A zero-order kinetics plot is a graph of reactant concentration, [A], against time, t; when the reaction is zero order in A, the data form a straight line with slope −k and y-intercept [A]₀. This calculator uses an initial concentration, a zero-order rate constant, and elapsed time to calculate the remaining concentration, the time at which it reaches zero, and the concentration–time line’s slope.
Formula
The integrated zero-order rate law is [A]ₜ = [A]₀ − kt. The calculator’s first result, concentration at time t, is calculated directly from this equation. [A]₀ is the initial concentration in mol/L, [A]ₜ is concentration after elapsed time t in mol/L, k is the zero-order rate constant in mol/(L·s), and t is time in seconds. The plot is the straight line y = b + mx, where y = [A]ₜ, x = t, intercept b = [A]₀, and slope m = −k. The time-to-zero output is [A]₀/k; it is a mathematical extrapolation, not a guarantee that a real reaction remains zero order that long.
Worked Example
Using the calculator’s default values, [A]₀ = 0.100 mol/L, k = 0.002 mol/(L·s), and t = 20 s:
- Calculate the concentration: [A]ₜ = 0.100 − (0.002 × 20) = 0.06000 mol/L.
- Calculate the time to zero: t₀ = 0.100 / 0.002 = 50.00 s.
- Set the plot slope: m = −k = −0.0020 mol/(L·s).
For these assumptions, the plotted equation is [A]ₜ = 0.100 − 0.002t, with concentration in mol/L and time in seconds. At 20 s, the predicted concentration is 0.0600 mol/L.
Assumptions
- The reaction follows a zero-order rate law in the reactant being plotted over the time interval considered.
- The rate constant is constant, and concentration and time use the units shown.
- The expression is used only while predicted concentration is nonnegative. The calculator flags a negative prediction as not computable rather than treating it as a physical concentration.
What Zero-Order Kinetics Means
For a zero-order reaction, the rate of disappearance of A does not depend on the concentration of A, provided the conditions supporting that kinetic regime remain in place. In differential form, −d[A]/dt = k. Integrating gives the linear concentration–time relation used above. The rate constant k has concentration-per-time units, unlike a first-order rate constant, which has inverse-time units.
“Zero order” does not mean that the reaction has no rate, or that every reaction is zero order under all conditions. It describes how the measured rate depends on concentration within a particular experimental range. For example, a surface-catalyzed process may appear zero order when active sites are saturated, or a light-driven process may show an approximately constant rate under fixed illumination. Changing concentration, light, temperature, mixing, or catalyst conditions can end that regime.
How to Make and Read the Plot
Measure the reactant concentration at multiple known times and plot concentration on the vertical axis against time on the horizontal axis. Fit a straight line to the measurements. A useful zero-order pattern is a roughly linear decline, with no systematic curve left in the residuals—the differences between observed and fitted values.
- Slope: −k. A steeper downward slope means faster concentration loss per unit time.
- Vertical intercept: the fitted concentration at t = 0, ideally close to the measured initial concentration.
- Horizontal intercept: the extrapolated time when the line reaches [A] = 0, equal to [A]₀/k. Use this only if the zero-order model remains valid to that point.
If time is in minutes, the fitted slope is in concentration per minute; if concentration is in mmol/L, the rate constant must use mmol/(L·time). Convert units consistently before comparing slopes or applying the calculator. A concentration–time plot is also different from a rate-versus-concentration plot: a zero-order reaction has a constant rate-versus-concentration relationship, while its integrated concentration–time plot falls linearly.
Testing the Reaction Order
A straight concentration–time graph supports zero-order behavior, but it does not prove it by itself. Experimental noise, a short observation window, or a changing measurement response can make different models look similar. A common comparison uses integrated plots:
- Zero order: plot [A] versus time; a straight line has slope −k.
- First order: plot ln[A] versus time; a straight line has slope −k.
- Second order in A: plot 1/[A] versus time; a straight line has slope +k for the simple rate law −d[A]/dt = k[A]².
Compare fit quality and residual patterns across plausible models, and account for measurement uncertainty. The correct rate law may involve multiple reactants or changing conditions, so these three plots are diagnostic options rather than universal rules. A fitted slope should be reported with its units and, where available, uncertainty.
Common Problems and Limits
- Wrong units: using k in mol/(L·min) with t in seconds gives an incorrect result. Convert one of them first.
- Negative predicted concentration: this means the chosen time is beyond the zero-order equation’s physical range. It does not mean concentration is truly negative; the reaction may change regime or approach depletion.
- Assuming a straight line proves the mechanism: a linear fit is evidence for a model over the measured range, not proof of a unique molecular mechanism.
- Using a rate constant from different conditions: k can depend on temperature and other experimental conditions. Use a value measured under comparable conditions.
- Overinterpreting the intercept: the fitted intercept may differ from the first measured concentration because of timing offsets, mixing delays, or measurement bias.
The equation assumes a constant k and a meaningful concentration measurement. If the observed curve bends, the zero-order model may not apply throughout the experiment. For bench work, follow your lab method, the safety data sheet (SDS), and your supervisor.
Frequently Asked Questions
What does the slope of a zero-order kinetics plot represent?
The slope of concentration versus time is −k. Its magnitude is the rate of concentration decrease, with units such as mol/(L·s).
How do you identify zero-order kinetics from a graph?
Plot concentration against time. Approximate linearity, a negative slope, and reasonably unstructured residuals are consistent with zero-order behavior over the tested interval.
What is the integrated rate law for a zero-order reaction?
It is [A]ₜ = [A]₀ − kt, where [A]₀ is initial concentration, [A]ₜ is concentration at time t, and k is the zero-order rate constant.
What are the units of a zero-order rate constant?
They are concentration divided by time, for example mol/(L·s) or mol/(L·min). The exact units depend on the units used for concentration and time.
Can concentration be negative on a zero-order plot?
No. A negative value from the equation signals extrapolation beyond its physical range. Restrict interpretation to times where the reaction model is valid and concentration remains nonnegative.
Related
Formula used
in a0 | Initial concentration | mol/L | 0.100 | 0 in k | Zero-order rate constant | mol/(L*s) | 0.002 | 0 in t | Elapsed time | s | 20 | 0 out a | Concentration at time t | mol/L | a0 - k * t | 4 out tz | Time to zero concentration | s | a0 / k | 2 out slope | Plot slope | mol/(L*s) | -k | 4
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Cell Culture Doubling Time Equation and Calculator24.00 h
- Cell Culture Seeding Density Calculator and Formula4,000.00 cells/cm^2
- Cell Culture Doubling Time Calculator and Formula24.00 h
- CFU From Dilution: Calculate Colony-Forming Units10,000,000 CFU/mL
- Cell Culture Doubling Time Calculator and Formula24.00 h
- Zero Order Release Kinetics Calculator and Explanation5.000 mg/h