molecalculator

Moles & Molar Mass

SFC to Liters: Convert Standard Cubic Feet

Calculator No. 01-7293 · Updated · Formula and assumptions shown below

Volume in Liters 2,831.68 L
Volume in SCF
100 SCF
Set in the form below
You enter
Volume in SCF (SCF)
You get
Volume in Liters (L)
Rounding
2 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

This calculator converts a volume of gas measured in standard cubic feet (SCF) to liters (L). You enter the volume in SCF, and you get the equivalent volume in liters at the same standard conditions (typically 60°F and 14.696 psia). The conversion is a straightforward unit change based on the fixed relationship between cubic feet and liters: 1 cubic foot equals exactly 28.316846592 liters.

Formula

The conversion uses the exact definition of the liter and the cubic foot:

Liters = SCF × 28.316846592

  • SCF = volume of gas in standard cubic feet (dimensionless number of cubic feet)
  • Liters = equivalent volume in liters (L)
  • 28.316846592 = exact number of liters in one cubic foot (1 ft³ = 28.316846592 L)

This factor is exact because both the international foot (0.3048 m) and the liter (0.001 m³) are defined in SI units. One cubic foot is (0.3048 m)³ = 0.028316846592 m³, and one liter is 0.001 m³, so 0.028316846592 / 0.001 = 28.316846592 L per ft³.

Worked Example

Using the default value of 100 SCF from the calculator:

  1. Start with the volume: 100 SCF
  2. Multiply by the conversion factor: 100 × 28.316846592
  3. Result: 2831.6846592 L
  4. Rounded to two decimals (as the calculator shows): 2831.68 L

So 100 standard cubic feet of any gas equals 2831.68 liters at the same temperature and pressure.

Assumptions

  • The conversion is purely volumetric; it does not depend on the type of gas.
  • Both SCF and liters refer to the same temperature and pressure conditions (the calculator does not change conditions, only units).
  • The international foot (exactly 0.3048 m) is used, which is the standard in gas measurement.
  • Standard conditions (60°F, 14.696 psia for SCF) are assumed to be identical for both sides of the conversion; if your SCF uses a different standard (e.g., 15°C, 1 atm), the conversion factor remains the same because you are only changing units, not conditions.

What “Standard” Means in SCF

The term “standard cubic foot” is a measurement of gas volume at a defined reference condition. The most common standard in the United States is 60°F (15.56°C) and 14.696 psia (1 atmosphere). However, other standards exist: the International Standard Organization (ISO) uses 15°C (59°F) and 1.01325 bar, and some European standards use 0°C and 1 atm (often called “normal” cubic meters, Nm³). The conversion from SCF to liters is unaffected by which standard you use, because you are only converting the unit of volume, not adjusting for temperature or pressure. If you need to convert gas at non-standard conditions to standard conditions, you would need the ideal gas law, not this unit conversion.

When to Use This Conversion

This conversion is useful in gas flow calculations, compressed air systems, natural gas metering, and laboratory gas handling. For example, if a gas cylinder is rated at 250 SCF, you can quickly find it holds 250 × 28.316846592 = 7080.21 L of gas at standard conditions. This is helpful when comparing gas volumes across different unit systems, when filling gas bags or sampling containers with a known volume in liters, or when reading a flow meter that outputs SCF but your experiment requires liters. The conversion is also used in environmental reporting and emissions calculations where gas volumes must be expressed in metric units.

Common Mistakes and Misconceptions

  • Confusing SCF with ACF (actual cubic feet): SCF is corrected to standard conditions, while ACF is the volume at the actual pressure and temperature. This calculator converts SCF to liters at the same standard conditions; it does not correct ACF to standard conditions.
  • Using the wrong conversion factor: Some sources round 1 ft³ to 28.32 L. That is fine for rough estimates, but for precise work use the exact 28.316846592.
  • Mixing up liters and cubic meters: 1 m³ = 1000 L, and 1 ft³ = 0.028316846592 m³, so 1 ft³ = 28.316846592 L. Do not confuse the two.
  • Forgetting that SCF is not a mass: The same SCF of different gases contains different numbers of molecules (and different masses). This conversion only changes volume units; it does not tell you how many moles or kilograms of gas you have.

Related Conversions and Context

If you need to convert liters to SCF, divide by 28.316846592. For larger volumes, you might convert SCF to cubic meters (divide by 35.314666721489) or to normal cubic meters (Nm³), which requires a temperature and pressure correction. For gas flow rates, SCF per minute (SCFM) is common; to get liters per minute, multiply SCFM by 28.316846592. This conversion is also the basis for comparing gas cylinder capacities across manufacturers that use different unit systems. Remember that the volume of a real gas at standard conditions is very close to ideal, but for extremely high pressures or low temperatures, real-gas corrections (compressibility factor) may be needed; this unit conversion does not account for those effects.

Frequently Asked Questions

Is 1 SCF equal to 28.32 liters exactly?

Yes, 1 SCF equals exactly 28.316846592 liters. The number 28.32 is a rounded approximation. The exact value comes from the definition of the international foot (0.3048 m) and the liter (0.001 m³). For most practical purposes, 28.32 L is close enough, but for precise calculations use the full factor.

Does the type of gas matter for this conversion?

No. The conversion from cubic feet to liters is purely a unit conversion of volume. Whether you have nitrogen, oxygen, methane, or air, 1 SCF of any gas occupies the same volume in liters at the same standard conditions. However, the mass or number of moles in that volume will differ by gas.

What is the difference between SCF and SL (standard liters)?

SCF and SL (or standard liters) both refer to gas volumes at standard conditions. The only difference is the unit: SCF uses cubic feet, and SL uses liters. One SCF equals 28.316846592 SL. Both assume the same reference temperature and pressure, typically 60°F and 14.696 psia for US standards.

How do I convert SCFM to liters per minute?

Multiply the SCFM value by 28.316846592. For example, 10 SCFM × 28.316846592 = 283.17 L/min. This gives the volumetric flow rate at standard conditions in liters per minute.

Why do some standards use 15°C and others use 60°F?

Different industries and countries adopted different reference conditions historically. The US natural gas industry commonly uses 60°F (15.56°C) and 14.696 psia. ISO and many international bodies use 15°C (59°F) and 1.01325 bar. Both are “standard” but not identical; the difference in volume is small (about 0.9%) but can matter for precise accounting. This conversion factor does not change between these standards because it only converts units, not conditions.

Can I use this calculator for natural gas billing?

Yes, for converting the volume unit. However, natural gas billing often uses energy content (therms or kWh) rather than just volume, and the heating value of the gas varies by composition. This calculator only converts SCF to liters; it does not calculate energy. For billing, you would need the gas’s heating value and the applicable standard conditions.

Related

Formula used
in scf | Volume in SCF | SCF | 100 | 0
out l | Volume in Liters | L | scf * 28.316846592 | 2

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section