At standard atmospheric pressure (101.325 kPa), dry saturated steam at its boiling point of 100 °C has a density of about 0.598 kg/m³. Steam density is not one fixed value at atmospheric pressure: it also depends on temperature, and the figure changes substantially if the steam is superheated or contains liquid-water droplets.
Formula
This calculator estimates steam density using the ideal-gas equation: density equals absolute pressure divided by the product of the specific gas constant for water vapor and absolute temperature.
ρ = p / (Rv T)
- ρ is water-vapor density in kilograms per cubic metre (kg/m³).
- p is absolute pressure in kilopascals, converted to pascals by multiplying by 1,000.
- Rv is the specific gas constant for water vapor, 461.526 J/(kg·K).
- T is absolute temperature in kelvins, calculated as the temperature in °C plus 273.15.
The second output, specific volume, is the reciprocal of density: v = 1/ρ, in cubic metres per kilogram. The calculator requires absolute pressure, not gauge pressure. Its ideal-gas estimate is useful for a quick calculation, but steam tables or a real-fluid equation of state are preferable when precision matters, particularly near saturation.
Worked Example
Using the defaults—101.325 kPa and 100 °C—first convert pressure and temperature:
- p = 101.325 × 1,000 = 101,325 Pa
- T = 100 + 273.15 = 373.15 K
Then calculate density:
ρ = 101,325 / (461.526 × 373.15) = 0.58814 kg/m³
The reciprocal gives specific volume: v = 1 / 0.58814 = 1.7003 m³/kg. The ideal-gas estimate of 0.588 kg/m³ is close to, but not exactly, the steam-table value of approximately 0.598 kg/m³ for saturated steam at 100 °C and standard atmospheric pressure. The difference reflects real-gas behavior near saturation. For the standard saturated-steam value, use a steam table rather than treating the ideal-gas estimate as exact.
Assumptions
- The calculator treats the vapor as an ideal gas and uses a constant water-vapor gas constant of 461.526 J/(kg·K).
- Pressure is absolute, and temperature is entered in degrees Celsius then converted to kelvins.
- The calculation describes water vapor alone. It does not account for liquid droplets, air mixed with steam, or other gases.
- The ideal-gas approximation is not a substitute for property tables when high accuracy is required, especially around the saturation boundary.
What Atmospheric Pressure Means for Steam
Atmospheric pressure is the pressure exerted by the surrounding air. Standard atmospheric pressure is defined as 101.325 kPa, approximately 1.01325 bar or 760 mmHg. Actual local atmospheric pressure varies with weather and elevation, so a calculation for a particular place should use the measured or otherwise appropriate absolute pressure.
At standard atmospheric pressure, liquid water boils at approximately 100 °C. At that temperature, saturated steam and boiling liquid water can exist together in equilibrium. The density of the saturated vapor is about 0.598 kg/m³; saturated liquid water at the same conditions is roughly 958 kg/m³. The vapor is therefore far less dense than the liquid, which is why a given mass of water occupies vastly more space after vaporizing.
Why Steam Density Changes
For a gas at a fixed temperature, increasing pressure generally increases density. At a fixed pressure, increasing temperature generally lowers density because the vapor expands. The ideal-gas equation captures these trends: ρ = p/(RvT). It also shows why pressure and temperature must be specified together to give a meaningful density.
“Steam at atmospheric pressure” does not necessarily mean steam at 100 °C. That temperature is the saturation temperature at standard atmospheric pressure. Steam at the same pressure but above 100 °C is superheated. Its density is lower than saturated steam at 100 °C, and the exact value depends on its temperature. For example, the calculator’s ideal-gas estimate at 120 °C and 101.325 kPa is about 0.560 kg/m³. Steam tables give more accurate values.
Dry Steam, Wet Steam, and Common Confusion
Density values for steam usually refer to water vapor, not a cloud of vapor mixed with suspended liquid droplets. Wet steam contains both phases; its overall density depends on how much liquid is present and how the mixture occupies space. A visible white plume is not proof that all the material is gaseous water vapor: as steam cools and mixes with air, some water condenses into tiny liquid droplets that scatter light.
Another common source of error is confusing density with specific volume. Density is mass per volume, in kg/m³. Specific volume is volume per mass, in m³/kg, and is its reciprocal. At standard atmospheric pressure, saturated steam has a specific volume of roughly 1.67 m³/kg, while the ideal-gas calculator estimate at 100 °C is about 1.70 m³/kg.
When to Use a Calculator or Steam Table
The ideal-gas calculator is suitable for a quick estimate when vapor is well away from the conditions where condensation begins and moderate accuracy is sufficient. Use the actual absolute pressure and temperature; do not enter gauge pressure directly. If a gauge indicates pressure relative to the surrounding atmosphere, add local atmospheric pressure to obtain absolute pressure.
For saturated steam, engineering calculations, or conditions requiring reliable property values, consult a recognized steam table or water-property reference. Those sources account for real-fluid effects and can provide density, specific volume, enthalpy, and other properties. Ensure that the table’s pressure convention and units match your inputs.
Frequently Asked Questions
What is the density of steam at atmospheric pressure?
At standard atmospheric pressure, dry saturated steam at 100 °C has a density of about 0.598 kg/m³. The value differs at other temperatures, and an ideal-gas estimate at 100 °C is about 0.588 kg/m³.
Is steam density always 0.6 kg/m³?
No. That is a useful rounded figure for saturated steam near 100 °C and standard atmospheric pressure. Temperature, pressure, and whether liquid droplets are present all affect the density.
What is the density of superheated steam at atmospheric pressure?
It depends on the superheat temperature. At 120 °C and 101.325 kPa, the ideal-gas estimate is about 0.560 kg/m³. Use steam tables for a more accurate value.
Is steam lighter than air?
At the same temperature and pressure, pure water vapor is less dense than dry air because a water molecule has a lower molar mass than the average air molecule. Real steam plumes cool, mix with air, and may condense, so their motion is not determined by vapor density alone.
How do I convert steam density from kg/m³ to g/L?
The numerical value is the same: 1 kg/m³ equals 1 g/L. Thus 0.598 kg/m³ is also 0.598 g/L.
Related
Formula used
in p | Absolute pressure | kPa | 101.325 | 0 in t | Steam temperature | °C | 100 | -273.15 out rho | Steam density | kg/m³ | (p * 1000) / (461.526 * (t + 273.15)) | 3 out v | Specific volume | m³/kg | 1 / rho | 3
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Pressure-Based vs Density-Based Solvers in CFD
- Pressure-Based vs Density-Based Solvers in CFD
- Fluent Pressure-Based or Density-Based Solver?
- PhET Air Density Lab: What It Shows and How to Use It
- Power Density to E-Field Calculator and Formula
- Pair Density Wave: Meaning, Physics and Open Questions