Exponential Decay Half-Life: Formula & How to Calculate

Calculator No. 01-6974 · Updated · Formula and assumptions shown below

Half-life t₁/₂ 3.3333 s
Decay constant λ
0.207944 1/s
Result, rounded to 6 decimal places
Initial quantity N₀
1000
Set in the form below
Quantity after time t N(t)
125
Set in the form below
You enter
Initial quantity N₀, Quantity after time t N(t), Elapsed time t (s)
You get
Half-life t₁/₂ (s), Decay constant λ (1/s)
Rounding
4 dp · 6 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

Exponential decay half-life is the time required for a quantity undergoing exponential decay to reduce to half its initial value. To calculate it, you use the formula t1/2 = ln(2) / λ, where λ is the decay constant; if you know the decay constant, you can directly find the half-life, and vice versa.

Formula

The exponential decay equation is:

N(t) = N₀ · e−λt

Where:

  • N(t) = quantity remaining after time t (same units as N₀)
  • N₀ = initial quantity (any unit, as long as it matches N(t))
  • λ = decay constant (units of 1/time, e.g., s−1, min−1, yr−1)
  • t = elapsed time (same time unit as λ)

Setting N(t) = N₀/2 and solving gives the half-life:

t1/2 = ln(2) / λ

Since ln(2) ≈ 0.693147, the half-life is approximately 0.693 divided by the decay constant. The calculator above uses the more general form t1/2 = t · ln(2) / ln(N₀/N(t)), which works even if you don’t know λ directly.

Worked Example

Suppose you start with 1000 atoms of a radioactive isotope. After 10 seconds, only 125 atoms remain. What is the half-life?

  1. Identify the known values: N₀ = 1000, N(t) = 125, t = 10 s.
  2. Compute the ratio N₀/N(t) = 1000/125 = 8.
  3. Take the natural log: ln(8) = 2.07944.
  4. Multiply elapsed time by ln(2): 10 × 0.693147 = 6.93147.
  5. Divide: t1/2 = 6.93147 / 2.07944 = 3.3333 s.

So the half-life is 3.333 seconds. The decay constant is λ = ln(2)/3.3333 = 0.2079 s−1. Notice that after 3 half-lives (10 s / 3.333 s), the quantity is 1000 × (1/2)3 = 125, which matches the input.

Assumptions

  • The decay follows a pure exponential law: the rate of decay is proportional to the amount present.
  • The decay constant λ is constant over time (no changes in temperature, pressure, or chemical state that affect λ).
  • The quantity N(t) is continuous and can be measured without error (in practice, measurements have uncertainty).
  • No new quantity is added or removed during the decay process.

When to Use This Calculator

Use this calculator whenever you have two measurements of a decaying quantity at different times and want to find the half-life. This applies to:

  • Radioactive decay – finding the half-life of an isotope from activity counts.
  • Pharmacokinetics – drug elimination half-life from plasma concentrations (though clinical use requires professional judgment).
  • Capacitor discharge – RC circuit time constant related to half-life (t1/2 = RC·ln(2)).
  • Chemical kinetics – first-order reaction half-life, which is independent of initial concentration.
  • Population decay – any process where the decrease rate is proportional to the remaining amount.

The key requirement is that the process is first-order (exponential). If the decay is second-order or zero-order, the half-life depends on the initial concentration and this formula does not apply.

How to Read the Result

The half-life is expressed in the same time unit as the elapsed time you entered. For example, if you entered time in seconds, the half-life is in seconds. The decay constant λ is in reciprocal time units (1/s, 1/min, etc.).

A shorter half-life means faster decay. For instance, carbon-14 has a half-life of about 5,730 years, while radon-222 has a half-life of 3.8 days. The calculator gives you the exact value based on your inputs, not a memorized constant.

Remember that after one half-life, 50% remains; after two, 25%; after three, 12.5%; and so on. The quantity never reaches zero mathematically, but it becomes negligible after about 10 half-lives (less than 0.1% remains).

Common Mistakes and Misconceptions

  • Using the wrong time unit – If you measure time in minutes but the decay constant is per second, your half-life will be off by a factor of 60. Always convert to consistent units.
  • Confusing half-life with mean lifetime – The mean lifetime τ = 1/λ is longer than the half-life: τ = t1/2 / ln(2) ≈ 1.443 × t1/2. For carbon-14, the mean lifetime is about 8,270 years, not 5,730.
  • Thinking half-life depends on initial amount – For exponential decay, it does not. 1000 atoms and 1,000,000 atoms have the same half-life.
  • Applying to non-exponential processes – Bacterial death under a disinfectant may not be exponential if there are resistant subpopulations. The formula only works when the decay rate is proportional to the amount.
  • Rounding too early – If you round ln(2) to 0.693 and the ratio to 2.08, you might get 3.33 s, but for more precise work use more digits.

Limitations of the Formula

The exponential decay model assumes a constant decay probability per unit time. In real systems, this can break down:

  • Radioactive decay is truly exponential only for a single isotope. Mixtures of isotopes with different half-lives produce a composite decay curve that is not a pure exponential.
  • Chemical reactions may deviate from first-order if the reaction is reversible or if the concentration changes significantly.
  • Biological processes often involve multiple compartments (e.g., drug distribution and elimination) that lead to multi-exponential curves, so a single half-life is an approximation.
  • Measurement error – If your two measurements are close together, the calculated half-life can be very sensitive to small errors. For best results, measure over a span of at least one half-life.

Always check whether your data actually fits an exponential trend (e.g., by plotting ln(N) vs. time; a straight line indicates exponential decay).

Frequently Asked Questions

What is the difference between half-life and decay constant?

The decay constant λ is the probability per unit time that a single atom (or quantity unit) will decay. It has units of 1/time. The half-life is the time for half the sample to decay. They are inversely related: t1/2 = ln(2)/λ. A larger decay constant means a shorter half-life.

Can I use this calculator for drug elimination half-life?

Yes, if the drug follows first-order elimination, which most do at therapeutic concentrations. However, this is a mathematical tool for study and planning only, not for clinical dosing. Always consult a healthcare professional for any medical decisions.

How do I find the half-life if I only know the decay constant?

Simply divide ln(2) by the decay constant. For example, if λ = 0.1 s−1, then t1/2 = 0.693147 / 0.1 = 6.93147 seconds. You don’t need initial or final quantities.

What if I have three or more data points?

Use the calculator with any two points, but ideally choose points that are far apart to reduce error. For a more robust estimate, plot ln(N) vs. time and fit a straight line; the slope is −λ. This averages out measurement noise.

Does the half-life change with temperature or pressure?

For radioactive decay, no – it is essentially constant under all normal conditions. For chemical reactions, yes, the rate constant (and thus half-life) typically changes with temperature, following the Arrhenius equation. This calculator assumes a constant λ.

Why is the half-life formula t1/2 = 0.693/λ?

Because ln(2) ≈ 0.693. The derivation comes from solving N(t) = N₀e−λt for t when N(t) = N₀/2. Taking the natural log of both sides gives −λt = ln(1/2) = −ln(2), so t = ln(2)/λ.

Related

Formula used
in n0 | Initial quantity N₀ | - | 1000 | 0
in nt | Quantity after time t N(t) | - | 125 | 0
in t | Elapsed time t | s | 10 | 0
out hl | Half-life t₁/₂ | s | t * ln(2) / ln(n0 / nt) | 4
out k | Decay constant λ | 1/s | ln(2) / hl | 6

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →