molecalculator

Moles & Molar Mass

Decay Formula: Exponential Decay and Half-Life

Calculator No. 01-4544 · Updated · Formula and assumptions shown below

Amount remaining 36.79 amount units
Fraction remaining
0.3679
Result, rounded to 4 decimal places
Half-life
6.93 time units
Result, rounded to 2 decimal places
Starting amount
100 amount units
Set in the form below
You enter
Starting amount (amount units), Decay constant (1/time unit), Elapsed time (time units)
You get
Amount remaining (amount units), Fraction remaining, Half-life (time units)
Rounding
2 dp · 4 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

This calculator works out the amount of a substance remaining after a chosen time when it decays exponentially at a constant rate. Enter the starting amount, elapsed time, and decay constant; it returns the remaining amount, the fraction left, and the half-life implied by that constant.

Formula

For a process with a constant first-order decay rate, the amount remaining is N(t) = N0e−kt. Here, N(t) is the amount remaining at time t, in the same amount units as the starting value; N0 is the initial amount; k is the decay constant, expressed as the inverse of the chosen time unit; t is elapsed time in that same time unit; and e is the base of natural logarithms. The formula describes a continuous decrease, not a fixed subtraction per time interval.

The calculator also reports the remaining fraction, f = e−kt, which has no units, and the half-life, t1/2 = ln(2)/k. The half-life is the time for the amount to fall to one-half its starting value. The time units used for k and t must match: if k is in day−1, t must be entered in days and the half-life is in days. This calculator treats the entered amount as an arbitrary consistent quantity, such as grams, moles, or number of atoms; it does not infer which substance is involved.

Worked Example

Using the calculator’s defaults, N0 = 100 amount units, k = 0.1 per time unit, and t = 10 time units:

  1. Calculate the exponent: −kt = −(0.1)(10) = −1.
  2. Find the remaining fraction: f = e−1 = 0.3678794412, displayed to four decimal places as 0.3679.
  3. Find the remaining amount: N(t) = 100 × e−1 = 36.78794412 amount units, displayed to two decimal places as 36.79 amount units.
  4. Find the half-life: t1/2 = ln(2)/0.1 = 6.931471806 time units, displayed as 6.93.

The headline result is therefore 36.79 amount units remaining. The fraction means about 36.79% of the initial amount remains after 10 time units; the half-life is shorter than the elapsed time, so the remaining amount is below one-half.

Assumptions

  • The decay follows a single first-order exponential model with a constant k over the full interval.
  • The starting amount is nonnegative, and the decay constant is nonnegative. A zero constant means no decay; in that case the half-life is undefined, so a half-life result should not be interpreted when k is zero.
  • The units of k and t are reciprocal and matching, respectively; the amount unit itself cancels in the fraction calculation.
  • This is study and planning arithmetic, not a measurement of a particular sample. Real observations may be affected by uncertainty, changing conditions, or more than one decay process.

What “decay formula” means

“Decay formula” is a general descriptive phrase, not one unique equation used in every subject. It commonly refers to an exponential model for radioactive decay, but exponential decrease also appears in chemical kinetics, cooling models, electrical systems, and other processes. The appropriate equation depends on what is decreasing and on the assumptions about its rate.

For radioactive decay of a population of unstable nuclei, N can represent the expected number of undecayed nuclei. The same equation is often written N = N0e−λt, using λ for the decay constant. Some textbooks instead write N = N0(1/2)t/t1/2. These are equivalent when k = λ = ln(2)/t1/2. The calculator uses k to make clear that the constant is tied to the selected time unit.

Radioactive decay is random for individual nuclei: the equation predicts the average behavior of a large population, not the exact moment a particular nucleus will decay. Likewise, a measured sample can fluctuate around the expected count, especially when few nuclei remain.

How to use and interpret the result

Choose one time unit and use it consistently. For example, with k = 0.05 day−1, enter elapsed time in days. If the elapsed time is instead supplied in hours, convert either the time to days or the rate to hour−1 before using the formula. The number 0.05 is not meaningful by itself without its inverse-time unit.

The output is the model’s predicted amount, not necessarily a directly measurable quantity. If the starting value is 100 grams, for example, the output is in grams; if it is 100 atoms in an abstract exercise, the output is an expected count and may be fractional because it is a mathematical expectation. The fraction output makes comparisons independent of the starting amount.

  • If kt = 0, the model gives f = 1: none of the initial amount has decayed.
  • If kt = ln(2), the model gives f = 0.5: one half-life has elapsed.
  • If kt is much larger than 1, very little remains; rounding may display the result as zero even though the mathematical value is positive.

Common mistakes and model limits

The most common error is mixing units, such as combining a rate per year with a time in days. Another is treating the decay constant as a half-life: k and t1/2 are related, but they are not interchangeable. Convert a known half-life using k = ln(2)/t1/2, or calculate the half-life from a known k.

Do not confuse the decay constant with the fraction lost. Over a finite interval, the fraction that decays is 1 − e−kt, not generally kt. The approximation 1 − e−kt ≈ kt is useful only when kt is small. For longer intervals, use the full exponential expression.

The simple equation assumes a constant first-order rate and one relevant process. It may not describe a system where the rate changes, where material is added or removed, where several components decay at different rates, or where the observed quantity is governed by a different kinetic order. In a radioactive decay chain, a daughter product may itself decay, requiring coupled equations rather than a single exponential. Use measured data and a model suited to the system when those effects matter.

The result also does not include measurement uncertainty, background signal, or detection limits. A calculated amount below an instrument’s detection limit does not mean the amount is exactly zero. In laboratory work, follow your lab method, the safety data sheet (SDS), and your supervisor.

Frequently Asked Questions

What is the basic decay formula?
The standard first-order exponential form is N(t) = N0e−kt, where N0 is the initial amount, k is the decay constant, and t is elapsed time in matching units.

How do I calculate decay from half-life?
Use N(t) = N0(1/2)t/t1/2. Equivalently, set k = ln(2)/t1/2 and use the exponential formula. Keep t and the half-life in the same time unit.

How do I find the decay constant?
If you know the half-life, calculate k = ln(2)/t1/2. If you have two positive amount measurements, N0 and N(t), then k = ln(N0/N(t))/t, provided the process fits a constant first-order model.

What is the difference between decay constant and half-life?
The decay constant gives the rate of exponential decrease per unit time; the half-life gives the time required for half the amount to remain. They are related by t1/2 = ln(2)/k.

Can the decay formula give a fractional number of atoms?
Yes. It gives the expected value for a population, which can be fractional mathematically. An actual measured count is a whole number and may differ from that expectation because individual decay events are random.

Related

Formula used
in n0 | Starting amount | amount units | 100 | 0
in k | Decay constant | 1/time unit | 0.1 | 0
in t | Elapsed time | time units | 10 | 0
out n | Amount remaining | amount units | n0 * exp(-k * t) | 2
out f | Fraction remaining | - | exp(-k * t) | 4
out h | Half-life | time units | ln(2) / k | 2

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →