The decay equation describes how a quantity decreases over time when its rate of loss is proportional to how much remains. This calculator works out the remaining amount from an initial quantity, a decay constant and elapsed time; it also gives the fraction remaining and the half-life.
Formula
For continuous exponential decay, the remaining quantity is the initial quantity multiplied by an exponential factor:
N(t) = N0e−kt
- N(t) is the quantity remaining after time t, in the same units as the initial quantity.
- N0 is the quantity at the starting time.
- k is the decay constant, with units inverse to the time unit used (for example, s−1 when time is in seconds).
- t is elapsed time, in seconds for the calculator’s stated input convention.
- e is the mathematical constant approximately 2.71828.
The matching differential equation is dN/dt = −kN: the rate of change is negative and proportional to the amount present. The fraction remaining is N(t)/N0 = e−kt. The half-life is t1/2 = ln(2)/k, the time required for the quantity to fall to half its starting value.
This calculator uses seconds for t and s−1 for k. For another time unit, use a decay constant expressed per that same unit, or convert consistently before entering values. For example, a constant in min−1 must be paired with time in minutes; do not enter it as though it were s−1.
Worked Example
Using the calculator’s defaults, the initial quantity is 100 units, the decay constant is 0.01 s−1, and elapsed time is 60 s.
- Calculate the dimensionless exponent: −kt = −(0.01 s−1)(60 s) = −0.6.
- Evaluate the exponential factor: e−0.6 ≈ 0.54881.
- Multiply by the initial amount: N(60) = 100 × 0.5488116… ≈ 54.88 units.
The fraction remaining is approximately 0.5488, or 54.88%. The half-life is ln(2)/0.01 s−1 = 69.31 s. The remaining amount and fraction are rounded to the calculator’s displayed precision.
Assumptions
- The decay constant is constant throughout the time interval.
- The process follows a continuous, first-order exponential model.
- The input amount is nonnegative, the decay constant is nonnegative, and elapsed time is nonnegative.
- The time unit used for elapsed time matches the inverse time unit of the decay constant; the calculator’s example uses seconds and s−1.
What the Decay Equation Means
“Decay equation” is a descriptive name for equations that model a decrease, not the name of one uniquely defined equation in every field. The exponential form above is the standard first-order model used when a constant fraction of the remaining amount is lost per unit time. It applies to radioactive decay under the usual model, and also to other processes that meet the same mathematical condition, such as a simplified model of a substance disappearing from a system.
The word decay comes through Old French and Latin roots associated with falling away or diminishing. In science, it refers broadly to a decrease or transformation. The particular equation must be chosen from the process: linear loss, exponential decay and more complex kinetics are not interchangeable.
How to Use It and Read the Result
Enter the starting quantity and its unit, the decay constant and its unit, and the elapsed time. The first result is the predicted quantity remaining. Its unit is inherited from the initial quantity: if the input is 100 grams, a result of 54.88 means 54.88 grams. The fraction output has no unit and can be multiplied by 100 to express a percentage.
The decay constant is not itself a percentage unless a specific time interval and convention are stated. A value of 0.01 s−1 means the instantaneous proportional loss rate is 0.01 per second in this model; it does not mean that exactly 1% disappears during every one-second interval. The exponential equation accounts for continuous change.
- Use a measured or otherwise justified decay constant for the process being modeled.
- Keep time and the decay constant’s units consistent.
- For a half-life rather than a decay constant, convert with k = ln(2)/t1/2.
- Use the result as a model prediction, not as a substitute for measurements when actual conditions matter.
Common Confusions and Model Limits
A frequent mistake is to treat “decay” as always meaning radioactive decay. The same mathematical form can describe other first-order losses, but the parameters and physical interpretation depend on the subject. For radioactive decay, N may represent the number of undecayed nuclei, and k is the nuclide-specific decay constant. The equation predicts a population-level expectation; the decay of an individual nucleus is random.
Another common error is mixing units. If a half-life is reported in hours, then k calculated from it is in h−1. Pairing that constant with seconds without conversion produces a wrong answer. Rounding too early can also shift later calculations, so retain precision through intermediate steps and round only the reported result.
The simple equation is not appropriate when the rate changes over time, the process is not first-order, material enters the system, or multiple interacting processes control the amount. Some fields use “decay equation” for a different relationship, including equations for damped motion or changing signals. In those cases, identify the variable, governing law and assumptions before using a formula.
For radioactive material or other laboratory work, calculations alone do not establish that an activity or procedure is safe. Follow your lab method, the safety data sheet (SDS) and your supervisor.
Frequently Asked Questions
What is the basic decay equation?
The standard first-order exponential form is N(t) = N0e−kt, where the quantity remaining falls exponentially with elapsed time.
How do I calculate decay from half-life?
Convert the half-life to a decay constant using k = ln(2)/t1/2, then use that constant in the decay equation. Keep the time units consistent.
What does the decay constant mean?
It is the proportional rate parameter for a first-order process. Its units are the inverse of time, such as s−1 or h−1; a larger value means faster decay.
Is decay always exponential?
No. Exponential decay applies when the rate of decrease is proportional to the amount remaining and the proportionality constant stays fixed. Other processes may follow different equations.
What is the difference between decay constant and half-life?
The decay constant describes the rate in inverse-time units, while half-life is a duration. For exponential decay they are related by t1/2 = ln(2)/k.
Related
Formula used
in n0 | Initial quantity | units | 100 | 0 in k | Decay constant | 1/s | 0.01 | 0 in t | Elapsed time | s | 60 | 0 out n | Remaining quantity | units | n0 * exp(-k * t) | 4 out f | Fraction remaining | - | exp(-k * t) | 4 out th | Half-life | s | ln(2) / k | 2
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Calculator in Hindi: Meaning, Usage and Examples0.2000 mol/L
- Volume Strength Formula in Terms of Molarity11.20 volumes
- H2O2 Volume Strength to Molarity Calculator0.893 mol/L
- Volume Strength to Molarity: Formula and Calculator0.0409 mol/L
- Molar Volume: Definition, Formula, and Calculator22.414 L/mol
- Molar Volume of a Gas Calculator and Formula22.4140 L/mol