molecalculator

Moles & Molar Mass

Half-Life Formula Using e: Decay & Calculation

Calculator No. 01-7058 · Updated · Formula and assumptions shown below

Remaining amount 42.0448 g
Fraction remaining
0.4204
Result, rounded to 4 decimal places
Decay constant λ
0.086643 1/h
Result, rounded to 6 decimal places
Elapsed time
10 h
Set in the form below
You enter
Elapsed time (h), Half-life (h), Initial amount (g)
You get
Remaining amount (g), Fraction remaining, Decay constant λ (1/h)
Rounding
4 dp · 6 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

The half-life formula using e is N(t) = N₀ × e–λt, where λ (the decay constant) equals ln(2) divided by the half-life (t½). This exponential decay equation lets you calculate how much of a radioactive substance remains after any time t, not just at whole multiples of the half-life.

Formula

The exponential decay formula is written as:

N(t) = N₀ × e–λt

where:

  • N(t) = amount remaining after time t (grams, moles, atoms, or any unit of quantity)
  • N₀ = initial amount at t = 0 (same unit as N(t))
  • e = Euler’s number, approximately 2.71828 (the base of natural logarithms)
  • λ = decay constant, with units of 1/time (e.g., s–1, h–1, yr–1)
  • t = elapsed time (same time unit as λ)

The decay constant λ is related to the half-life t½ by:

λ = ln(2) / t½

Here, ln(2) ≈ 0.693147. This relationship comes from setting N(t½) = N₀/2 in the decay equation and solving for λ.

Worked Example

Using the default values from the calculator: initial amount N₀ = 100 g, half-life t½ = 8 h, elapsed time t = 10 h.

Step 1: Calculate the decay constant λ.

λ = ln(2) / t½ = 0.693147 / 8 h = 0.0866434 h–1

Step 2: Plug into the exponential formula.

N(10) = 100 × e–(0.0866434 × 10) = 100 × e–0.866434

Step 3: Evaluate the exponential.

e–0.866434 ≈ 0.420448

Step 4: Multiply by the initial amount.

N(10) = 100 × 0.420448 = 42.0448 g

The calculator rounds to 4 decimal places, giving 42.0448 g. After 10 hours, about 42 g of the original 100 g remains.

Assumptions

  • The decay follows first-order kinetics (the rate is proportional to the amount present).
  • The half-life is constant over time (not affected by temperature, pressure, or chemical state).
  • No new atoms of the isotope are being produced during the decay.
  • The sample is pure and the measurement is made at a single instant.

Why Use e Instead of Powers of 1/2?

Many introductory texts write the half-life formula as N(t) = N₀ × (1/2)t/t½. That form is simpler for whole-number half-lives, but the e-based form is more fundamental. The differential equation dN/dt = –λN has the solution N = N₀e–λt; the constant e emerges naturally from calculus. Using e also makes it easy to:

  • Calculate the amount at any time, not just multiples of the half-life.
  • Combine multiple decay processes (e.g., a substance that decays and is also removed by excretion) by adding decay constants.
  • Convert to other time constants, such as the mean lifetime τ = 1/λ.

The (1/2) form is just a special case: since e–λt = (e–λ)t and e–λt½ = 1/2, you can rewrite it as (1/2)t/t½. Both are mathematically identical, but the e form connects directly to the underlying physics and to differential equations.

How to Use the Calculator

Enter any three of the four values (initial amount, half-life, elapsed time, or remaining amount) and the calculator will compute the missing one. For example, if you know the half-life of iodine-131 is 8.02 days and you start with 50 mg, you can find how much remains after 20 days by entering t = 20, t½ = 8.02, N₀ = 50. The calculator uses the e formula directly.

To find the time when a certain fraction remains, you can rearrange the formula:

t = (t½ / ln(2)) × ln(N₀ / N(t))

For instance, to find when 10 g of a 100 g sample remains (N₀/N = 10), with t½ = 8 h:

t = (8 / 0.693147) × ln(10) = 11.5416 × 2.30259 ≈ 26.58 h

Common Mistakes and Misconceptions

  • Unit mismatch: The elapsed time and half-life must be in the same unit. If t is in days and t½ in hours, convert first (e.g., 1 day = 24 h).
  • Confusing λ with t½: λ is the decay constant (probability of decay per unit time), while t½ is the time for half to decay. They are inversely related, not equal.
  • Using ln(2) vs. log10(2): The formula uses the natural logarithm (base e), not common logarithm (base 10). ln(2) ≈ 0.693, log10(2) ≈ 0.301. Using the wrong one gives a wrong λ by a factor of 2.303.
  • Adding half-lives linearly: After two half-lives, the remaining fraction is (1/2)² = 1/4, not 0. The decay is multiplicative, not additive.
  • Forgetting that N₀ and N(t) must be in the same unit: If you start with grams, the result is in grams; if you use moles, the result is in moles.

