Calculator No. 01-6555 · Updated · Formula and assumptions shown below

Rate constant k 0.1000 L/mol/s
Reaction rate
0.002 mol/(L*s)
Set in the form below
Concentration of A
0.1 mol/L
Set in the form below
Concentration of B
0.2 mol/L
Set in the form below
Order with respect to A
1
Set in the form below
You enter
Reaction rate (mol/(L*s)), Concentration of A (mol/L), Concentration of B (mol/L), Order with respect to A, Order with respect to B
You get
Rate constant k (L/mol/s)
Rounding
4 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

This kinetics calculator works out the rate constant, k, from a measured reaction rate and reactant concentrations using a stated rate law. Enter the rate, concentrations, and reaction orders; the result is k with its units. A rate law must be known or experimentally determined first—reaction orders cannot generally be inferred from the balanced equation.

Formula

For a rate law of the form rate = k[A]m[B]n, rearrange to calculate k = rate / ([A]m[B]n). Here, “rate” is the reaction rate in mol L−1 s−1; [A] and [B] are concentrations in mol L−1; m and n are the respective reaction orders, dimensionless; and k is the rate constant. The output unit shown here, L mol−1 s−1, applies to an overall second-order rate law (m + n = 2). In general, the unit of k depends on the overall order and on the units used for rate and concentration.

Worked Example

Using the defaults: rate = 0.002 mol L−1 s−1, [A] = 0.1 mol L−1, [B] = 0.2 mol L−1, and m = n = 1:

k = 0.002 / (0.11 × 0.21) = 0.002 / 0.020 = 0.1000 L mol−1 s−1.

Assumptions

  • The entered rate law applies to the reaction and conditions being analyzed.
  • Rate and concentrations use the units stated in the calculator.
  • The listed output unit presumes an overall second-order rate law; use dimensional analysis to state the unit for other orders.
  • For bench work, follow your lab method, the safety data sheet (SDS) and your supervisor.

What k Means in a Rate Law

In chemical kinetics, k is the rate constant: the proportionality factor in a specified rate law. For example, if experiments establish rate = k[A][B], then doubling [A] while holding [B] fixed doubles the rate, and k is the factor connecting those concentrations to the measured rate. The letter is a conventional symbol, not a word or slang term. It is commonly read aloud as “kay” and written in equations as lowercase italic k.

The constant is not a universal number for a chemical reaction under every condition. Its value is associated with a particular reaction mechanism or empirical rate law, temperature, solvent, and other relevant conditions. In many reactions, changing temperature changes k substantially. A catalyst can also change the reaction pathway and the observed rate constant, while not changing the reaction’s overall stoichiometric equation.

Reaction Order and the Units of k

Reaction orders are the exponents in the experimentally supported rate law. For rate = k[A]m[B]n, the overall order is m + n. If m = 1 and n = 1, the law is second order overall. If the law is rate = k[A], it is first order; if rate = k[A]2, it is second order in A. Orders can be zero, fractional, or negative in some empirical laws; they are not automatically the stoichiometric coefficients of the balanced reaction.

Units follow from the equation. Concentration is commonly expressed in mol L−1 and rate in mol L−1 s−1. For an overall order q, the resulting unit of k is (mol L−1)1−q s−1. Thus a first-order k has units s−1, while a second-order k has units L mol−1 s−1. A zero-order k has the same units as rate. Always derive the units from the specific rate law rather than memorizing one unit for all k values.

How k Is Determined and Used

The calculator rearranges a rate law to find k from one measured rate and the concentrations at that measurement. It is useful only when the rate law and orders are already available—for example, from an experiment or a properly supported reference for the same system. To determine orders experimentally, chemists compare initial rates while varying reactant concentrations, or analyze concentration-versus-time data with an appropriate kinetic model.

  • Write the rate law, including each reactant exponent.
  • Use the concentrations corresponding to the measured rate, not initial concentrations unless the measured rate is an initial rate.
  • Enter compatible units and calculate k using the equation.
  • Repeat with additional measurements. Consistent k values support the chosen law under those conditions; systematic differences may signal measurement issues or an inadequate model.

For instance, under rate = k[A][B], the defaults give k = 0.1000 L mol−1 s−1. If the measured rate doubles while both concentrations remain unchanged, the calculated k would also double. That would not by itself mean the true rate constant changed: it could indicate experimental variation, changed conditions, or that the entered rate law does not describe the data.

Common Misunderstandings and Limits

A frequent misconception is that k is the reaction rate. It is not: the rate changes as concentrations change, whereas k is the proportionality constant for the specified rate law at specified conditions. Another is that k is always the same for a reaction regardless of temperature. Temperature dependence is a central feature of kinetics; comparisons require conditions to be stated.

Be especially careful with orders and units. Entering a concentration in mmol/L as though it were mol/L changes the numerical result. Likewise, a rate reported per minute cannot be combined directly with concentrations to produce a per-second rate constant. Convert consistently before calculation. The calculator’s displayed unit assumes a total order of two; for other orders, the numerical expression still follows the entered law, but the unit label must be adjusted by dimensional analysis.

The simple power-law form may not fit every reaction, especially when mechanisms involve intermediates, inhibition, reversible steps, or changing conditions. In such cases, a more detailed kinetic model may be needed. The calculator does not determine a rate law, account for uncertainty, or establish a mechanism; it evaluates the formula supplied by the user.

Frequently Asked Questions

What does k stand for in chemical kinetics?
It denotes the rate constant in a specified rate law. It relates reactant concentrations to the measured reaction rate under stated conditions.

Is k the same as the reaction rate?
No. The reaction rate is the observed change in concentration per time. k is a factor in the rate law, and its units depend on the law’s overall order.

Does k change when concentration changes?
For a fixed rate law at fixed conditions, k does not ordinarily change simply because reactant concentration changes. The rate changes according to the concentration terms. Different conditions or a different effective mechanism can change the applicable k.

How do I find k from a rate law?
Rearrange the law to isolate k. For rate = k[A]m[B]n, divide the measured rate by [A]m[B]n, using consistent units and the correct orders.

Can I get reaction order from the balanced equation?
Not generally. Orders are usually determined from experimental kinetic data; they equal stoichiometric coefficients only in particular elementary-step rate laws, not as a general rule.

Why does k have different units in different problems?
Because k must make the rate law’s units balance. Its units depend on the overall reaction order and on the units selected for concentration and time.

Related

Formula used
in r | Reaction rate | mol/(L*s) | 0.002 | 0
in a | Concentration of A | mol/L | 0.1 | 0
in b | Concentration of B | mol/L | 0.2 | 0
in m | Order with respect to A | - | 1 | 0
in n | Order with respect to B | - | 1 | 0
out k | Rate constant k | L/mol/s | r / (a^m * b^n) | 4

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work