Approved Document B is published in two volumes: Volume 1 covers dwellings, while Volume 2 covers buildings other than dwellings. The right volume depends on the building type and the scope of the work; the document is official fire-safety guidance for England, not a calculator or a single-volume handbook.
What Approved Document B covers
Approved Document B (ADB) gives guidance on meeting the fire-safety requirements in Part B of Schedule 1 to the Building Regulations 2010, as they apply in England. Its subject matter includes means of warning and escape, internal and external fire spread, and access and facilities for the fire and rescue service. The Building Regulations contain the legal requirements; ADB describes routes commonly used to demonstrate compliance. Following its guidance is not the only possible approach, but an alternative design needs to demonstrate that the relevant requirements are met.
The phrase “Approved Document B volume” can refer either to which of the two volumes applies or to the document’s physical or digital size. In the regulatory context, “Volume 1” and “Volume 2” mean different building scopes, not two halves that every project must read in full. For a project in England, start by identifying the building’s use and whether it includes a dwelling.
Volume 1: Dwellings
Volume 1 is the guidance for dwellings. It is relevant to a house or flat, and to dwelling-related work such as an extension or a material alteration, subject to the Building Regulations and the provisions applicable to that work. The guidance addresses issues such as escape routes, fire detection and alarm provisions, fire separation, and access for firefighters.
“Dwelling” is the key scope term; it does not simply mean any building where someone might sleep. A hotel, care building, student accommodation, or other residential institution may be classified as a building other than a dwelling for these purposes. The actual building use and regulatory classification matter, so do not select Volume 1 just because occupants sleep in the building.
Volume 2: Buildings other than dwellings
Volume 2 covers buildings other than dwellings. Examples include offices, shops, schools, factories, warehouses, hotels, and many other non-domestic or communal buildings. Its guidance is organised around the differing hazards and design considerations of those uses, including escape, compartmentation, fire spread, and fire-service access.
Some buildings contain both dwellings and shared or non-residential areas. In those cases, it may be necessary to consult both volumes and check how the guidance treats the particular parts of the building and their interfaces. A mixed-use building should not be assigned a volume solely by looking at its main entrance or the largest floor area. The project’s designer or building control body can help establish the relevant scope.
How to choose the right volume
Use this as a starting point, then check the current edition’s scope and any applicable amendments:
- A self-contained house or flat: begin with Volume 1.
- An office, shop, school, warehouse, or similar non-dwelling: begin with Volume 2.
- A hotel, care home, or other residential building that is not a dwelling: generally begin with Volume 2, while checking the building’s exact classification.
- A building with flats plus shared or non-residential spaces: check both volumes where relevant and pay particular attention to the boundary between uses.
- A conversion, extension, or change of use: assess the work and the resulting use, rather than relying only on the building’s previous description.
These are orientation examples, not a substitute for determining how the Building Regulations apply to a specific project. Fire strategy, building layout, height, use, and the work being carried out can all affect which provisions need attention.
Why editions and amendments matter
Approved documents are updated over time. A search result, saved PDF, or printed copy may therefore be an older edition or may not include later amendments. The current government publication page identifies the available volumes and associated revisions. Check the edition and amendments that apply to the project and its date; do not assume that an old copy remains current just because its cover says “Approved Document B.”
Building regulations guidance for England is not automatically the correct guidance for Wales, Scotland, or Northern Ireland, which have their own regulatory arrangements and publications. Projects near a national boundary, or work governed by another jurisdiction, should use the relevant authority’s current documents. The legal framework and applicable transitional provisions can also matter when requirements change.
Common misunderstandings
- “Volume 1 is for all residential buildings.” Not necessarily. The distinction is dwellings versus other buildings; hotels and care buildings are common examples where classification deserves careful checking.
- “Volume 2 replaces Volume 1 for a mixed-use building.” A mixed building may involve guidance from both volumes, depending on the uses and parts concerned.
- “Approved Document B is the law itself.” The Building Regulations set the legal requirements. The approved document provides guidance on ways of meeting them.
- “Using the right volume guarantees compliance.” Selecting the relevant document is only a first step. The design must address the applicable requirements and project details.
Fire-safety design can affect life safety and is sensitive to details such as escape distances, occupancy, construction, and building height. For a real building project, consult the current official guidance and involve an appropriately competent fire-safety professional or building control body where necessary. This is especially important for complex, existing, or mixed-use buildings.
Frequently Asked Questions
Is Approved Document B one volume or two?
It is issued in two volumes: Volume 1 for dwellings and Volume 2 for buildings other than dwellings.
Which volume applies to a house?
Volume 1 is the starting point for a dwelling, including a house. Check the current edition and how it applies to the particular work.
Which volume applies to a hotel?
A hotel is generally treated as a building other than a dwelling, so Volume 2 is usually the starting point. Confirm the building’s classification and relevant guidance for the project.
Do flats use Volume 1?
Volume 1 covers dwellings such as flats, but common areas, shared facilities, and mixed-use elements can bring other guidance into consideration. Check the whole building context.
Where can I get the current Approved Document B?
Use the official GOV.UK Building Regulations guidance and publications pages for England. Verify the edition and any amendments rather than relying on an undated copy.
Does Approved Document B apply throughout the UK?
No. The relevant building regulations and guidance differ among England, Wales, Scotland, and Northern Ireland. Use the documents issued for the jurisdiction where the building is located.
Related
General steps for current mainstream versions; menus can differ by device and version. See the disclaimer or report an error.
More in this section
- Liters to Cubic Meters: Conversion and Examples0.001000 m³
- Normal Cubic Meter to Liters Calculator1,000.00 L
- Qt to Liters Conversion: US and Imperial Quarts0.946353 L
- Meters to Litres: Why Length Alone Is Not Enough1,000.00 L
- Meters to Liters Formula: Convert Length to Volume?1,000.000 L
- Cubic Meters per Hour to Liters per Second0.2778 L/s