DNA Purity Calculator: Check A260/A280 and A260/A230

Calculator No. 01-3568 · Updated · Formula and assumptions shown below

A260/A280 purity ratio 1.82 ratio
A260/A230 purity ratio
2.00 ratio
= Absorbance at 260 nm ÷ Absorbance at 230 nm
Absorbance at 260 nm
0.5 AU
Set in the form below
Absorbance at 280 nm
0.275 AU
Set in the form below
You enter
Absorbance at 260 nm (AU), Absorbance at 280 nm (AU), Absorbance at 230 nm (AU)
You get
A260/A280 purity ratio (ratio), A260/A230 purity ratio (ratio)
Rounding
2 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

This calculator estimates DNA purity from absorbance readings at 260, 280, and 230 nm. Enter the readings from a blank-corrected UV measurement to get the A260/A280 and A260/A230 ratios, then compare them with typical reference ranges. You will need a UV spectrophotometer or microvolume instrument and a blank made with the same buffer as the DNA sample.

Formula

The calculator divides the blank-corrected absorbance at 260 nm by the absorbance at each comparison wavelength:

  • A260/A280 = A260 ÷ A280
  • A260/A230 = A260 ÷ A230

A260, A280, and A230 are absorbance readings in absorbance units (AU), measured at wavelengths of 260, 280, and 230 nanometres. Absorbance is dimensionless, so the ratios are also dimensionless. The calculator assumes all three readings come from the same sample, path length, instrument settings, and blank correction. Enter nonnegative readings; a zero denominator cannot produce a ratio.

Worked Example

Using the calculator’s default readings:

  1. A260/A280 = 0.500 AU ÷ 0.275 AU = 1.81818…, which rounds to 1.82.
  2. A260/A230 = 0.500 AU ÷ 0.250 AU = 2.00000, which is 2.00.

The ratios are screening indicators, not a direct measurement of every contaminant or proof that the DNA will work in a particular experiment.

Assumptions

  • The entered absorbances are blank-corrected and measured from the same sample under comparable conditions.
  • The instrument is operating within its validated absorbance range, and the sample is sufficiently mixed and free of bubbles or visible particles.
  • Reference values are approximate guides. DNA type, pH, buffer composition, concentration, and instrument design can affect readings.

What You’ll Need

  • A UV-visible spectrophotometer or microvolume instrument capable of reading at 230, 260, and 280 nm.
  • Your DNA sample and the exact buffer or solvent used to dissolve it, for blanking.
  • Clean measurement surfaces or suitable clean cuvettes, lint-free wipes, and gloves as required by your lab rules.
  • The instrument’s instructions and your lab’s DNA measurement protocol.

For bench work, follow your lab method, the safety data sheet (SDS), and your supervisor. Keep samples identified and avoid cross-contamination; absorbance results are only as reliable as the handling and blank.

Step-by-Step

  1. Check the measurement method. Confirm that the instrument can read all three wavelengths and that the sample is within its recommended concentration and absorbance range. If the DNA is too concentrated, use a validated dilution with a compatible buffer and record the dilution factor. Ratios themselves are unchanged by an ideal dilution, but readings outside the instrument’s linear range are unreliable.
  2. Prepare the blank. Use the same buffer or solvent as the DNA sample, not water unless the DNA is actually in water. Blank the instrument according to its operating instructions. A mismatched blank can create misleadingly high or low absorbance, especially at 230 nm.
  3. Measure the sample consistently. Mix gently, avoiding bubbles. Load the sample as directed for the instrument, ensure the measurement surface or cuvette is clean, and collect readings at 230, 260, and 280 nm. For a cuvette instrument, use the same orientation and path length. Wipe away residues between samples using the approved cleaning procedure.
  4. Review the raw readings. Use blank-corrected values from a single measurement run. Check for warning messages, saturation, poor repeatability, or a negative reading after blanking. Do not substitute a reading from another sample or an incompatible measurement mode.
  5. Enter the absorbances. Type the A260, A280, and A230 values into the calculator in absorbance units. Do not enter DNA concentration, wavelength, or a percentage. If your instrument reports several decimal places, retain them during calculation rather than rounding the inputs first.
  6. Calculate and compare both ratios. Read the A260/A280 and A260/A230 results. As broad conventions, relatively pure DNA often has an A260/A280 near 1.8 and an A260/A230 around 2.0–2.2. These are not universal pass/fail cutoffs; use the acceptance criteria for your downstream application and measurement method.
  7. Decide whether to proceed or investigate. If a ratio is unexpected, repeat the measurement after checking the blank, sample loading, and instrument cleanliness. If the result remains outside the range your method requires, consider a suitable cleanup or an independent DNA quality check rather than treating the ratio as a diagnosis.

