The zero-order kinetics equation is [A]t = [A]0 − kt, where [A]t is the reactant concentration after time t, [A]0 is its initial concentration, and k is the zero-order rate constant. This calculator uses the initial concentration, rate constant, and elapsed time to calculate the remaining concentration; it also reports the time for the concentration to reach zero when that result is physically meaningful.
Formula
The integrated zero-order rate law is [A]t = [A]0 − kt. In this calculator, [A]0 is the initial concentration in mol/L, k is the zero-order rate constant in mol/(L·s), and t is elapsed time in seconds. The calculated [A]t is concentration remaining in mol/L. The second output, tzero = [A]0/k, is the predicted time in seconds for the concentration to reach zero, assuming the same zero-order rate continues.
The rate law is also written as −d[A]/dt = k: the reactant concentration falls at a constant rate. The minus sign indicates that concentration decreases; k itself is conventionally positive. The calculator accepts nonnegative values. If the elapsed time exceeds the predicted depletion time, the mathematical expression would give a negative concentration, which is not physically meaningful, so the calculator reports that the concentration cannot be computed under the stated model.
Worked Example
Using the defaults in the calculator:
- Initial concentration, [A]0 = 0.100 mol/L
- Rate constant, k = 0.002 mol/(L·s)
- Elapsed time, t = 30 s
Calculate the decrease in concentration: kt = 0.002 mol/(L·s) × 30 s = 0.060 mol/L.
Subtract that decrease from the starting concentration: [A]t = 0.100 mol/L − 0.060 mol/L = 0.0400 mol/L.
The predicted time to zero is tzero = 0.100 mol/L ÷ 0.002 mol/(L·s) = 50.00 s. The calculator rounds the concentration to four decimal places and the time to two.
Assumptions
- The reaction follows a zero-order rate law over the interval being considered.
- The rate constant is constant and has units consistent with the chosen concentration and time units.
- The calculation treats the measured reactant concentration as the quantity governed by the rate law; it does not account for changing conditions or other reactions.
- Zero concentration marks the limit of this simple model; negative concentrations are not interpreted as real results.
What Zero-Order Kinetics Means
A reaction is zero order with respect to a reactant when its rate does not depend on that reactant’s concentration under the conditions studied. If the reactant concentration doubles, the rate remains the same, provided those conditions continue to hold. This differs from first-order kinetics, where rate is proportional to concentration, and second-order kinetics, where rate depends on concentration squared or on a product of concentrations.
“Zero order” describes the observed rate dependence, not necessarily the elementary steps of a reaction. It can arise when another factor controls the rate or becomes limiting. For example, a light-driven reaction can show an approximately constant rate when light intensity is fixed and the reacting system absorbs the available light effectively. Enzyme-catalyzed reactions can approach zero-order behavior with respect to substrate when the enzyme is saturated, although this approximation applies only over an appropriate concentration range. These examples do not mean the reaction is zero order under every condition.
How to Recognize a Zero-Order Reaction
A common test is to measure reactant concentration at several times and plot concentration against time. For a zero-order reaction, the integrated equation predicts a straight line with slope −k and a vertical intercept of [A]0. A strong linear fit over a relevant interval supports the model, but data quality, measurement uncertainty, and competing reaction models also matter.
- A straight-line plot of [A] versus time is consistent with zero-order kinetics.
- The magnitude of the fitted slope gives k, with the appropriate concentration-per-time units.
- A plot of ln[A] versus time is instead linear for a first-order reaction under its integrated rate law.
- A plot of 1/[A] versus time is commonly tested for a second-order reaction in one reactant.
Do not select an order from a single measurement or from the reaction’s name alone. Compare appropriate plots or fit candidate rate laws to data across the range of conditions that matters. A reaction may change apparent order when temperature, light, catalyst availability, or reactant concentration changes.
Units, Half-Life, and Useful Comparisons
For zero-order kinetics, k has units of concentration divided by time, such as mol/(L·s), mol/(L·min), or mg/(L·h). The concentration and time units in the inputs must match the rate constant. For example, if k is in mol/(L·min), enter time in minutes rather than seconds. The product kt then has concentration units, as required for subtraction from [A]0.
The zero-order half-life is not a fixed value independent of starting concentration. Setting [A]t = [A]0/2 in the integrated equation gives t1/2 = [A]0/(2k). Thus, doubling the initial concentration doubles the half-life when k stays constant. This contrasts with the usual first-order half-life, ln(2)/k, which does not depend on initial concentration.
Zero-order concentration decreases linearly only while the zero-order assumption holds. The time-to-zero output is an extrapolation from the specified k; it is not a guarantee that a real reaction proceeds at exactly that rate until the reactant is exhausted.
Common Mistakes and Model Limits
- Mixing units: A rate constant per minute cannot be combined directly with a time entered in seconds. Convert one so the units agree.
- Assuming all reactions are zero order: The order must be supported by measurements or an established model for the particular conditions.
- Using the equation beyond depletion: A negative calculated concentration signals that the model’s time range has been exceeded, not that negative reactant exists.
- Confusing rate with concentration: k is the rate of concentration change in a zero-order model; it is not itself a concentration.
- Overinterpreting rounded values: Extra calculator digits do not imply the measurements or model are equally precise.
The equation assumes a constant rate and a single concentration trajectory described by the model. It does not determine the mechanism, account for changing experimental conditions, or establish whether products form in a particular yield. For laboratory planning or bench work, follow your lab method, the safety data sheet (SDS), and your supervisor.
Frequently Asked Questions
What is the equation for zero-order kinetics?
The integrated equation is [A]t = [A]0 − kt. The differential rate law is −d[A]/dt = k.
What are the units of a zero-order rate constant?
Its units are concentration per time, such as mol/(L·s), because k represents the constant decrease in concentration per unit time.
How do you find k from a concentration-time graph?
Plot concentration against time and fit a straight line. For a zero-order reaction, the slope is −k, so k is the positive magnitude of that slope.
Does zero-order half-life depend on initial concentration?
Yes. The half-life is [A]0/(2k), so it increases in proportion to the starting concentration when k is unchanged.
Can a zero-order reaction have a negative concentration?
No. A negative value from the equation means the calculation was extended beyond the model’s depletion time. Concentration cannot be negative; use the result only within the valid time range.
Related
Formula used
in c0 | Initial concentration | mol/L | 0.100 | 0 in k | Zero-order rate constant | mol/(L·s) | 0.002 | 0 in t | Elapsed time | s | 30 | 0 out ct | Concentration remaining | mol/L | c0 - k * t | 4 out tz | Time to zero concentration | s | c0 / k | 2
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Cell Culture Doubling Time Equation and Calculator24.00 h
- Cell Culture Seeding Density Calculator and Formula4,000.00 cells/cm^2
- Cell Culture Doubling Time Calculator and Formula24.00 h
- CFU From Dilution: Calculate Colony-Forming Units10,000,000 CFU/mL
- Cell Culture Doubling Time Calculator and Formula24.00 h
- Zero Order Release Kinetics Calculator and Explanation5.000 mg/h