molecalculator

Moles & Molar Mass

Ideal Gas Constant in CGS: Value, Units, and Conversion

Calculator No. 01-5693 · Updated · Formula and assumptions shown below

Ideal gas constant in cgs 83,144,626.182 erg/(mol·K)
Ideal gas constant
1.9872 cal/(mol·K)
= Gas constant ÷ 4.184
Gas constant
8.3144626182 J/(mol·K)
Set in the form below
You enter
Gas constant (J/(mol·K))
You get
Ideal gas constant in cgs (erg/(mol·K)), Ideal gas constant (cal/(mol·K))
Rounding
3 dp · 4 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

The ideal gas constant in cgs units is 8.314462618 × 107 erg·mol−1·K−1. This calculator converts the universal gas constant from joules to ergs; enter a value in J/(mol·K) and it returns the equivalent cgs value.

Formula

The conversion is Rcgs = RSI × 107. Here, RSI is the gas constant in joules per mole per kelvin (J/(mol·K)); Rcgs is the same constant in ergs per mole per kelvin (erg/(mol·K)). The factor 107 comes from the exact energy conversion 1 J = 107 erg. The optional calorie output uses 1 cal = 4.184 J, so R in cal/(mol·K) is RSI / 4.184.

Worked Example

Using the default input, RSI = 8.31446261815324 J/(mol·K):

  • Convert joules to ergs: 8.31446261815324 × 10,000,000 = 83,144,626.1815324 erg/(mol·K).
  • Rounded to the calculator’s three decimal places, the cgs result is 83,144,626.182 erg/(mol·K), or approximately 8.314 × 107 erg/(mol·K).
  • For comparison, 8.31446261815324 / 4.184 = 1.98720425864083 cal/(mol·K), which rounds to 1.9872 cal/(mol·K).

Assumptions

  • The input is the universal molar gas constant, not a gas-specific property.
  • The conversion treats 1 J = 107 erg and 1 cal = 4.184 J as exact unit definitions.
  • The result is expressed per mole and per kelvin; the calculator does not convert amount or temperature units.

Why the cgs Value Is Larger

The cgs system uses centimetres, grams, and seconds as its basic mechanical units. Its energy unit is the erg, defined as one dyne-centimetre. The SI energy unit is the joule. One joule equals ten million ergs, so the numerical value of R in erg/(mol·K) is ten million times its numerical value in J/(mol·K). The physical constant has not changed; only the unit used to report energy has changed.

The symbol R denotes the same universal constant in equations such as the ideal gas law, PV = nRT. In that expression, pressure P multiplied by volume V must have energy units, matching nRT. If you use pressure in dyn/cm² and volume in cm³, their product has units of erg, because (dyn/cm²)(cm³) = dyn·cm = erg. Then R should be entered in erg/(mol·K), and the temperature must be absolute temperature in kelvins.

For one mole at one kelvin, the energy scale nRT is about 8.314 × 107 erg. This is a unit-based interpretation of the constant, not a claim that every gas sample contains that energy in a simple, directly measurable form; the thermodynamic meaning depends on the process and the quantities being considered.

Using R Consistently in cgs Gas Laws

The conversion is useful when a derivation or data set uses cgs units throughout. For example, a pressure of 1 atm is about 1.01325 × 106 dyn/cm², and a volume of 1 L is 1000 cm³. Their product is about 1.01325 × 109 erg. With R in cgs units, PV = nRT can then be evaluated consistently using pressure in dyn/cm², volume in cm³, amount in mol, and temperature in K.

For ordinary calculations, it is often simpler to use the SI form of the constant, R = 8.31446261815324 J/(mol·K), with pressure in pascals and volume in cubic metres. The cgs form is not more or less physically correct: it is convenient only when the rest of the calculation uses compatible cgs units. Mixing units without conversion is a common source of errors.

  • If pressure is in dyn/cm² and volume in cm³, use R in erg/(mol·K).
  • If pressure is in pascals and volume in m³, use R in J/(mol·K).
  • If pressure is in atmospheres and volume in litres, use the compatible value R ≈ 0.0820574 L·atm/(mol·K).
  • If pressure is in bars and volume in litres, use R ≈ 0.0831446 L·bar/(mol·K).

Always convert Celsius temperatures to kelvins before using the ideal gas law: T(K) = t(°C) + 273.15. The ideal gas equation uses absolute temperature, and inserting a Celsius number directly gives an invalid result.

Related Values and Common Mix-Ups

Several commonly quoted numerical values for R are equivalent, but their units differ. The SI value is 8.31446261815324 J/(mol·K); the cgs value is 8.31446261815324 × 107 erg/(mol·K); and a traditional calorie-based value is about 1.9872 cal/(mol·K). A number for R cannot be interpreted correctly without its units.

A frequent confusion is between the molar gas constant R and the Boltzmann constant kB. R applies per mole, while kB applies per particle. They are related by R = NAkB, where NA is the Avogadro constant. Do not substitute one for the other unless the equation and amount units are changed accordingly.

Another potential mix-up is treating “cgs” as if it identifies one unique form of every unit. In practical work, pressure might be expressed in baryes (dyn/cm²), while other cgs conventions or legacy tables use different pressure units. Check the full units attached to every quantity, especially when converting a tabulated pressure or energy.

When the Ideal-Gas Model Applies

The value of R is universal, but the ideal gas law is an approximation. It is generally most useful when a gas is sufficiently dilute that molecular volume and intermolecular attractions have small effects. At high pressures or near condensation, real gases can deviate substantially; an equation of state designed for non-ideal behavior may be needed. Changing from SI to cgs does not correct or cause those physical deviations.

The calculator converts units only. It does not determine whether a gas is ideal under given conditions, choose a pressure convention, or validate the values entered into a separate gas-law calculation. Its input should be the molar gas constant in J/(mol·K); entering a value already expressed in cgs units would multiply it by 107 again and produce an incorrect result.

Frequently Asked Questions

What is the ideal gas constant in cgs units?
R = 8.314462618 × 107 erg/(mol·K), equivalently 83,144,626.18 erg/(mol·K) to two decimal places.

How do you convert R from joules to ergs?
Multiply its value in J/(mol·K) by 107, because 1 J = 107 erg. Keep the mole and kelvin units unchanged.

Is the cgs gas constant different from the SI gas constant?
No. It is the same physical constant expressed with a different energy unit. The numerical value changes because a joule contains 107 ergs.

Can I use R in erg/(mol·K) with pressure in atmospheres?
Not directly with volume in litres. Convert pressure and volume to units whose product is ergs, or use an R value compatible with L·atm, about 0.0820574 L·atm/(mol·K).

What is R in calories per mole per kelvin?
Using the thermochemical calorie definition, 1 cal = 4.184 J, R is approximately 1.9872 cal/(mol·K).

Does this value depend on the gas?
No. R is universal. The ideal-gas approximation’s accuracy depends on the gas and its conditions, but the constant itself does not change between gases.

Related

Formula used
in r | Gas constant | J/(mol·K) | 8.31446261815324 | 0
out rcgs | Ideal gas constant in cgs | erg/(mol·K) | r * 10000000 | 3
out rcal | Ideal gas constant | cal/(mol·K) | r / 4.184 | 4

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →