The integrated first-order kinetics formula is [A]t = [A]0e−kt, or equivalently ln([A]t/[A]0) = −kt. This calculator uses the initial and remaining concentration and elapsed time to calculate the first-order rate constant, k, in inverse time units.
Formula
The integrated first-order rate law is ln([A]t/[A]0) = −kt. Rearranging to find the rate constant gives k = ln([A]0/[A]t) / t. The calculator also gives the half-life, t1/2 = ln(2)/k.
- [A]0 is the initial concentration of reactant A, in mol/L.
- [A]t is its concentration after elapsed time t, in mol/L.
- t is elapsed time, in seconds for this calculator.
- k is the first-order rate constant, in s−1 when t is in seconds.
- t1/2 is the time for the concentration to fall to half its initial value, in seconds.
The logarithm is the natural logarithm, ln. Concentrations may use any consistent unit because their ratio is dimensionless, but the two concentration inputs must use the same unit. The value of k has the reciprocal of the time unit entered; this calculator labels it s−1, so enter time in seconds.
Worked Example
Using the calculator’s default values, the initial concentration is 1 mol/L, the concentration after 10 s is 0.5 mol/L, and the elapsed time is 10 s.
Calculate k:
k = ln(1 / 0.5) / 10 s
k = ln(2) / 10 s
k = 0.693147 / 10 s
k = 0.0693 s−1
Calculate the half-life:
t1/2 = ln(2) / 0.0693147 s−1
t1/2 = 10.000 s
The calculated k is rounded to four decimal places, as shown in the output. The half-life uses the unrounded k in the expression and is also displayed to four decimal places.
Assumptions
- The reaction follows a single first-order rate law over the time interval being analyzed.
- The concentration measurements refer to the same reactant and use the same concentration unit.
- The initial concentration is greater than zero, the measured concentration is greater than zero, and elapsed time is positive. A logarithm cannot be calculated for zero concentration, and a rate constant cannot be inferred from zero elapsed time.
- The rate constant is treated as constant during the measurement interval; changes in temperature or reaction conditions can change k.
How First-Order Kinetics Works
For a first-order reaction in A, the instantaneous disappearance rate is proportional to the amount of A remaining: −d[A]/dt = k[A]. The minus sign indicates that the reactant concentration decreases. Integrating this differential rate law from the initial concentration to the concentration at time t produces the logarithmic equation above.
The exponential form makes the time course clear: [A]t = [A]0e−kt. The reactant does not decrease by the same absolute amount in every equal time interval. Instead, it decreases by the same fraction in equal intervals when k is constant. After one half-life, half remains; after two half-lives, one quarter remains; after three, one eighth remains.
First-order describes how the rate depends on concentration; it does not say that the reaction has only one step or that the concentration-versus-time curve is a straight line. A complex mechanism can sometimes show apparent first-order behavior under particular conditions.
Using the Calculator and Reading k
Enter the starting concentration, a later concentration, and the time between those measurements. The output k is nonnegative when the reactant concentration declines. A larger k means faster fractional disappearance under the stated conditions. The half-life output is a useful way to interpret k in units of elapsed time.
- For measurements in minutes, convert the elapsed time to seconds before using this calculator; alternatively, calculate k in min−1 by using minutes in the equation and interpret the units accordingly.
- For a concentration ratio, use matching units, such as mol/L for both values or mmol/L for both. Do not divide values expressed in different units without converting them first.
- Use concentrations that are positive and meaningfully above the measurement’s detection limit. A reported zero usually means “below the method’s limit,” not necessarily a true concentration of zero.
If the measured concentration is greater than the initial value, this calculation returns a negative k, which is inconsistent with the usual model of a reactant being consumed. That may indicate a unit or data-entry error, concentration increase, or that the selected species is being formed rather than consumed. Consider whether the stated reaction direction and model are appropriate.
Checking First-Order Behavior with Data
With multiple concentration measurements, calculate ln([A]) for each and plot it against time. First-order behavior predicts a straight line, whose slope is −k and whose vertical intercept is ln([A]0). A single pair of measurements can produce a value of k, but it cannot establish that the reaction is genuinely first order; several data points help reveal curvature, outliers, or changes in conditions.
Another check is whether the half-life remains approximately constant across successive concentration halvings. This is characteristic of a first-order model, unlike a zero-order reaction, where concentration falls by equal absolute amounts per unit time, or a second-order reaction, whose integrated law has a different concentration dependence.
When fitting experimental data, measurement uncertainty matters. Taking a logarithm magnifies the influence of small or imprecise concentrations, especially near zero. Use the actual unrounded measurements for calculations where possible, and report appropriate significant figures rather than implying that displayed calculator digits represent measurement precision.
Common Misconceptions and Limits
The differential law and integrated law are related but serve different purposes. The differential form, −d[A]/dt = k[A], describes the instantaneous rate; the integrated form relates concentration to elapsed time. In the integrated equation the exponent must be dimensionless, so k and t must have reciprocal and matching time units.
Do not confuse first-order kinetics with a “first-order” reaction mechanism in every context. The observed reaction order is determined by the rate law, often from measurements, and may not match a balanced equation’s coefficients. For an elementary reaction, stoichiometry can inform the rate law; for an overall multistep reaction, it generally cannot be inferred from the overall equation alone.
The simple equation may not fit if temperature changes, the reaction reverses appreciably, a product affects the rate, the mechanism changes, or measurements combine multiple processes. It also assumes the concentration used represents the reacting system adequately. In such cases, use a model that reflects the chemistry and conditions rather than forcing a first-order fit. For laboratory work, follow your lab method, the safety data sheet (SDS), and your supervisor.
Frequently Asked Questions
What is the formula for a first-order reaction?
The integrated formula is [A]t = [A]0e−kt, or ln([A]t/[A]0) = −kt. The rate law is −d[A]/dt = k[A].
What are the units of the first-order rate constant?
k has units of inverse time, such as s−1, min−1, or h−1. The chosen unit depends on the time unit used in the calculation.
How do you calculate the first-order rate constant?
Use k = ln([A]0/[A]t)/t. Both concentrations must use the same unit, and t must be positive.
How do you calculate the half-life of a first-order reaction?
Use t1/2 = ln(2)/k, approximately 0.693/k. Under constant first-order conditions, the half-life does not depend on the initial concentration.
Does first-order mean the concentration decreases linearly?
No. Concentration decays exponentially with time. A plot of ln(concentration) against time is linear when the first-order model applies.
Can one measurement pair prove a reaction is first order?
No. A pair can be used to calculate an apparent k, but multiple measurements across time are needed to assess whether the logarithmic concentration plot is approximately linear.
Related
Formula used
in a0 | Initial concentration | mol/L | 1 | 0 in at | Concentration at time t | mol/L | 0.5 | 0 in t | Elapsed time | s | 10 | 0 out k | First-order rate constant k | s^-1 | ln(a0 / at) / t | 4 out th | Half-life | s | ln(2) / k | 4
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Serial Dilution A Level Biology: How To Do It30
- Serial vs Simple Dilution: Key Differences0.2000 mol/L
- Milton Tablet Dilution: Mixing Guide0.2000 mol/L
- qPCR Serial Dilution Standard Curve: How to Build One100,000 copies/µL
- Serial Dilution Factor: How to Calculate It
- Serial Dilution: Step-by-Step Guide