Real-World Applications

The exponential decay formula is used in many fields beyond nuclear physics:

  • Carbon dating: Carbon-14 has a half-life of 5,730 years. By measuring the remaining ¹⁴C in an organic sample, archaeologists calculate its age using the e formula.
  • Medical imaging: Technetium-99m (t½ = 6.01 h) is used in diagnostic scans. Hospitals calculate how much activity remains when the dose is prepared versus when it is injected.
  • Pharmacokinetics: Drug elimination from the body often follows first-order kinetics. The half-life of a drug (e.g., 4 h for caffeine) helps determine dosing intervals.
  • Capacitor discharge: In electronics, the voltage across a discharging capacitor decays as V(t) = V₀e–t/RC, where RC is the time constant (analogous to 1/λ).
  • Cooling: Newton’s law of cooling uses a similar exponential form, though the ambient temperature adds a constant offset.

In every case, the e formula provides a continuous model that matches observed behavior across chemistry, physics, biology, and engineering.

Limitations of the Formula

The simple exponential decay formula assumes a closed system with no production of the isotope. In reality, some decay chains produce the isotope as a daughter product (e.g., radon-222 is produced by radium-226 decay). In such cases, the amount of the daughter grows and then decays, requiring a more complex set of equations (Bateman equations). The formula also assumes the half-life is constant; for most practical purposes this is true, but extreme conditions (such as very high pressure or temperature) can slightly alter decay rates for electron-capture isotopes, though these effects are minuscule. For very short half-lives (fractions of a second), measurement uncertainty becomes significant, and for very long half-lives (billions of years), the formula still works but the precision of the half-life itself limits accuracy.

Frequently Asked Questions

Why is e used in the half-life formula?
Because the decay process is first-order: the rate of decay is proportional to the amount present. The differential equation dN/dt = –λN has the solution N = N₀e–λt. The number e is the base of natural logarithms and appears naturally when solving this equation. Using e makes the math consistent with calculus and allows easy manipulation of the equation.

What is the difference between half-life and decay constant?
The decay constant λ is the probability per unit time that a single atom will decay. The half-life t½ is the time required for half of the atoms to decay. They are related by λ = ln(2)/t½. A larger λ means a shorter half-life and faster decay.

Can I use the formula for non-radioactive processes?
Yes, the same exponential decay equation applies to any first-order process: drug clearance from the body, capacitor discharge, chemical reactions that are first-order, and even population decline under certain conditions. The half-life is a general concept, not limited to radioactivity.

How do I calculate the age of a sample using half-life?
Rearrange the formula to solve for t: t = (t½ / ln(2)) × ln(N₀/N(t)). For carbon dating, you need the initial ¹⁴C ratio (assumed constant) and the measured remaining ratio. For example, if a sample has 25% of the ¹⁴C of a living organism, then N₀/N = 4, and t = (5730 / 0.693) × ln(4) ≈ 11,460 years.

What if the half-life is given in minutes but my time is in hours?
Convert one to the other before using the formula. For instance, if t½ = 30 min and t = 2 h, convert t to 120 min or t½ to 0.5 h. The formula requires consistent time units for λ and t.

Does temperature affect half-life?
For most radioactive decays, temperature has no measurable effect because nuclear processes are independent of chemical environment. However, for electron-capture decay (a rare mode), the decay rate can be slightly affected by the electron density near the nucleus, which can be altered by extreme pressure or temperature. For all practical purposes, half-lives are considered constant.

Related

Formula used
in t | Elapsed time | h | 10 | 0
in th | Half-life | h | 8 | 0.0000001
in n0 | Initial amount | g | 100 | 0
out n | Remaining amount | g | n0 * exp(-ln(2) * t / th) | 4
out frac | Fraction remaining | - | exp(-ln(2) * t / th) | 4
out lambda | Decay constant λ | 1/h | ln(2) / th | 6

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →