molecalculator

Moles & Molar Mass

Tritium Half Life & Decay Constant

Calculator No. 01-7126 · Updated · Formula and assumptions shown below

The calculator on this page is switched off while it is checked. The formula is below, and the worked example shows how to do the sum by hand.

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

Tritium (³H or T) is a radioactive isotope of hydrogen with a half-life of 12.32 years and a decay constant of approximately 1.78 × 10⁻⁹ s⁻¹. The decay constant (λ) is the probability per unit time that a given nucleus will decay, and for tritium it equals ln(2) divided by the half-life.

Formula

The relationship between half-life (t₁/₂) and decay constant (λ) is:

λ = ln(2) / t₁/₂

where:

  • λ = decay constant (units of inverse time, e.g., s⁻¹, yr⁻¹, d⁻¹)
  • t₁/₂ = half-life (same time unit as the denominator)
  • ln(2) ≈ 0.693147

The decay constant is the probability per unit time that a single nucleus will decay. The larger the λ, the faster the decay and the shorter the half-life. For tritium, using t₁/₂ = 12.32 years:

λ = 0.693147 / 12.32 yr = 0.05626 yr⁻¹

To convert to seconds, divide by the number of seconds in a year (31,557,600 s):

λ = 0.05626 / 31,557,600 = 1.783 × 10⁻⁹ s⁻¹

Worked Example

Using the calculator defaults (t₁/₂ = 12.32 years):

  1. Compute ln(2) = 0.693147
  2. Divide by the half-life in years: λ = 0.693147 / 12.32 = 0.056261 yr⁻¹
  3. Convert to seconds: 0.056261 / (365.25 × 24 × 3600) = 0.056261 / 31,557,600 = 1.7828 × 10⁻⁹ s⁻¹
  4. Convert to per day: 0.056261 / 365.25 = 0.00015404 d⁻¹

The calculator shows λ = 0.056261 yr⁻¹, λ = 1.7828 × 10⁻⁹ s⁻¹, and λ = 0.00015404 d⁻¹. These match the manual calculation.

Assumptions

  • The half-life is taken as 12.32 years (the standard accepted value for tritium).
  • The decay follows first-order kinetics, which is true for all radioactive decay.
  • One year is defined as 365.25 days (Julian year) for conversion purposes.
  • The decay constant is constant over time; it does not change with temperature, pressure, or chemical state.

What Is Tritium?

Tritium is a radioactive isotope of hydrogen with one proton and two neutrons in its nucleus (mass number 3). It is produced naturally in the upper atmosphere when cosmic rays strike nitrogen-14, and it is also produced artificially in nuclear reactors. Tritium decays by beta emission, converting a neutron into a proton, an electron (beta particle), and an antineutrino. The product is helium-3, a stable isotope.

The beta particle from tritium has a very low average energy (about 5.7 keV) and a maximum energy of 18.6 keV. Because of this low energy, the beta particle cannot penetrate human skin; it is only hazardous if inhaled, ingested, or absorbed into the body. This makes tritium relatively safe to handle with proper precautions, but it is still a radiological hazard.

Why the Decay Constant Matters

The decay constant is the fundamental parameter in the radioactive decay law: N(t) = N₀ e^(−λt), where N(t) is the number of undecayed nuclei at time t, N₀ is the initial number, and e is Euler’s number. This equation describes exponential decay, and it is used to calculate:

  • The activity of a tritium sample: A = λN, where A is in becquerels (decays per second).
  • The age of a sample by measuring the remaining tritium (tritium dating).
  • The required storage time for tritium waste to decay to safe levels.

For example, if you have a sample containing 1 gram of tritium (about 2.0 × 10²³ atoms), the initial activity is λN = (1.7828 × 10⁻⁹ s⁻¹) × (2.0 × 10²³) = 3.57 × 10¹⁴ Bq. After 12.32 years, half of the atoms remain, so the activity is halved.

Common Mistakes and Misconceptions

One common mistake is confusing the decay constant with the half-life. They are inversely related, not equal. A longer half-life means a smaller decay constant, and vice versa. Another mistake is using the wrong time unit: if you calculate λ in s⁻¹, you must use seconds in the exponential decay law. Mixing years and seconds will give wildly wrong results.

