The dilution table formula is C1V1 = C2V2, where C1 and V1 are the concentration and volume of the stock solution, and C2 and V2 are the concentration and volume of the final diluted solution. To build a dilution table, you solve this equation for the stock volume needed for each desired final concentration, then list those volumes alongside the final volumes and concentrations.
Formula
The core formula for any dilution is:
C1 × V1 = C2 × V2
Where:
- C1 = concentration of the stock (starting) solution, in any unit (mol/L, mM, % w/v, etc.)
- V1 = volume of stock solution you need to take, in any volume unit (mL, L, µL, etc.)
- C2 = concentration of the final diluted solution, in the same unit as C1
- V2 = final total volume after dilution, in the same unit as V1
The units on both sides must match. If C1 is in mol/L and C2 is in mmol/L, convert one first. If V1 is in mL and V2 is in L, convert one before plugging in.
For a dilution table, you typically fix V2 (the final volume you want in each tube, e.g., 10 mL) and vary C2 (the target concentrations). Rearranging gives:
V1 = (C2 × V2) / C1
Then the volume of solvent (water, buffer, media) to add is V2 − V1.
Worked Example
Suppose you have a 1.000 M NaCl stock solution (C1 = 1.000 mol/L) and you want to prepare 100 mL each of 0.500 M, 0.250 M, and 0.125 M NaCl. Using the rearranged formula:
- For 0.500 M: V1 = (0.500 mol/L × 100 mL) / 1.000 mol/L = 50.0 mL. Add 50.0 mL stock to 50.0 mL water.
- For 0.250 M: V1 = (0.250 × 100) / 1.000 = 25.0 mL. Add 25.0 mL stock to 75.0 mL water.
- For 0.125 M: V1 = (0.125 × 100) / 1.000 = 12.5 mL. Add 12.5 mL stock to 87.5 mL water.
Your dilution table would list: target concentration, stock volume, solvent volume, final volume. For the calculator at the top, the default values solve a different but related problem: how much solute (NaCl) to weigh out to make a given volume of solution at a target molarity. With 2.922 g NaCl, molar mass 58.44 g/mol, and final volume 250 mL:
Moles of NaCl = 2.922 g / 58.44 g/mol = 0.05000 mol
Molarity = 0.05000 mol / (250 mL / 1000) = 0.05000 mol / 0.250 L = 0.2000 mol/L
The calculator shows 0.2000 mol/L (200.0 mM). This is the concentration of the stock solution you would then use in a dilution table.
Assumptions
- The formula assumes volumes are additive (final volume = stock volume + solvent volume). This is approximate for many liquids; for precise work, use volumetric flasks and make up to the final mark.
- It assumes the solute does not react with the solvent or change volume significantly upon mixing.
- Concentration units must be consistent on both sides of the equation.
- For serial dilutions, each step uses the previous dilution as the new stock, so the formula is applied repeatedly.
How to Build a Dilution Table
A dilution table is just a list of calculated volumes for a range of target concentrations. Here is a step-by-step method:
- Decide on the stock concentration (C1) and the final volume per tube (V2).
- List the target concentrations (C2) you need – these are often a series like 100, 50, 25, 12.5, 6.25 µM.
- For each target, compute V1 = (C2 × V2) / C1.
- Compute the solvent volume = V2 − V1.
- Record the values in a table with columns: Tube #, Target Concentration, Stock Volume, Solvent Volume, Final Volume.
For example, with a 10 mM stock and 5 mL final volume per tube, to get 2 mM: V1 = (2 mM × 5 mL) / 10 mM = 1 mL. Add 1 mL stock to 4 mL solvent. To get 0.5 mM: V1 = (0.5 × 5) / 10 = 0.25 mL, add 4.75 mL solvent.
Serial Dilution vs. Simple Dilution Table
A simple dilution table lists individual dilutions made directly from the stock. A serial dilution is a sequence where each dilution is made from the previous one, giving a geometric series of concentrations (e.g., 1:2, 1:4, 1:8, 1:16). For a serial dilution, the formula is applied stepwise:
Cn = C0 × (dilution factor)n
Where C0 is the starting concentration, n is the step number, and the dilution factor is the ratio of stock volume to total volume in each step (e.g., for a 1:2 dilution, factor = 0.5). A dilution table for serial dilutions would list the concentration at each step and the volumes used at each transfer.
