Dilution calculations show how much concentrated solution and solvent are needed to make a target concentration and final volume. Enter the stock concentration, desired concentration, and final volume to calculate the stock volume required; the result uses the same concentration units for both concentrations.
Formula
The standard dilution equation is CstockVstock = CtargetVfinal. Rearranged to find the volume of stock: Vstock = (Ctarget / Cstock) × Vfinal. The calculator also estimates diluent volume as Vfinal − Vstock, and the dilution factor as Cstock / Ctarget.
- Cstock is the stock solution concentration in mol/L.
- Ctarget is the desired final concentration in mol/L.
- Vstock is the stock solution volume to measure, in mL.
- Vfinal is the total final solution volume, in mL.
- Vdiluent is the approximate volume of diluent, in mL.
- Dilution factor is the ratio of stock concentration to target concentration; it has no units.
Both concentrations must use the same units, and both volumes must use the same units. This calculator reports volumes in mL, so no mL-to-L conversion is needed in its equations. The target concentration must be positive and no greater than the stock concentration for an ordinary dilution.
Worked Example
Using the calculator defaults: Cstock = 1 mol/L, Ctarget = 0.1 mol/L, and Vfinal = 100 mL.
- Calculate the stock volume: Vstock = (0.1 mol/L ÷ 1 mol/L) × 100 mL = 10 mL.
- Estimate the diluent volume: Vdiluent = 100 mL − 10 mL = 90 mL.
- Calculate the dilution factor: 1 mol/L ÷ 0.1 mol/L = 10.
The result is 10.00 mL of stock, diluted to a final volume of 100 mL. The calculated 90.00 mL of diluent is an estimate; in careful preparation, add diluent until the total solution reaches the specified final volume.
Assumptions
- The stock and target concentrations refer to the same dissolved substance and use the same concentration basis.
- The final volume means the volume of the complete solution, not the volume of solvent added.
- The solution is sufficiently dilute for the stated concentrations and volumes to be used directly; volume contraction or expansion is not separately corrected.
- This is arithmetic for study and lab planning, not a substitute for a validated method. For bench work, follow your lab method, the safety data sheet (SDS) and your supervisor.
Step-by-Step
- Identify the stock and target concentrations. Use the concentration printed for the stock and the concentration required by your experiment. Check whether each is molarity, mass concentration, or another measure.
- Make concentration units match. For example, convert both values to mol/L or both to mmol/L before calculating. Do not compare a value in mg/mL directly with one in mol/L. A conversion between mass and molar concentration requires the substance’s molar mass.
- Choose the desired final volume. This is the total volume of diluted solution you need, not the amount of water or other diluent you intend to add.
- Check that the target is achievable by dilution. A simple dilution can lower concentration but cannot raise it. The target should be positive and no higher than the stock concentration.
- Calculate the stock volume. Divide target concentration by stock concentration, then multiply by final volume. Keep the units consistent so the answer is a volume.
- Calculate the approximate diluent volume if useful. Subtract the stock volume from the final volume. This is a planning estimate, not always the exact amount of solvent to add.
- Prepare to the final volume. In a suitable graduated vessel, measure the stock and add diluent until the total solution reaches the required final volume. Mix as specified by your lab method. Do not assume that adding the calculated diluent volume always produces exactly the intended final volume.
- Record the preparation. Note the stock concentration, target, final volume, calculated stock volume, units, and any relevant method details. Use a suitable measuring device and the precision required by the work.
Common Mistakes
- Mixing units: The equation only works directly when the concentration units match and the volume units match. Convert first, and show the conversion in your working.
- Using solvent volume instead of final volume: “Make to 100 mL” means the total solution ends at 100 mL; it does not mean add 100 mL of solvent to the stock.
- Reversing the concentration ratio: For a target weaker than the stock, the stock volume should be less than the final volume. If the calculated amount is larger, recheck the ratio and inputs.
- Rounding too early: Keep extra digits during calculation and round only the volume you will measure, based on the measuring equipment and method.
- Assuming volumes are perfectly additive: Mixing can change total volume, particularly for some solutions. Reaching the specified final volume is more reliable than adding a calculated solvent volume.
Tips
- Write units beside every given value and each intermediate result.
- Do a quick reasonableness check: a tenfold dilution uses one part stock per ten parts final solution, such as 10 mL stock in a final volume of 100 mL.
- For a serial dilution, calculate each stage separately. The overall dilution factor is the product of the individual factors, provided each transfer and final volume is correct.
- When making several samples, calculate each final volume and account for any extra volume needed for transfers or repeat measurements.
Troubleshooting
The stock volume is greater than the final volume: Check whether the target concentration is above the stock concentration, whether the concentration ratio was reversed, and whether units match. A target above stock requires a more concentrated starting solution or a different preparation method, not dilution.
The answer seems implausibly tiny or large: Review prefixes such as milli (10−3) and micro (10−6), and confirm that a mass concentration was not mistaken for molarity. Convert to base units on paper if necessary.
The prepared solution is not at the intended concentration: Check the stock label, the measured stock volume, the final-volume mark, mixing, and whether the stock was prepared or stored according to its method. Do not correct an uncertain preparation by guessing; consult the applicable protocol or supervisor.
The target cannot be reached accurately with the available equipment: Consider a larger final batch or a carefully planned serial dilution if the method permits it. Each extra transfer can add uncertainty, so use the simplest validated approach.
Frequently Asked Questions
What is the dilution equation?
CstockVstock = CtargetVfinal. It relates the stock concentration and volume to the concentration and total volume after dilution.
Can I use the equation with mg/mL or percentages?
Yes, if both concentration values use the same units and the same definition. Do not mix mass-based and molar concentrations without converting using the correct molar mass.
Is the diluent volume the same as the final volume?
No. The final volume includes the stock solution. The diluent amount is approximately final volume minus stock volume, but preparing to the final volume is generally the correct endpoint.
How do I calculate a tenfold dilution?
Divide the stock concentration by the target concentration to get a factor of 10. The stock occupies one-tenth of the final volume; dilute to the total volume required.
Can dilution make a solution more concentrated?
No. Dilution lowers concentration. To reach a target above the stock concentration, use a suitable more concentrated stock or another validated preparation calculation.
How do I calculate a serial dilution?
Apply the dilution equation at each step. Multiply the stepwise dilution factors to find the overall factor, then verify the concentration after each stage and account for transfer volumes.
Related
Formula used
in cs | Stock concentration | mol/L | 1 | 0 in ct | Target concentration | mol/L | 0.1 | 0 in vf | Final solution volume | mL | 100 | 0 out vs | Stock solution volume | mL | cs / ct * vf | 2 out vd | Diluent volume, approximate | mL | vf - vs | 2 out factor | Dilution factor | - | cs / ct | 2
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Liters to Cubic Meters: Conversion and Examples0.001000 m³
- Normal Cubic Meter to Liters Calculator1,000.00 L
- Qt to Liters Conversion: US and Imperial Quarts0.946353 L
- Meters to Liters Formula: Convert Length to Volume?1,000.000 L
- Meters to Litres: Why Length Alone Is Not Enough1,000.00 L
- Cubic Meters per Hour to Liters per Second0.2778 L/s