Common Mistakes

  • Using the wrong blank: A blank should match the sample’s buffer. Differences in salts, pH, or other dissolved substances can alter the baseline.
  • Mixing up wavelength values: Enter the absorbance at 260 nm as A260, not the wavelength number 260 itself. Each field takes an absorbance reading.
  • Comparing incompatible measurements: Do not compare readings taken with different path lengths, buffers, or instrument modes as if they were directly equivalent.
  • Trusting ratios from weak signals: When absorbance is close to the instrument’s detection limit, small baseline errors can strongly affect a ratio. A plausible-looking ratio does not guarantee a reliable concentration measurement.
  • Assuming a ratio proves DNA integrity: These ratios do not show whether DNA is fragmented, whether it contains RNA, or whether it will perform well in a specific assay.
  • Rounding too early: Keep the original absorbance readings for calculation, and round only the reported ratios to an appropriate number of decimal places.

Tips

  • Record the buffer, sample dilution, instrument mode, and raw absorbances alongside the ratios so measurements can be reproduced.
  • Measure replicates when your method calls for them. Large variation between repeats suggests a loading, mixing, blanking, or instrument problem.
  • Use a fluorometric DNA assay when you need a more selective DNA concentration estimate; UV absorbance can also respond to RNA and other absorbing substances.
  • Interpret both ratios alongside concentration, sample history, and the requirements of the next procedure. A ratio in a typical range is useful evidence, not a guarantee.

Troubleshooting

A ratio is much higher or lower than expected: Reblank with the sample’s exact buffer, clean the measurement surface or cuvette, and repeat with a well-mixed sample. Confirm that readings were entered in the correct fields and that none came from a different run.

A230 is near zero or negative: The ratio may be undefined or unstable. Check blank matching and instrument baseline, then repeat. Do not interpret a huge ratio caused by dividing by a value near zero as evidence of exceptional purity.

Readings vary between repeats: Look for bubbles, fingerprints, residue, insufficient sample volume, or inconsistent cuvette positioning. Follow the instrument’s minimum-volume and cleaning instructions.

The instrument reports an out-of-range reading: Follow its guidance and repeat using a validated dilution or measurement mode. Apply any dilution factor when reporting concentration, but do not multiply the purity ratios by that factor.

Ratios look acceptable but an experiment fails: Check DNA integrity, concentration by an appropriate method, and possible inhibitors. UV purity ratios alone cannot identify all causes of poor downstream performance.

Frequently Asked Questions

What is a good A260/A280 ratio for DNA?
About 1.8 is a commonly used reference for relatively pure DNA. Treat it as a guide, since buffer, pH, concentration, and instrument conditions affect the value.

What is a good A260/A230 ratio?
Values around 2.0–2.2 are often cited for clean DNA. A lower result can indicate carryover that absorbs near 230 nm, but it does not identify the substance by itself.

Can I check purity using only A260/A280?
You can calculate that ratio, but it gives an incomplete view. A260/A230 provides a second screening indicator, and neither replaces other quality checks when they are required.

Does a good ratio mean my DNA is intact?
No. Absorbance ratios do not show DNA fragment size or degradation. Use an appropriate integrity check if fragment length matters for your work.

Should I include a dilution factor in the ratios?
No. If all readings are measured from the same dilution, the common dilution factor cancels in each ratio. It is relevant when calculating concentration from absorbance, not these ratios.

Why can a ratio be unreliable at low DNA concentration?
When absorbance is weak, baseline noise and small blanking errors make up a larger share of the signal. Repeat the measurement or use a more suitable DNA quantification method.

Related

Formula used
in a260 | Absorbance at 260 nm | AU | 0.500 | 0
in a280 | Absorbance at 280 nm | AU | 0.275 | 0
in a230 | Absorbance at 230 nm | AU | 0.250 | 0
out r28 | A260/A280 purity ratio | ratio | a260 / a280 | 2
out r23 | A260/A230 purity ratio | ratio | a260 / a230 | 2

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section