A serial dilution is a stepwise reduction of a stock concentration by a constant factor, usually 10-fold, 2-fold, or 5-fold, achieved by repeatedly mixing a small volume with a larger volume of diluent. You start with a concentrated stock, transfer a set volume into fresh diluent, mix, then repeat that transfer from the previous tube into the next. Each successive tube contains a predictable fraction of the original concentration, which lets you create a range of standards or countable plates without making many separate weighings.
Note: The calculator above shows the concentration after each of up to 4 steps using your chosen transfer and diluent volumes. The dilution factor per step is (v + dv)/v, so a 1 mL transfer into 9 mL diluent gives a 10-fold dilution each step.
Formula
The core relation for a single dilution step is:
Cfinal = Cstock × (Vtransfer / (Vtransfer + Vdiluent))
- Cstock = concentration of the solution you are diluting (e.g., mg/mL, mol/L, or CFU/mL)
- Vtransfer = volume you pipette from the previous tube (mL)
- Vdiluent = volume of diluent already in the new tube (mL)
- Cfinal = concentration in the new tube after mixing
After n identical steps, the concentration is:
Cn = C0 × (Vtransfer / (Vtransfer + Vdiluent))n
If you want a specific dilution factor D (e.g., 10, 100, 1000), you can solve for the volumes: choose Vdiluent = 9 mL and Vtransfer = 1 mL for a 10-fold step; for a 2-fold step, use 1 mL transfer into 1 mL diluent.
Worked Example
Suppose you have a 100 mg/mL stock solution and you want to make 4 serial 10-fold dilutions. Use 1 mL of stock into 9 mL of diluent for the first tube, then 1 mL from that tube into 9 mL fresh diluent for the second, and so on.
- Step 1: C1 = 100 × (1 / (1 + 9)) = 100 × 0.1 = 10.00 mg/mL
- Step 2: C2 = 100 × (0.1)2 = 100 × 0.01 = 1.00 mg/mL
- Step 3: C3 = 100 × (0.1)3 = 100 × 0.001 = 0.10 mg/mL
- Step 4: C4 = 100 × (0.1)4 = 100 × 0.0001 = 0.01 mg/mL
Using the calculator with stock volume 1 mL, diluent volume 9 mL, 4 steps, and starting concentration 100 mg/mL gives exactly these results: 10, 1, 0.1, and 0.01 mg/mL. Notice that the total volume in each tube is 10 mL, and you discard 1 mL after the last step if you only need 9 mL of the final dilution.
Assumptions
- You mix thoroughly after each transfer so the solution is homogeneous.
- The volumes are additive (true for most aqueous solutions at moderate concentrations).
- The pipette transfers exactly the nominal volume.
- The diluent does not react with the solute or alter its activity.
- Each step is performed with a fresh pipette tip to avoid carryover.
How to Perform a Serial Dilution Step by Step
- Label tubes 1, 2, 3, …, n. Add the chosen volume of diluent to each tube (e.g., 9 mL for a 10-fold series).
- Mix the stock solution thoroughly. Pipette the transfer volume (e.g., 1 mL) into tube 1.
- Vortex or pipette-mix tube 1 at least 5–10 times. Change the tip.
- Transfer the same volume from tube 1 to tube 2. Mix well. Change the tip.
- Repeat for each subsequent tube. After the last tube, discard the tip and any excess volume if you only need the final volume.
- Use the dilutions immediately or store according to your protocol. For microbiological work, plate a known volume from each dilution onto agar to count colonies.
Always change the pipette tip between transfers. If you use the same tip, you carry over concentrated solution and contaminate the next tube, ruining the series.
Choosing the Right Dilution Factor
The dilution factor you choose depends on the assay or experiment. For counting bacteria or yeast, a 10-fold series is standard because it spans a wide range (101 to 108 or more) with few tubes. For enzyme assays or protein standard curves, a 2-fold series gives more points in a narrow range, which is useful for accurate interpolation. A 5-fold series is a compromise when you need a moderate range with fewer tubes.
Consider the expected concentration of your sample. If you expect 106 CFU/mL, you might plate the 104, 105, and 106 dilutions to get countable plates (30–300 colonies). For a protein assay with a standard curve from 0 to 2 mg/mL, a 2-fold series from 2 mg/mL down to 0.0625 mg/mL gives 6 points plus a blank.
Common Problems and How to Avoid Them
- Not mixing enough: Incomplete mixing leaves concentration gradients. Vortex each tube for at least 5 seconds, or pipette up and down 10 times.
- Using the same tip: This is the most frequent error. Always use a fresh tip for each transfer.
- Incorrect volume readings: Pipettes need calibration. Check the calibration regularly, and use the correct pipette range (e.g., don’t pipette 10 µL with a 1000 µL pipette).
- Adding diluent to the stock: Always add the concentrated solution to the diluent, not the reverse, unless your protocol says otherwise. This avoids local high concentrations and keeps volumes accurate.
- Forgetting to discard the final transfer: If you transfer 1 mL from tube 3 to tube 4, you now have 10 mL in tube 4. If you only need 9 mL, discard 1 mL after mixing, or use a larger final tube.