A frequent misconception is that tritium’s decay constant changes with temperature or chemical bonding. It does not. The nuclear decay rate is independent of external conditions because it depends only on the strong and weak nuclear forces, not on electron configuration. However, the half-life can be slightly affected by the chemical environment (a few percent difference between tritium gas and tritiated water) due to changes in the electron cloud, but this is negligible for most practical purposes.

How to Use the Decay Constant in Calculations

To use the decay constant, you need to know the number of tritium atoms or the initial activity. Here are the steps:

  1. Determine the number of tritium atoms (N₀) or the initial activity (A₀).
  2. If you have mass, convert to atoms using Avogadro’s number: N₀ = (mass / molar mass) × 6.022 × 10²³. For tritium, molar mass ≈ 3.016 g/mol.
  3. Calculate the activity using A = λN, with λ in s⁻¹.
  4. To find the remaining amount after time t, use N(t) = N₀ e^(−λt) or A(t) = A₀ e^(−λt).

For example, if you start with 1 microgram (10⁻⁶ g) of tritium, the number of atoms is (10⁻⁶ / 3.016) × 6.022 × 10²³ = 1.997 × 10¹⁷ atoms. The activity is (1.7828 × 10⁻⁹) × (1.997 × 10¹⁷) = 3.56 × 10⁸ Bq (about 356 MBq). After 24.64 years (two half-lives), the activity drops to 89 MBq.

Safety and Handling of Tritium

Tritium is a low-energy beta emitter, but it is still regulated as a radioactive material. The main hazard is internal exposure: if tritiated water (HTO) is inhaled or ingested, it distributes throughout the body’s water and can cause cellular damage. The biological half-life of tritium in the human body is about 10 days, meaning it clears relatively quickly. However, chronic exposure should be avoided.

When working with tritium, standard precautions include:

  • Use fume hoods and glove boxes when handling volatile tritiated compounds.
  • Wear appropriate PPE (gloves, lab coat, safety glasses).
  • Monitor for contamination using swipe tests and liquid scintillation counting.
  • Store tritium waste in clearly labeled, shielded containers (though shielding is minimal due to low beta energy).

Always follow your lab’s safety procedures, the safety data sheet (SDS) for the specific tritiated compound, and your supervisor’s instructions. Tritium is used in exit signs, luminous watch dials, and as a tracer in biological research, but it must be handled with respect.

Frequently Asked Questions

What is the exact half-life of tritium?

The accepted half-life of tritium is 12.32 years, with a standard uncertainty of about 0.02 years. This value is determined by measuring the decay rate of pure tritium gas and has been confirmed by multiple experiments.

How do I convert half-life to decay constant?

Use the formula λ = ln(2) / t₁/₂. Make sure the time units match. For tritium, if t₁/₂ = 12.32 years, then λ = 0.693147 / 12.32 = 0.05626 year⁻¹. To get s⁻¹, divide by 31,557,600 seconds per year.

Is tritium dangerous?

Tritium is dangerous only if it enters the body. Its beta particles cannot penetrate the outer layer of skin, so external exposure is not a significant hazard. However, if tritiated water is ingested or inhaled, it can cause cancer risk due to internal radiation. Regulatory limits for tritium in drinking water are very low (e.g., 10,000 Bq/L in the U.S. EPA standard).

What is the difference between tritium and deuterium?

Deuterium (²H) is a stable isotope of hydrogen with one proton and one neutron. Tritium (³H) has one proton and two neutrons and is radioactive. Deuterium is used in nuclear magnetic resonance (NMR) solvents and heavy water, while tritium is used in nuclear weapons, exit signs, and biological tracing.

How long does it take for tritium to decay completely?

Radioactive decay is exponential, so tritium never fully disappears. After 10 half-lives (about 123 years), only 0.1% of the original tritium remains. After 20 half-lives (246 years), it is effectively undetectable (about 1 part per million). For practical purposes, tritium waste is often stored for 100–200 years.

Why is tritium used in exit signs?

Tritium is used in self-luminous exit signs because it emits low-energy beta particles that excite a phosphor coating, producing light without electricity. The long half-life (12.32 years) provides a useful lifespan of 10–20 years, and the low energy makes it safe for public use as long as the glass tube is intact.

Related

Formula used
in t12 | Half-life | years | 12.32 | 0.001
out lam | Decay constant | per year | ln(2) / t12 | 6
out lams | Decay constant | per second | ln(2) / (t12 * 365.25 * 24 * 3600) | 10
out lamd | Decay constant | per day | ln(2) / (t12 * 365.25) | 8

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →