The decay constant (symbol λ, lambda) is measured in reciprocal time units, most commonly s⁻¹ (per second) in SI, though min⁻¹, h⁻¹, d⁻¹, and yr⁻¹ are also used. It represents the probability per unit time that a single unstable nucleus will decay, so its unit is simply 1/time.
Formula
The decay constant appears in the exponential decay law:
N(t) = N₀ · e^(−λt)
- N(t) – amount of radioactive substance remaining after time t (mol, or any unit of count)
- N₀ – initial amount at t = 0 (same unit as N(t))
- λ – decay constant (s⁻¹, min⁻¹, etc.)
- t – elapsed time (s, min, etc., matching the unit of λ)
Because λ has units of 1/time, the product λt is dimensionless (no units). That is what allows it to appear as an exponent.
Worked Example
Using the calculator defaults: N₀ = 1 mol, t = 100 s, λ = 0.0001 s⁻¹.
- Calculate the exponent: −λt = −(0.0001 s⁻¹)(100 s) = −0.01 (dimensionless).
- Compute e^(−0.01) ≈ 0.9900498.
- Multiply by N₀: 1 mol × 0.9900498 = 0.990050 mol remaining.
- Fraction remaining = 0.9900498 ≈ 0.9900 (rounded to 4 decimal places).
- Half-life = ln(2)/λ = 0.693147 / 0.0001 s⁻¹ = 6931.47 s ≈ 6.93 × 10³ s.
The calculator shows 0.990050 mol for the remaining amount, matching the step-by-step result.
Assumptions
- The decay follows first-order kinetics – the rate is proportional to the amount present.
- λ is constant over time; it does not change with temperature, pressure, or chemical state (for most nuclear decays).
- The sample is large enough that statistical fluctuations are negligible.
Why the Unit Is 1/Time
Radioactive decay is a random, probabilistic process. For a single nucleus, λ is the probability per unit time that it will decay. If λ = 0.01 s⁻¹, each nucleus has a 1% chance of decaying in the next second. Since probability is dimensionless, dividing it by time gives units of 1/s. This is why you will see λ written as s⁻¹, min⁻¹, or yr⁻¹, never as just “per second” in words.
The same unit applies to any first-order process, not just radioactivity. Chemical reactions that are first order (like some decompositions) have rate constants with units of 1/time. The decay constant is essentially a first-order rate constant.
Relationship to Half-Life and Mean Life
Three quantities describe how fast a radioactive sample decays, and they all carry the same information:
- Decay constant λ – probability per unit time (unit: s⁻¹)
- Half-life t₁/₂ – time for half the sample to decay (unit: s) – related by t₁/₂ = ln(2)/λ
- Mean lifetime τ – average time a nucleus survives (unit: s) – related by τ = 1/λ
For example, carbon-14 has a half-life of 5730 years, so its decay constant is λ = ln(2)/5730 yr ≈ 1.21 × 10⁻⁴ yr⁻¹. In SI units, that is about 3.83 × 10⁻¹² s⁻¹. The mean lifetime is 1/λ ≈ 8267 years.
Notice that a longer half-life gives a smaller decay constant. A stable nucleus would have λ = 0 (never decays).
Common Mistakes and Unit Mix-Ups
The most frequent error is mixing time units. If λ is given in s⁻¹, you must use time in seconds. If you plug in minutes, your result will be off by a factor of 60. Always convert to matching units before calculating.
Another mistake is confusing λ with the activity (A). Activity is the total number of decays per second in a sample, measured in becquerels (Bq, 1 decay/s) or curies (Ci). The relationship is A = λN, where N is the number of undecayed nuclei. If you have 1 mole of a substance (6.022 × 10²³ nuclei) with λ = 0.0001 s⁻¹, the initial activity is 6.022 × 10¹⁹ Bq – a huge number. The decay constant is per nucleus, not per sample.
Also, do not confuse λ with the half-life. They are reciprocally related (through ln 2). A common misconception is that λ = 0.5/t₁/₂; the correct factor is ln(2) ≈ 0.693, not 0.5.
Choosing the Right Time Unit
In practice, the unit of λ is chosen to make numbers convenient. For isotopes with very long half-lives (like uranium-238, t₁/₂ = 4.5 × 10⁹ years), λ is often given in yr⁻¹ (≈1.55 × 10⁻¹⁰ yr⁻¹). For medical isotopes with half-lives of hours (technetium-99m, t₁/₂ = 6 hours), λ is given in h⁻¹ (≈0.1155 h⁻¹). For very short-lived particles, s⁻¹ or even ms⁻¹ is used.
When doing calculations, match the unit of time in your problem. If you are given a half-life in days, compute λ in d⁻¹ and use time in days. The calculator above uses seconds, but you can adapt by converting λ and t to the same unit first.
Limits of the Formula
The exponential decay law assumes that λ is constant. This is true for most nuclear decays, but not for all processes that look like decay. For example, if a sample is being replenished (as in a nuclear reactor), the net change is not a simple exponential. Also, for extremely small samples (a few atoms), the exponential law gives the average behavior; actual decay is random and you might see fluctuations. The law is statistical and works best for large numbers of nuclei.
For chemical reactions, the decay constant can change with temperature (Arrhenius equation), so it is not truly constant. For radioactive decay, temperature and pressure have no measurable effect on λ.
Frequently Asked Questions
Is the decay constant the same as the rate constant?
Yes, for a first-order process. In chemical kinetics, a first-order reaction has rate = k[A], and k has units of 1/time. The decay constant λ is exactly that k for radioactive decay. Both describe the probability per unit time of a single event (decay or reaction).
How do I convert a half-life to a decay constant?
Use λ = ln(2) / t₁/₂. For example, if t₁/₂ = 10 days, λ = 0.693 / 10 d = 0.0693 d⁻¹. If you need it in s⁻¹, convert days to seconds first: 10 d × 86400 s/d = 864000 s, then λ = 0.693 / 864000 s ≈ 8.02 × 10⁻⁷ s⁻¹.
Can the decay constant be negative?
No. A negative λ would imply that the amount increases over time, which is not decay. λ is always positive (or zero for a stable nucleus). If you ever get a negative value, you likely used a wrong formula or sign.
What is the difference between decay constant and activity?
Decay constant (λ) is a property of a single nucleus – the probability per second it will decay. Activity (A) is the total decays per second for a sample, equal to λ times the number of nuclei (A = λN). Activity depends on how much material you have; λ does not.
Why is the unit written as s⁻¹ instead of 1/s?
Both are correct. The negative exponent notation (s⁻¹) is standard in SI and scientific writing because it avoids fractions in text. It means “per second.” You will also see min⁻¹, h⁻¹, and yr⁻¹.
Related
Formula used
in m | Initial amount | mol | 1 | 0 in t | Time elapsed | s | 100 | 0 in l | Decay constant λ | s⁻¹ | 0.0001 | 0 out n | Remaining amount | mol | m * exp(-l * t) | 6 out frac | Fraction remaining | - | exp(-l * t) | 4 out hl | Half-life | s | ln(2) / l | 2
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Serial Dilution Calculation Examples0.2000 mol/L
- Serial Dilution: How It Works & Why It Matters1.000 × 10−5 mol/L
- Serial Dilution A Level Biology: How To Do It30
- Serial vs Simple Dilution: Key Differences0.2000 mol/L
- Milton Tablet Dilution: Mixing Guide0.2000 mol/L
- qPCR Serial Dilution Standard Curve: How to Build One100,000 copies/µL