Common Mistakes and How to Avoid Them
- Unit mismatch: Mixing mL and L, or M and mM, without conversion. Always convert to the same unit before calculating.
- Confusing final volume with solvent volume: V2 is the total final volume, not the amount of solvent to add. Solvent volume = V2 − V1.
- Forgetting that volumes are not perfectly additive: For aqueous solutions, this is usually minor, but for concentrated solutions or organic solvents, use a volumetric flask.
- Using the wrong formula for serial dilutions: In serial dilutions, you do not use the original stock for every step; you use the previous dilution. The formula C1V1 = C2V2 still applies, but C1 is the concentration of the previous tube.
When to Use a Dilution Table
Dilution tables are used in many lab settings:
- Preparing standard curves for spectrophotometry or ELISA – you need a series of known concentrations.
- Making buffer solutions at different molarities from a concentrated stock.
- Diluting a reagent to working concentrations for assays.
- Preparing cell culture media with different antibiotic or drug concentrations.
The table saves time and reduces errors because you calculate all volumes at once, rather than doing each dilution individually.
Limitations and Practical Tips
The formula is exact for ideal solutions, but real solutions can deviate. For most lab work, the error is negligible. However, for very concentrated solutions, the final volume may not equal the sum of the volumes of stock and solvent. In that case, make the solution up to the final volume in a volumetric flask.
When pipetting small volumes (e.g., less than 10 µL), accuracy drops. If your calculated V1 is very small, consider making an intermediate dilution first, or use a larger final volume.
Always label your tubes clearly, and follow your lab method, the safety data sheet (SDS) and your supervisor.
Frequently Asked Questions
How do I calculate the dilution factor?
The dilution factor is the ratio of the final volume to the stock volume: DF = V2 / V1. For example, if you add 1 mL stock to 9 mL solvent, V2 = 10 mL, so DF = 10/1 = 10. This is often written as a 1:10 dilution.
What does a 1:10 dilution mean?
A 1:10 dilution means one part stock plus nine parts solvent, giving a total of ten parts. The concentration of the final solution is one-tenth of the stock. So if you have a 100 mM stock, a 1:10 dilution gives 10 mM.
Can I use the dilution formula for any concentration unit?
Yes, as long as the units for C1 and C2 are the same, and the units for V1 and V2 are the same. You can use mol/L, mM, % w/v, or even mg/mL, but you cannot mix them without converting.
What is the difference between a dilution and a serial dilution?
A simple dilution is a single step from stock to final. A serial dilution is a series of dilutions, each made from the previous one, which gives a geometric progression of concentrations. Serial dilutions are useful for covering a wide range of concentrations with fewer total steps.
How do I make a dilution table for a standard curve?
Choose a stock concentration and a final volume per tube (e.g., 1 mL). List the target concentrations you need (e.g., 0, 1, 2, 5, 10 µg/mL). For each, calculate the stock volume using V1 = (C2 × V2) / C1, then calculate the solvent volume as V2 − V1. Write these in a table.
Why do I get a different answer if I use the calculator above?
The calculator above is for preparing a solution from solid solute, not for diluting a stock. It computes the molarity of a solution made by dissolving a given mass of solute in a final volume. To use it for dilution tables, you would first make a stock solution of known molarity, then use the C1V1 = C2V2 formula separately.
Related
Formula used
in m | Mass of solute | g | 2.922 | 0 in mm | Molar mass | g/mol | 58.44 | 0.001 in v | Final solution volume | mL | 250 | 0.001 out c | Molarity | mol/L | m / mm / (v / 1000) | 4 out cmm | Concentration in millimolar | mM | c * 1000 | 2
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Volume Calculator in mm: Convert & Calculate100,000 mm³
- Volume Calculator in Chemistry: How to Use It0.2000 mol/L
- Volume Calculator Feet and Inches: How to Use It3.12 ft³
- Volume Calculator: Convert ft to Yards1.00 yd³
- Surfboard Volume Calculator JS: How It Works32.4 L
- Volume Calculator cm to Litres: How to Convert2.500 L