molecalculator

Moles & Molar Mass

Zero-Order Kinetics Formula and Example

Calculator No. 01-6558 · Updated · Formula and assumptions shown below

Concentration remaining 0.0600 mol/L
Half-life
25.00 s
= Initial concentration ÷ (2 × Zero-order rate constant)
Initial concentration
0.1 mol/L
Set in the form below
Zero-order rate constant
0.002 mol/(L·s)
Set in the form below
You enter
Initial concentration (mol/L), Zero-order rate constant (mol/(L·s)), Elapsed time (s)
You get
Concentration remaining (mol/L), Half-life (s)
Rounding
4 dp · 2 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

The zero-order kinetics formula is [A]t = [A]0 − kt, where the reactant concentration falls at a constant rate. This calculator uses the initial concentration, zero-order rate constant, and elapsed time to find the concentration remaining; it also calculates the time required to reach a specified concentration.

Formula

The integrated zero-order rate law is [A]t = [A]0 − kt. In the calculator, [A]t is the concentration remaining at time t, in mol/L; [A]0 is the initial concentration, in mol/L; k is the zero-order rate constant, in mol/(L·s); and t is elapsed time, in seconds. The units of k must match the concentration and time units used.

The rate law is written as −d[A]/dt = k: the rate of disappearance is constant rather than proportional to the concentration. The calculator also reports the zero-order half-life, t1/2 = [A]0/(2k). Because this half-life depends on initial concentration, it is not a fixed property of a zero-order reaction.

Worked Example

Using the default values, the initial concentration is 0.100 mol/L, the rate constant is 0.002 mol/(L·s), and elapsed time is 20 s.

  1. Calculate the concentration consumed: kt = 0.002 mol/(L·s) × 20 s = 0.040 mol/L.
  2. Subtract that amount from the initial concentration: [A]t = 0.100 mol/L − 0.040 mol/L = 0.0600 mol/L.
  3. Calculate the half-life: t1/2 = 0.100 mol/L ÷ (2 × 0.002 mol/(L·s)) = 25.00 s.

The calculator therefore gives a concentration remaining of 0.0600 mol/L and a half-life of 25.00 s.

Assumptions

  • The reaction follows a zero-order rate law over the time interval being considered.
  • The concentration and rate constant refer to the same reacting species and are expressed in compatible units.
  • The model applies only while reactant remains; a negative calculated concentration is not physically meaningful.

How Zero-Order Kinetics Works

For a zero-order reaction, the rate does not change as the reactant concentration changes, at least within the conditions where the model holds. That behavior can occur when a process is limited by a factor that is already saturated or operating at a fixed capacity. For example, a catalyst surface may be occupied by reactant, or an enzyme may be working at its maximum rate when substrate is abundant. These are possible explanations, not proof that a particular process is zero order; the reaction conditions and data must support the model.

The integrated equation predicts a straight-line decrease in concentration with time. A graph of [A] against time has intercept [A]0 and slope −k. By contrast, a first-order reaction has a constant fractional loss rate and its integrated form is ln([A]t) = ln([A]0) − kt; its concentration-versus-time curve is exponential. Reaction order describes an experimentally observed rate relationship, and it should not be inferred merely from the balanced chemical equation.

When to Use the Formula

Use the equation when a measured or otherwise justified rate law is zero order and you want to predict concentration at a later time, or estimate the time to reach a target concentration. To solve for time, rearrange the law:

t = ([A]0 − [A]t)/k

For instance, if concentration decreases from 0.100 mol/L to 0.060 mol/L at 0.002 mol/(L·s), the predicted time is (0.100 − 0.060) mol/L ÷ 0.002 mol/(L·s) = 20 s. This rearrangement is valid for a target between the initial concentration and zero, with a positive rate constant.

In experimental work, a common way to assess the order is to compare how well different integrated plots fit the data: [A] versus time for zero order, ln[A] versus time for first order, or 1/[A] versus time for second order. Use consistent measurements and consider uncertainty and the range of conditions. A line that looks straight over a narrow interval alone may not establish the mechanism or order.

Units, Limits, and Common Mistakes

  • Match time units: if time is entered in seconds, use a rate constant expressed per second. A value in mol/(L·min) must be converted before combining it with seconds.
  • Keep concentration units consistent: if concentrations are in mmol/L, express the rate constant in mmol/(L·s), or convert both to mol/L.
  • Do not continue beyond depletion: the equation reaches zero at t = [A]0/k. At later times, the mathematical line becomes negative, which cannot represent a physical concentration. The calculator flags that invalid result rather than treating it as a real value.
  • Do not confuse half-life with first-order behavior: for zero order, doubling [A]0 doubles the half-life if k stays unchanged. For first order, half-life does not depend on the initial concentration.
  • Do not assume k is universal: its value can depend on conditions such as temperature, catalyst state, or illumination. Use a rate constant measured or specified for the conditions of interest.

Like any rate-law calculation, this is a model, not a substitute for data. Changes in conditions, competing reactions, or a shift away from the regime that produced zero-order behavior can make predictions inaccurate. Round only after calculating, and report enough significant figures to reflect the quality of the input measurements.

Frequently Asked Questions

What is the zero-order kinetics formula?
The integrated rate law is [A]t = [A]0 − kt. It gives the concentration remaining after time t when concentration decreases at a constant rate.

What are the units of a zero-order rate constant?
They are concentration per time, such as mol/(L·s) or mol/(L·min). The chosen time unit must match the one used for elapsed time.

How do you calculate the half-life of a zero-order reaction?
Use t1/2 = [A]0/(2k). Unlike a first-order half-life, this value changes when the initial concentration changes.

Can zero-order concentration be negative?
No. A negative result means the equation has been applied beyond the point where the reactant is depleted, or the inputs are inconsistent. The physical concentration cannot fall below zero.

How can I tell whether a reaction is zero order?
Use concentration-versus-time measurements and test whether [A] plotted against time is approximately linear over the relevant interval. Compare with other integrated rate-law plots and consider measurement uncertainty and changing conditions.

For bench work, follow your lab method, the safety data sheet (SDS), and your supervisor.

Related

Formula used
in a0 | Initial concentration | mol/L | 0.100 | 0
in k | Zero-order rate constant | mol/(L·s) | 0.002 | 0
in t | Elapsed time | s | 20 | 0
out at | Concentration remaining | mol/L | a0 - k * t | 4
out half | Half-life | s | a0 / (2 * k) | 2

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →