To convert g force to RPM, you need the radius of the rotor: RPM = 60 / (2π) × √(g × 9.80665 / r), where r is the radius in meters. Enter the g force and the radius (distance from the rotor center to the sample) to get the required revolutions per minute for a centrifuge.
Formula
The relationship between relative centrifugal force (RCF, commonly called g force) and rotational speed is:
RCF = 1.118 × 10-5 × r × RPM2
where RCF is in units of ×g (multiples of Earth’s gravity), r is the rotor radius in centimeters, and RPM is revolutions per minute. To solve for RPM:
RPM = √(RCF / (1.118 × 10-5 × r))
In SI units, the exact formula is RCF = (ω² × r) / g, where ω is angular velocity in radians per second (ω = 2π × RPM / 60), r is radius in meters, and g = 9.80665 m/s². The constant 1.118 × 10-5 combines the conversion from RPM to rad/s, cm to m, and the standard gravity value.
Worked Example
Using the calculator defaults: g force = 1000 ×g, rotor radius = 10 cm.
- Convert radius to meters: 10 cm = 0.1 m.
- Calculate angular velocity: ω = √(g_force × 9.80665 / r) = √(1000 × 9.80665 / 0.1) = √(98066.5) ≈ 313.15 rad/s.
- Convert to RPM: RPM = ω × 60 / (2π) = 313.15 × 60 / 6.2832 ≈ 2990.7 RPM.
The calculator rounds to 2991 RPM. If you then enter 2991 RPM and 10 cm, the reverse calculation gives 1000.3 ×g, confirming the conversion.
Assumptions
- The radius is measured from the centrifuge axis to the sample midpoint (not the tube bottom).
- Standard gravity is 9.80665 m/s².
- The rotor spins at a constant speed; acceleration/deceleration phases are ignored.
Why the Radius Matters
Two samples in the same rotor experience different g forces if they are at different distances from the axis. A tube placed at 7 cm from the center gets less force than one at 10 cm at the same RPM. This is why centrifuge manuals often list both RPM and RCF for each rotor: the RCF is only valid at a specified radius. When you use a fixed-angle rotor, the effective radius changes as the tube angle changes. Most protocols specify the g force (RCF) rather than RPM precisely because RCF is independent of rotor geometry. If you know the g force and the rotor’s maximum radius, you can calculate the RPM for any rotor.
How to Measure or Find the Radius
The radius is the distance from the center of the rotor to the point in the tube where the sample sits. For a swinging-bucket rotor, this is the bottom of the bucket when horizontal. For a fixed-angle rotor, the radius is usually given as the average or maximum radius in the rotor’s manual. If you don’t have the manual, measure with a ruler from the center of the rotor shaft to the middle of the tube opening when the rotor is at rest. For angle rotors, the sample’s midpoint is roughly at the tube’s center, not the bottom. Many protocols state the g force and assume a standard radius (e.g., 10 cm), but for accurate work, use the exact radius for your rotor.
Common Mistakes and Pitfalls
- Using tube length instead of radius: The radius is not the tube length; it’s the distance from the rotor center to the sample.
- Mixing units: The constant 1.118 × 10-5 works only with radius in cm. If you use meters, the constant becomes 1.118 × 10-3.
- Confusing RPM and RCF: RPM is revolutions per minute (a speed), RCF is relative centrifugal force (a multiple of g). They are not interchangeable.
- Ignoring rotor type: The same RPM on different rotors gives different g forces because radii differ.
Practical Examples
Typical laboratory applications:
- Cell pelleting: often 300–500 ×g for 5–10 minutes. With a 10 cm radius, that’s about 1640–2110 RPM.
- Bacterial harvesting: 5000–10000 ×g. At 10 cm radius, that’s 6690–9460 RPM.
- Microcentrifuge: 12000–20000 ×g. At a 6 cm radius, that’s 13400–17300 RPM.
- Ultracentrifugation: 100000 ×g or more. At 8 cm radius, that’s about 33400 RPM.
These numbers show that a small change in radius significantly changes the required RPM. Always verify with the exact rotor dimensions.
Limitations of the Formula
The formula assumes a point sample at a fixed radius. In reality, the sample has volume, so different parts of the tube experience different g forces. For most protocols, the difference is negligible, but for precise sedimentation studies, the radius at the meniscus and at the bottom matter. Also, the formula does not account for rotor acceleration or deceleration time, which can affect total sedimentation. The g force is a measure of acceleration, not force in newtons; to get force on a particle, you’d multiply by the particle’s mass, but that’s rarely needed in centrifuge work.
Frequently Asked Questions
What is the difference between g force and RPM?
G force (RCF) is the relative centrifugal acceleration compared to Earth’s gravity, while RPM is the rotational speed. G force depends on both RPM and the radius; the same RPM gives different g forces on different rotors.
How do I convert g force to RPM without knowing the radius?
You can’t. The radius is essential. If you don’t know it, check the centrifuge rotor manual or measure the distance from the center to the sample tube. Many protocols assume a radius (often 10 cm), but that’s an approximation.
Why do some protocols say “RPM” and others say “g force”?
Protocols that say g force are more reproducible across different centrifuges, because g force is independent of rotor geometry. RPM is only meaningful for a specific rotor. Always use g force when possible, and convert to RPM for your machine.
Does the angle of a fixed-angle rotor affect the calculation?
Yes. In a fixed-angle rotor, the sample is not at the bottom of the tube when spinning; it sits at an angle. The effective radius is shorter than the maximum radius. Use the average radius specified by the rotor manufacturer, not the tube length.
Can I use this calculator for any centrifuge?
Yes, as long as you enter the correct radius for your rotor and sample position. The formula is universal for any centrifuge that spins a sample at a fixed radius.
What if my centrifuge only shows RPM and I need g force?
Use the reverse calculation: RCF = 1.118 × 10-5 × r × RPM². Enter your RPM and radius in the second output of the calculator to get the g force.
Always follow your lab’s standard operating procedures, the centrifuge manufacturer’s guidelines, and the safety data sheet for the materials you are handling. Check the rotor’s maximum speed rating and never exceed it.
Related
Formula used
in g | G force (RCF) | ×g | 1000 | 0 in r | Rotor radius | cm | 10 | 0.1 out rpm | Rotational speed | RPM | 60 / (2 * pi) * sqrt(g * 9.80665 / (r / 100)) | 0 out rcf | G force (RCF) | ×g | (2 * pi * rpm / 60)^2 * (r / 100) / 9.80665 | 1
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Relative Molecular Mass of Copper Sulfate0.0732 mol/L
- Bag Volume Calculator: How to Measure Any Bag25.50 L
- Molar Mass of Copper(II) Sulfate (CuSO₄)0.0468 mol/L
- Molar Mass of Hydrated Copper Sulphate (CuSO4·5H2O)0.0468 mol/L
- Molar Mass of Copper(II) Sulfate: Exact Value & How to Find It0.0732 mol/L
- Molar Mass of CuSO4: How to Calculate It0.1000 mol