The specific gas constant, usually written as Rs or sometimes lowercase r, is the universal gas constant divided by a gas’s molar mass. This calculator finds it from molar mass and returns the value in J/(kg·K), with an optional conversion to kJ/(kg·K).
Formula
The specific gas constant is the universal gas constant divided by molar mass:
Rs = R / M
- Rs is the specific gas constant, in J/(kg·K).
- R is the universal molar gas constant, 8.31446261815324 J/(mol·K).
- M is the gas’s molar mass, in kg/mol. The calculator accepts molar mass in g/mol and converts it to kg/mol by dividing by 1000.
Thus, for an input mm in g/mol, the calculator evaluates Rs = 8.31446261815324 / (mm / 1000). The second output converts J/(kg·K) to kJ/(kg·K) by dividing by 1000. The universal constant is exact in the SI definition; the molar mass you supply determines the practical precision of the result.
Worked Example
For dry air, use the calculator’s default molar mass of 28.97 g/mol. This is a conventional approximate value for air, not a universal molar mass for every gas mixture.
- Convert the molar mass: 28.97 g/mol / 1000 = 0.028970 kg/mol.
- Divide the universal gas constant by that molar mass: 8.31446261815324 J/(mol·K) / 0.028970 kg/mol = 286.9866279 J/(kg·K).
- Rounded to the calculator’s three decimal places, the specific gas constant is 286.987 J/(kg·K).
- Convert to kilojoules: 286.9866279 / 1000 = 0.2869866279 kJ/(kg·K), or 0.286987 kJ/(kg·K) to six decimal places.
Assumptions
- The input is the molar mass of one gas or a defined gas mixture, expressed in g/mol.
- The gas is treated as a single material with a fixed molar mass; composition changes can change the mixture’s value.
- The ideal-gas equation is the context in which the specific gas constant is commonly used. Calculating the constant itself does not require a temperature or pressure measurement.
What the Specific Gas Constant Means
The universal gas constant relates pressure, volume, amount of substance, and absolute temperature in the ideal-gas equation, pV = nRT. That form uses the amount of gas in moles. In engineering and thermodynamics, it is often more convenient to describe a gas by its mass in kilograms. Replacing moles with mass leads to the mass-specific form:
p = ρRsT
Here p is absolute pressure in pascals, ρ is density in kg/m³, and T is absolute temperature in kelvins. The units confirm the relationship: kg/m³ × J/(kg·K) × K equals J/m³, equivalent to Pa. This form is useful when a problem gives mass or density rather than moles and volume.
The word “specific” means “per unit mass.” It distinguishes this constant from the universal gas constant, which is expressed per mole. The specific gas constant is not a new universal constant: it depends on which gas, or gas mixture, is being considered.
How to Choose the Molar Mass
Use the molar mass that matches the substance and composition in your problem. For a pure gas, this is its molar mass from a reliable reference. For a mixture, use the mixture’s mean molar mass, calculated from its component mole fractions when those are known. The 28.97 g/mol default is a common approximate value for dry air; humid air or air with a different composition can have a different value.
- For a pure gas, enter its molar mass in g/mol, not kg/mol.
- For a mixture, enter the effective mean molar mass for the stated composition.
- Keep enough significant figures to suit the data. A result cannot be more reliable than the molar mass and composition used to calculate it.
If you already have a tabulated specific gas constant for the exact gas and units in your problem, using that value may be more practical. Check the units and the stated composition before substituting it.
Common Mix-Ups and Limits
The most common error is confusing the universal gas constant with the specific gas constant. In pV = nRT, use the universal value with n in moles. In p = ρRsT, use the specific value with density in kg/m³. Do not insert one constant into the other equation without converting the variables consistently.
Another frequent mistake is entering 28.97 as though it were kg/mol. The calculator expects g/mol and performs the conversion itself. Entering a molar mass in the wrong unit changes the result by a factor of 1000. Also, temperature in gas-law calculations must be absolute temperature in kelvins, not degrees Celsius; this calculator does not take temperature because temperature is not needed to determine Rs.
The relation Rs = R/M is the standard ideal-gas definition. Real gases can depart from ideal behavior, especially at high pressures or near condensation, so the ideal-gas equation may not accurately predict their state even when the specific gas constant is calculated correctly. The constant alone does not account for those non-ideal effects.
Frequently Asked Questions
What is the specific gas constant for air?
Using 28.97 g/mol as the approximate molar mass of dry air gives about 286.987 J/(kg·K), commonly reported as approximately 287 J/(kg·K). The value can vary slightly with the air’s composition and the molar mass convention used.
What is the difference between R and r?
The universal gas constant R is measured per mole. The specific gas constant, often written Rs and sometimes r, is measured per unit mass and equals R divided by molar mass. Notation varies by textbook, so check how a source defines its symbol.
What are the units of the specific gas constant?
Its SI units are J/(kg·K), equivalent to m²/(s²·K). It is also often shown in kJ/(kg·K); divide the value in joules by 1000 to convert.
Does the specific gas constant change with temperature?
For a gas with fixed composition, its specific gas constant is set by the universal constant and molar mass, so it does not change with temperature. A mixture’s value can change if its composition changes.
Can I use this value for a real gas?
The constant is still defined from the gas’s molar mass, but the simple ideal-gas equation may not describe a real gas accurately under all conditions. For substantial non-ideal behavior, use an appropriate real-gas model and its required properties.
Related
Formula used
in mm | Molar mass | g/mol | 28.97 | 0.000001 out rs | Specific gas constant | J/(kg·K) | 8.31446261815324 / (mm / 1000) | 3 out rsk | Specific gas constant | kJ/(kg·K) | rs / 1000 | 6
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Liters to Cubic Meters: Conversion and Examples0.001000 m³
- Normal Cubic Meter to Liters Calculator1,000.00 L
- Qt to Liters Conversion: US and Imperial Quarts0.946353 L
- Meters to Liters Formula: Convert Length to Volume?1,000.000 L
- Meters to Litres: Why Length Alone Is Not Enough1,000.00 L
- Cubic Meters per Hour to Liters per Second0.2778 L/s