- Rounding too early: Keep at least 3 significant figures in your calculations. Round only the final reported value.
Serial vs. Parallel Dilution
A serial dilution uses the previous tube as the source for the next, so the concentrations form a geometric series (e.g., 1, 0.1, 0.01, 0.001). A parallel dilution, also called a simple dilution, makes each dilution directly from the stock (e.g., 1 mL stock + 9 mL diluent for 0.1, 2 mL stock + 8 mL diluent for 0.2, etc.). Parallel dilutions are more accurate if you need non-geometric concentrations, but they require more stock and more pipetting. Serial dilutions save stock and time when you need a wide range of concentrations, but errors accumulate with each step—a 5% error in the first transfer becomes a 5% error in all subsequent tubes.
Applications and Real-World Examples
- Microbiology: To count viable cells, you plate 0.1 mL from dilutions 10-4 to 10-7 onto agar. After incubation, count colonies and multiply by the dilution factor and the volume factor to get CFU/mL.
- Biochemistry: Preparing a standard curve for a Bradford or BCA protein assay. You might make 2-fold serial dilutions of a 1 mg/mL BSA stock to get 0.5, 0.25, 0.125, etc.
- Molecular biology: Making serial dilutions of a DNA ladder or a primer stock for PCR optimization.
- Clinical chemistry: Diluting a serum sample to bring an analyte concentration within the linear range of an assay.
- Environmental testing: Diluting a water sample to count coliform bacteria using the most probable number (MPN) method.
In every case, the key is to track your dilution factor and total dilution. The total dilution after n steps is the product of each individual dilution factor. For a 10-fold series, the total dilution is 10n.
Frequently Asked Questions
What is the difference between dilution factor and dilution ratio?
Dilution factor is the total volume divided by the aliquot volume. For 1 mL sample + 9 mL diluent, the dilution factor is 10 (or 10-fold). Dilution ratio is usually written as sample:diluent, so 1:9 means 1 part sample and 9 parts diluent, which equals a 10-fold dilution. Be careful: some fields write 1:10 to mean the same 10-fold dilution, so check your lab’s convention.
How do I calculate the concentration after a serial dilution?
Multiply the starting concentration by the dilution factor raised to the power of the number of steps. For a 10-fold series starting at 100 mg/mL, after 3 steps the concentration is 100 × (0.1)3 = 0.1 mg/mL. If you use a different factor, replace 0.1 with 1/factor.
Why do I need to change pipette tips between each dilution?
If you reuse the tip, the outside and inside carry a small amount of the previous solution. That carryover contaminates the next tube, making the dilution inaccurate. Even a tiny droplet (0.5 µL) can shift a 1:10 dilution significantly. Fresh tips ensure each transfer is only the intended volume.
Can I do a serial dilution in a 96-well plate?
Yes. You add diluent to each well (e.g., 100 µL), then add the sample to the first well (e.g., 100 µL), mix, and transfer 100 µL to the next well, discarding the final 100 µL after the last well. This is common for ELISA and cell viability assays. The volumes are smaller, so accuracy depends on precise pipetting.
What is the best way to mix a small volume in a tube?
For volumes under 1 mL, pipette up and down at least 10 times. For larger volumes, vortex for 5–10 seconds. Avoid creating bubbles, which can denature proteins or cause inaccurate pipetting. If you use a vortex, hold the tube at an angle to prevent liquid from hitting the cap.
How do I know which dilution to plate for counting colonies?
You want a plate with 30–300 colonies to be statistically reliable. If you expect 106 CFU/mL, plating 0.1 mL of the 10-5 dilution gives 106 × 10-5 × 0.1 = 1 colony, which is too few. The 10-3 dilution gives 106 × 10-3 × 0.1 = 100 colonies, which is ideal. Plate a few dilutions to ensure you hit the countable range.
Always follow your lab protocol and the safety data sheet (SDS) for the reagents you handle. For microbiological work, use aseptic technique to avoid contamination.
Related
Formula used
in v | Stock volume per transfer | mL | 1 | 0.000001 in v | Diluent volume per tube | mL | 9 | 0.000001 in n | Number of dilution steps | - | 4 | 1 in c0 | Starting concentration | mg/mL | 100 | 0 out c1 | Concentration after step 1 | mg/mL | c0 * (v / (v + dv)) | 4 out c2 | Concentration after step 2 | mg/mL | c0 * (v / (v + dv))^2 | 4 out c3 | Concentration after step 3 | mg/mL | c0 * (v / (v + dv))^3 | 4 out c4 | Concentration after step 4 | mg/mL | c0 * (v / (v + dv))^4 | 4
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Relative Molecular Mass of Copper Sulfate0.0732 mol/L
- Bag Volume Calculator: How to Measure Any Bag25.50 L
- Molar Mass of Copper(II) Sulfate (CuSO₄)0.0468 mol/L
- Molar Mass of Hydrated Copper Sulphate (CuSO4·5H2O)0.0468 mol/L
- Molar Mass of Copper(II) Sulfate: Exact Value & How to Find It0.0732 mol/L
- Molar Mass of CuSO4: How to Calculate It0.1000 mol