molecalculator

Moles & Molar Mass

Thermal Conductivity to R Value Calculator

Calculator No. 01-10371 · Updated · Formula and assumptions shown below

R-value 2.500 m²·K/W
R-value (SI)
2.500 m²·K/W
= R-value
R-value (imperial)
14.196 h·ft²·°F/Btu
= R-value × 5.678263
Thermal conductivity (k)
0.04 W/(m·K)
Set in the form below
You enter
Thermal conductivity (k) (W/(m·K)), Thickness (mm)
You get
R-value (m²·K/W), R-value (SI) (m²·K/W), R-value (imperial) (h·ft²·°F/Btu)
Rounding
3 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

This calculator converts thermal conductivity (k, in W/m·K) into an R-value (in m²·K/W) for a given material thickness. You enter the material’s thermal conductivity and its thickness; the calculator returns the R-value, which measures resistance to heat flow. The formula is R = thickness / k, and this page explains how to use it correctly, including unit conversions and common pitfalls.

Formula

The basic relationship is:

R = L / k

  • R = thermal resistance (R-value) in m²·K/W
  • L = thickness of the material in meters (m)
  • k = thermal conductivity in W/(m·K)

In the calculator, thickness is entered in millimeters (mm), so the formula becomes R = (t / 1000) / k. The imperial R-value (often used in the US, in h·ft²·°F/Btu) is obtained by multiplying the SI value by 5.678263 (since 1 m²·K/W = 5.678263 h·ft²·°F/Btu).

Worked Example

Suppose you have a fiberglass insulation board with a thermal conductivity of 0.04 W/(m·K) and a thickness of 100 mm (0.1 m).

  1. Convert thickness to meters: 100 mm = 100 / 1000 = 0.1 m
  2. Apply the formula: R = 0.1 / 0.04 = 2.5 m²·K/W
  3. Convert to imperial R-value: 2.5 × 5.678263 = 14.2 h·ft²·°F/Btu

The calculator returns R = 2.5 m²·K/W (and 14.2 imperial). This matches the default values.

Assumptions

  • The material is homogeneous and isotropic (same conductivity in all directions).
  • Steady-state heat flow (no time-dependent effects).
  • Thermal conductivity is constant over the temperature range of interest.
  • No air gaps, moisture, or compression that would alter the effective conductivity.

Understanding Thermal Conductivity and R-Value

Thermal conductivity (k) measures how well a material conducts heat. Low k means good insulation (e.g., air ~0.025, fiberglass ~0.04, wood ~0.12, steel ~50 W/(m·K)). R-value measures resistance to heat flow; higher R means better insulation. The two are inversely related for a given thickness: thicker material or lower k gives higher R.

In building physics, R-values are used to compare insulation products. For example, a 150 mm layer of mineral wool (k=0.035) gives R = 0.15/0.035 = 4.29 m²·K/W, while the same thickness of extruded polystyrene (k=0.030) gives R = 5.0. The calculator helps you make such comparisons.

How to Use the Calculator

  1. Find the thermal conductivity (k) of your material. Common values: polyurethane foam ~0.025, glass wool ~0.04, brick ~0.7, concrete ~1.5 W/(m·K).
  2. Measure or specify the thickness in millimeters (e.g., 50, 100, 200).
  3. Enter both values; the calculator gives R in SI and imperial units.

If you have a target R-value and want to find required thickness, rearrange: L = R × k. For example, to achieve R=3.5 m²·K/W with k=0.04, you need L = 3.5 × 0.04 = 0.14 m = 140 mm.

Common Mistakes and Misconceptions

  • Mixing units: k is often given in W/(m·K), but sometimes in W/(cm·K) or BTU/(hr·ft·°F). Always convert to W/(m·K) first. 1 W/(cm·K) = 100 W/(m·K); 1 BTU/(hr·ft·°F) = 1.730735 W/(m·K).
  • Forgetting thickness conversion: If thickness is in cm, divide by 100; if in inches, multiply by 0.0254 to get meters.
  • Confusing R-value with U-value: U-value (thermal transmittance) is the reciprocal of R (U = 1/R). Lower U is better insulation. Some people mistakenly think higher U is better.
  • Ignoring the effect of moisture: Wet insulation has higher k (conducts more heat), so the R-value drops. This calculator assumes dry material.

Choosing the Right Insulation Thickness

Building codes often specify minimum R-values for walls, roofs, and floors based on climate zones. For example, in cold climates, a roof might require R=6.0 m²·K/W (about R-34 imperial). Using the calculator, you can determine how thick a given material must be to meet the code. For a material with k=0.035, required thickness = 6.0 × 0.035 = 0.21 m = 210 mm. This helps in planning material quantities and costs.

Limitations of the R-Value Model

The R-value model assumes steady-state, one-dimensional heat flow. It does not account for:

  • Thermal bridging through studs or framing (which reduces effective R).
  • Air infiltration and convection within the insulation.
  • Radiant heat transfer (especially in low-density materials).
  • Temperature-dependent conductivity (some materials change k with temperature).

For real-world building design, use the calculator for comparative estimates, but consult a professional for final decisions.

Frequently Asked Questions

What is the difference between R-value and thermal conductivity?

Thermal conductivity (k) is a material property—how well a material conducts heat regardless of thickness. R-value is a property of a specific piece of material—it depends on both k and thickness. A thick piece of a moderately insulating material can have a higher R-value than a thin piece of a better insulator.

How do I convert imperial R-value to SI?

Multiply the imperial R-value (h·ft²·°F/Btu) by 0.176110 to get SI (m²·K/W). Conversely, multiply SI by 5.678263 to get imperial. For example, R-19 imperial is 19 × 0.176110 = 3.35 m²·K/W.

Why does my insulation say R-30 but the calculator gives a different number?

Insulation labels usually list the imperial R-value (h·ft²·°F/Btu) for a specific thickness. The calculator gives SI by default. Also, the label’s R-value is often measured at a standard temperature and may assume no compression. If you enter the labeled thickness and the material’s nominal k, you should get close, but variations in manufacturing can cause small differences.

Can I use this calculator for multiple layers?

Yes, but you need to calculate each layer’s R-value separately and then add them: R_total = R1 + R2 + R3… For example, a wall with 12 mm drywall (k=0.17) and 100 mm fiberglass (k=0.04) gives R_drywall = 0.012/0.17 = 0.071 and R_fiberglass = 0.1/0.04 = 2.5, total = 2.571 m²·K/W. The calculator handles one layer at a time.

What is a good R-value for a house?

It depends on your climate. In the US, recommended attic R-values range from R-30 (warm climates) to R-60 (cold climates) in imperial units. That corresponds to 5.3 to 10.6 m²·K/W. For walls, R-13 to R-21 imperial (2.3 to 3.7 m²·K/W) are typical. Check local building codes for minimums.

Does the calculator work for liquids or gases?

Yes, the formula R = L/k applies to any homogeneous material, including liquids and gases. However, for gases, convection often dominates over conduction, so the effective R-value may be lower than calculated. For liquids, you can use it but be aware that movement (convection) will reduce resistance.

Related

Formula used
in k | Thermal conductivity (k) | W/(m·K) | 0.04 | 0.001 | 500
in t | Thickness | mm | 100 | 0.1 | 5000
out r | R-value | m²·K/W | t / 1000 / k | 3
out r_si | R-value (SI) | m²·K/W | r | 3
out r_imperial | R-value (imperial) | h·ft²·°F/Btu | r * 5.678263 | 3

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →