For a zero-order reaction, a graph of reactant concentration [A] against time is a straight line whose slope is −k; its y-intercept is the starting concentration [A]₀. This calculator uses [A]₀, the zero-order rate constant k, and elapsed time t to find the remaining concentration, the time to reach a specified concentration, and the half-life.
Formula
The integrated zero-order rate law is [A]ₜ = [A]₀ − kt. Here, [A]ₜ is reactant concentration after time t, in mol/L; [A]₀ is initial concentration, in mol/L; k is the zero-order rate constant, in mol/(L·s); and t is elapsed time, in seconds. For a plot of [A] against t, the slope is −k and the y-intercept is [A]₀. The half-life is t1/2 = [A]₀/(2k). Rearranging the integrated law gives the time to a target concentration, t = ([A]₀ − [A])/k.
The calculator requires consistent units. If time is entered in seconds, k must be expressed per second; for time in minutes, convert k to mol/(L·min) or convert the time to seconds. Concentration and k must use matching concentration units. The concentration calculation flags cases where kt exceeds [A]₀, and the target-time calculation flags a target above the starting concentration rather than reporting a negative time. A target below zero is outside the physical concentration range.
Worked Example
Using the defaults, [A]₀ = 0.100 mol/L, k = 0.001 mol/(L·s), t = 40 s, and target [A] = 0.050 mol/L:
- Concentration after 40 s: [A]ₜ = 0.100 − (0.001 × 40) = 0.06000 mol/L.
- Graph slope: −k = −0.00100 mol/(L·s).
- Graph y-intercept: [A]₀ = 0.1000 mol/L.
- Half-life: 0.100/(2 × 0.001) = 50.0000 s.
- Time to reach 0.050 mol/L: (0.100 − 0.050)/0.001 = 50.0000 s.
Assumptions
- The reaction follows zero-order kinetics over the time interval being considered.
- Concentration is uniform and measured in mol/L; k is constant and uses seconds as its time basis.
- The linear law is used only while reactant remains; it does not describe negative concentrations or later behavior after depletion.
- This is study and lab-planning arithmetic, not a substitute for experimental measurement. For bench work, follow your lab method, the safety data sheet (SDS), and your supervisor.
What a Zero-Order Kinetics Graph Shows
“Zero order” describes how the reaction rate depends on the concentration of the reactant in the rate law. For one reactant, the rate is independent of [A] over the conditions where the zero-order model applies: −d[A]/dt = k. The negative sign indicates that reactant concentration falls; k itself is conventionally positive. Integrating this constant rate gives the straight-line equation used above.
To identify the characteristic graph, put time on the horizontal axis and [A] on the vertical axis. A reasonably straight descending line supports zero-order behavior over the measured interval. Its gradient is −k, and extrapolating the line to t = 0 gives [A]₀. A graph of ln[A] against time is instead linear for a first-order reaction; a graph of 1/[A] against time is linear for a second-order reaction with the usual single-reactant rate law. Graph choice matters: a curved plot is not made linear simply by calling the reaction zero order.
How to Read the Rate Constant and Half-Life
The units of k depend on the order of the reaction. For zero order, concentration is lost per unit time, so a common unit is mol L⁻¹ s⁻¹. The slope has these same units. A steeper downward slope means concentration decreases faster under the conditions represented by that graph. Do not compare numerical k values without checking both their units and the experimental conditions.
Unlike the first-order half-life, the zero-order half-life depends on starting concentration: t1/2 = [A]₀/(2k). Doubling [A]₀ doubles the half-life if k remains unchanged. For example, the defaults give a half-life of 50 s; the concentration is 0.050 mol/L at that time, exactly half the initial 0.100 mol/L. This result does not mean the reaction remains zero order indefinitely.
When the Zero-Order Model Applies
Zero-order kinetics can occur when the process controlling the observed rate is saturated or otherwise limited by something that does not increase with reactant concentration. For example, an enzyme-catalyzed process can approach a zero-order regime in substrate when the enzyme’s active sites are effectively saturated. A surface-catalyzed reaction may also show zero-order behavior under particular conditions. These are condition-dependent regimes, not proof that a reaction has one order at every concentration.
In experiments, estimate the order by collecting concentration data across time and comparing suitable plots or fitting rate-law models. Check whether the interval includes an initial transient, changing temperature, catalyst deactivation, or other effects that could bend the graph. A straight line over a narrow range is evidence, not a universal mechanism. The observed order is an empirical description of rate dependence under stated conditions; it does not by itself identify the reaction mechanism.
Common Graph and Calculation Mistakes
- Using the wrong axes: For the integrated zero-order law, plot concentration versus time, not logarithm of concentration versus time.
- Dropping the minus sign: The slope is −k. If the fitted slope is −0.001 mol/(L·s), then k is positive 0.001 mol/(L·s).
- Mixing time units: A k value per minute cannot be multiplied by seconds without conversion.
- Extrapolating past depletion: The equation can predict a negative value if used beyond [A]₀/k. Physically, that signals the model’s valid range has ended, not a negative concentration.
- Confusing zero order with zero rate: Zero order means rate does not depend on [A] in the applicable rate law; it does not mean the reaction is stopped.
- Rounding too early: Keep extra digits in fitted slopes and intermediate calculations, then round the reported result to a precision justified by the measurements.
Frequently Asked Questions
What is the slope of a zero-order kinetics graph?
On a plot of reactant concentration against time, the slope is −k. The rate constant k is positive, while the line slopes downward as reactant is consumed.
Which graph is linear for a zero-order reaction?
A plot of [A] versus time is linear if the zero-order model holds. Its y-intercept is [A]₀ and its slope is −k.
How do you calculate k from a graph?
Find the gradient of the concentration-versus-time line and change its sign: k = −slope. Report units consistent with the concentration and time axes.
Does zero-order half-life depend on initial concentration?
Yes. For a zero-order reaction, t1/2 = [A]₀/(2k), so the half-life increases with [A]₀ when k is unchanged.
Can a zero-order concentration become negative?
No. A negative result means the integrated equation was extrapolated beyond the time at which the modeled reactant is depleted, or that the inputs or assumptions need checking.
Related
Formula used
in a0 | Initial reactant concentration [A]₀ | mol/L | 0.100 | 0 in k | Zero-order rate constant k | mol/(L·s) | 0.001 | 0 in t | Elapsed time t | s | 40 | 0 in at | Target concentration [A] | mol/L | 0.050 | 0 out a | Concentration at time t | mol/L | a0 - k * t | 4 out slope | Graph slope | mol/(L·s) | -k | 4 out intercept | Graph y-intercept | mol/L | a0 | 4 out thalf | Zero-order half-life | s | a0 / (2 * k) | 4 out targettime | Time to reach target concentration | s | (a0 - at) / k | 4
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Serial Dilution A Level Biology: How To Do It30
- Serial vs Simple Dilution: Key Differences0.2000 mol/L
- Milton Tablet Dilution: Mixing Guide0.2000 mol/L
- qPCR Serial Dilution Standard Curve: How to Build One100,000 copies/µL
- Serial Dilution Factor: How to Calculate It
- Serial Dilution: Step-by-Step Guide