Specific heat capacity at constant volume, written cv, is the heat required to raise the temperature of one unit of mass of a substance by one kelvin while its volume is held fixed. This calculator finds cv from heat added, sample mass, and temperature change; enter joules, kilograms, and degrees Celsius or kelvins to get J/(kg·K).
Formula
For a fixed-volume process, the specific heat capacity is the heat transferred per unit mass divided by the resulting temperature change:
cv = Q / (m ΔT)
- cv is specific heat capacity at constant volume, in joules per kilogram per kelvin (J/(kg·K)).
- Q is heat transferred to the sample, in joules (J).
- m is sample mass, in kilograms (kg).
- ΔT is the temperature change, in kelvins (K). A temperature interval of 1 K has the same size as an interval of 1 °C.
The calculator uses this equation in its simple calorimetric form. It assumes the reported heat goes into the sample and that cv is effectively constant across the measured temperature interval. If heat escapes to the surroundings, or the container itself absorbs substantial energy, the result from the basic equation will not represent the substance alone unless those effects are corrected.
Worked Example
Using the calculator’s default values, Q = 1000 J, m = 0.5 kg, and ΔT = 10 K:
1. Calculate the heat absorbed per kilogram: 1000 J / 0.5 kg = 2000 J/kg.
2. Divide by the temperature change: 2000 J/kg / 10 K = 200 J/(kg·K).
The calculator reports 200 J/(kg·K). This is the result of the stated inputs and assumptions, not a reference value for a particular named material.
Assumptions
- The sample’s volume remains fixed while the heat transfer is considered.
- Heat loss to the surroundings and energy absorbed by any container are negligible or have already been corrected.
- The substance is sufficiently uniform for one mass and temperature change to describe the sample.
- Specific heat capacity is treated as constant over the measured temperature interval.
- Heat added is positive and the sample warms, so the entered temperature change is positive.
What Constant Volume Means
Heat capacity describes how much energy is needed to change temperature, but the measured value depends on what the substance is allowed to do as it is heated. “At constant volume” means the material is constrained so its volume does not change appreciably. For a gas in a rigid, sealed container, heating raises its temperature and pressure while the container volume remains fixed.
For a solid or liquid, the distinction between constant-volume and constant-pressure heat capacities is often small in ordinary conditions, though it is not always zero. For a gas, it is important: at constant pressure, an expanding gas can do work on its surroundings, so more heat is generally needed for the same temperature rise than when the gas is held at constant volume.
Specific heat capacity is an intensive property: it does not double merely because the sample is twice as large. Total heat capacity, by contrast, applies to a particular object. For a uniform sample, its total heat capacity is approximately m cv, in J/K. The formula above divides that total energy requirement by mass to give a value per kilogram.
When to Use This Calculation
Use the calculator when a measured or specified heat input, sample mass, and temperature rise are available and the process can reasonably be treated as constant-volume. It can also be rearranged for planning or checking a simple energy balance:
- To find heat required: Q = m cv ΔT.
- To find the temperature rise: ΔT = Q / (m cv).
- To find the sample mass: m = Q / (cv ΔT).
These rearrangements use the same assumptions as the calculator. A measured value may vary with temperature, phase, pressure, composition, and the precise experimental method. For a broad temperature range, use a reliable property table or temperature-dependent model rather than assuming one constant value. When working with laboratory samples, follow your lab method, the safety data sheet (SDS), and your supervisor.
Constant Volume Versus Constant Pressure
The symbols cv and cp distinguish heat capacities per unit mass at constant volume and constant pressure. For an ideal gas, the corresponding molar heat capacities obey Cp − Cv = R, where R = 8.31446261815324 J/(mol·K) is the molar gas constant. This relation is for molar heat capacities of an ideal gas; it should not be applied directly to mass-specific values without converting units using the gas’s molar mass.
In a rigid container, the boundary does no expansion work because its volume does not change. At constant pressure, a gas can expand during heating and perform work. That difference explains why cp is greater than cv for an ideal gas. The distinction is not a claim that one value is universally more useful: choose the one matching the physical constraint and the property data available.
Units, Measurements, and Common Errors
Keep units consistent. The calculator expects heat in joules, mass in kilograms, and a temperature interval in kelvins or degrees Celsius. If heat is supplied in kilojoules, multiply by 1000 to convert to joules; if mass is in grams, divide by 1000 to convert to kilograms. Because temperature differences have equal numerical sizes in kelvins and Celsius degrees, ΔT = 10 °C is numerically 10 K. Absolute temperatures do not work this way: converting an absolute Celsius temperature to kelvins requires adding 273.15.
- Confusing heat capacity and specific heat: J/K describes a whole object; J/(kg·K) is per unit mass.
- Using the wrong process constraint: a constant-pressure table value may not be appropriate for a rigid-volume experiment.
- Ignoring container heat capacity: a calorimeter, vessel, or sensor can absorb energy and bias the calculated sample value.
- Using net heat incorrectly: Q should be the heat transferred to the sample, with losses or other energy paths accounted for if significant.
- Overinterpreting precision: a result with many digits is not more accurate than the measurements of heat, mass, and temperature allow.
Frequently Asked Questions
What is the unit of specific heat capacity at constant volume?
In SI units it is J/(kg·K). Molar heat capacity at constant volume is instead expressed in J/(mol·K); the two quantities differ by the substance’s molar mass.
Is cv the same as cp?
No. cv applies when volume is fixed, while cp applies when pressure is fixed. They are often close for many solids and liquids, but differ notably for gases.
Can I use a Celsius temperature change?
Yes. A change of 1 °C equals a change of 1 K, so enter the numerical temperature difference directly. Do not use an absolute Celsius temperature in place of ΔT.
Why is a gas’s cp greater than its cv?
At constant pressure, a gas can expand as it warms and use some supplied energy to do work. At fixed volume, that expansion work does not occur. For an ideal gas, the molar difference is the gas constant R.
Does specific heat capacity change with temperature?
It can. The single-value equation is a useful approximation over a limited interval. For large temperature changes or phase transitions, use temperature-dependent data and account for latent heat where applicable.
What if the sample loses heat during the measurement?
Then the measured heat input is not the heat absorbed by the sample, so the calculated value may be too low or otherwise biased. Improve insulation or apply a validated correction for heat exchange and apparatus heat capacity.
Related
Formula used
in q | Heat added | J | 1000 | 0 in m | Sample mass | kg | 0.5 | 0 in dt | Temperature change | K | 10 | 0 out cv | Specific heat capacity at constant volume | J/(kg·K) | q / (m * dt) | 2
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Liters to Cubic Meters: Conversion and Examples0.001000 m³
- Normal Cubic Meter to Liters Calculator1,000.00 L
- Qt to Liters Conversion: US and Imperial Quarts0.946353 L
- Meters to Liters Formula: Convert Length to Volume?1,000.000 L
- Meters to Litres: Why Length Alone Is Not Enough1,000.00 L
- Cubic Meters per Hour to Liters per Second0.2778 L/s