Calculator No. 01-7055 · Updated · Formula and assumptions shown below

Half-life 5.0000 h
Decay constant
0.138629 per h
Result, rounded to 6 decimal places
Remaining fraction
0.2500
= Amount remaining ÷ Initial amount
Initial amount
100
Set in the form below
You enter
Initial amount, Amount remaining, Elapsed time (h)
You get
Half-life (h), Decay constant (per h), Remaining fraction
Rounding
4 dp · 6 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

This calculator works out the half-life of a radioactive substance from its initial and remaining amounts and the elapsed time, or the time needed to reach a given remaining fraction. You enter the starting quantity, the quantity left, and the time that has passed; you get back the half-life in the same time unit you used. It is a pure arithmetic tool for the standard exponential decay formula, so it works for any decay process that follows first-order kinetics.

Formula

The half-life (t1/2) is the time required for a quantity to reduce to half its initial value. For first-order decay, the relationship between initial amount N0, remaining amount Nt, and elapsed time t is:

Nt = N0 × (1/2)t / t1/2

Solving for the half-life gives:

t1/2 = t × ln(2) / ln(N0 / Nt)

where:

  • N0 = initial amount (any unit, as long as it matches Nt)
  • Nt = amount remaining after time t (same unit as N0)
  • t = elapsed time (any unit, but the half-life comes out in that same unit)
  • ln = natural logarithm (base e)

The decay constant k is related to the half-life by k = ln(2) / t1/2. Its unit is the reciprocal of the time unit (e.g., per hour, per day).

Worked Example

Suppose you start with 100 g of a radioactive isotope, and after 10 hours you measure 25 g remaining. Using the default values from the calculator:

  1. Compute the ratio N0 / Nt = 100 / 25 = 4.
  2. Take the natural log: ln(4) = 1.386294.
  3. ln(2) = 0.693147.
  4. Half-life = 10 × 0.693147 / 1.386294 = 5.0000 hours.

The calculator shows 5.0000 h for the half-life, 0.138629 per hour for the decay constant, and 0.25 for the remaining fraction.

Assumptions

  • The decay follows first-order kinetics (the rate is proportional to the amount present). This is true for most radioactive isotopes and for many chemical reactions, but not for zero-order or second-order processes.
  • The initial and remaining amounts are measured at the same time points with negligible measurement error.
  • No new material is added or removed during the decay (closed system).
  • The half-life is constant over time; it does not depend on temperature, pressure, or chemical form (for nuclear decay).

How to Read the Result

The half-life tells you how quickly a substance decays. A short half-life (seconds to minutes) means rapid decay; a long one (thousands of years) means the substance remains dangerous or detectable for a very long time. For example, iodine-131 has a half-life of about 8 days, while carbon-14 has a half-life of about 5,730 years. After one half-life, 50% remains; after two, 25%; after three, 12.5%, and so on. The calculator’s “remaining fraction” output shows this directly.

When you use the result, remember that the half-life is a statistical average for a large number of atoms. For a single atom, decay is random—you cannot predict when it will happen, only the probability per unit time.

Common Mistakes and Misconceptions

  • Using the wrong time unit: If you enter time in hours, the half-life comes out in hours. Convert everything to the same unit before calculating.
  • Confusing half-life with decay constant: The decay constant k is the probability per unit time of decay, not the time for half to decay. They are inversely related: k = ln(2) / t1/2.
  • Assuming half-life changes with temperature: For nuclear decay, the half-life is essentially constant under all normal conditions. For chemical reactions, half-life can depend on temperature and concentration, so the first-order assumption must be verified.
  • Rounding too early: If you round ln(4) to 1.39 and ln(2) to 0.69, you get 10 × 0.69 / 1.39 = 4.96, which is 0.8% off. Keep at least 4-5 significant figures in intermediate steps.

When to Use This Calculator

Use this tool whenever you have two measurements of a decaying quantity at different times and need the half-life. Common applications include:

  • Radiometric dating (carbon-14, potassium-argon) – given the ratio of parent to daughter isotopes, you can estimate the age of a sample.
  • Nuclear medicine – knowing the half-life of a tracer helps schedule imaging or treatment.
  • Environmental science – tracking the persistence of pollutants or pesticides that degrade exponentially.
  • Pharmacokinetics – drug elimination half-life (though that is often more complex than simple first-order decay).
  • Chemistry – studying first-order reaction rates, where the half-life is independent of initial concentration.

If you know the half-life and want to find how much remains after a given time, rearrange the formula: Nt = N0 × (1/2)t/t1/2. The same calculator can be used by trial and error, or you can compute the exponent directly.

Limits of the Formula

The formula assumes perfect first-order decay, which is a good model for most radioactive isotopes but not for all processes. For mixtures of two isotopes with different half-lives, the decay curve is a sum of two exponentials, and a single half-life is not meaningful. Also, if the amount remaining is zero or the initial amount is zero, the logarithm is undefined; the calculator will show an error. The formula also fails if you enter a remaining amount larger than the initial amount (which would imply negative decay).

For real measurements, statistical noise and detector background can cause the apparent remaining amount to be slightly off. Always report half-life with an uncertainty if you are doing serious work. For laboratory experiments, follow your lab method, the safety data sheet (SDS) and your supervisor.

Frequently Asked Questions

What is the half-life formula?
The half-life is t1/2 = t × ln(2) / ln(N0 / Nt), where N0 is the initial amount, Nt is the amount after time t, and ln is the natural logarithm. It comes from solving the exponential decay equation for the time when half remains.

How do I find half-life without a calculator?
If you know the fraction remaining, you can count how many half-lives have passed. For example, if 12.5% remains, that is 3 half-lives (100% → 50% → 25% → 12.5%). Divide the elapsed time by the number of half-lives. For fractions that are not simple powers of 1/2, use the logarithmic formula.

Why is half-life constant regardless of amount?
For first-order decay, the rate of decay is proportional to the number of atoms present. So when there are fewer atoms, the rate drops proportionally, and the time to lose half of what is there stays the same. This is why half-life is a fixed property of a radioactive isotope.

Can half-life be negative?
No. Half-life is always a positive time. If you enter a remaining amount greater than the initial amount, the calculator will show “Cannot compute” because the logarithm of a number less than 1 is negative, which would give a negative half-life—physically meaningless.

What is the difference between half-life and decay constant?
The decay constant (k) is the probability per unit time that a single atom will decay. The half-life is the time for half the atoms to decay. They are related by k = ln(2) / t1/2. A large k means a short half-life.

Does half-life depend on temperature or pressure?
For nuclear decay, no. The half-life of a radioactive isotope is essentially independent of temperature, pressure, and chemical environment. For chemical reactions, the half-life can change with temperature and concentration, so you must confirm the reaction is first-order before using this formula.

Related

Formula used
in n0 | Initial amount | - | 100 | 0
in nt | Amount remaining | - | 25 | 0
in t | Elapsed time | h | 10 | 0.000000001
out h | Half-life | h | t * ln(2) / ln(n0 / nt) | 4
out k | Decay constant | per h | ln(2) / h | 6
out frac | Remaining fraction | - | nt / n0 | 4

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →