Half-life | s | ln(2) / k | 2
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Serial Dilution Calculation Examples0.2000 mol/L
- Serial Dilution: How It Works & Why It Matters1.000 × 10−5 mol/L
- Serial Dilution A Level Biology: How To Do It30
- Serial vs Simple Dilution: Key Differences0.2000 mol/L
- Milton Tablet Dilution: Mixing Guide0.2000 mol/L
- qPCR Serial Dilution Standard Curve: How to Build One100,000 copies/µL