This calculator determines the ideal gas constant k (more commonly written as R) for a given set of units, or converts a known value from one unit system to another. You enter the numerical value and its current units, and the calculator returns the equivalent value in joules per mole-kelvin (J·mol⁻¹·K⁻¹), the SI standard. It also shows the value in liter-atmospheres per mole-kelvin (L·atm·mol⁻¹·K⁻¹) for convenience.
Formula
The ideal gas constant R (often denoted k in some textbooks, especially in physics when referring to the Boltzmann constant per molecule) relates the macroscopic properties of an ideal gas: pressure (P), volume (V), amount of substance (n), and temperature (T) in the equation:
PV = nRT
Where:
- P = absolute pressure (Pa, atm, bar, etc.)
- V = volume (m³, L, etc.)
- n = amount of substance (mol)
- T = absolute temperature (K)
- R = ideal gas constant (units depend on the units of P, V, n, T)
The numerical value of R depends entirely on the units you choose for pressure and volume. The SI value is:
R = 8.31446261815324 J·mol⁻¹·K⁻¹
This is an exact defined constant, derived from the Boltzmann constant kB = 1.380649 × 10⁻²³ J/K and Avogadro’s number NA = 6.02214076 × 10²³ mol⁻¹, so that R = kB × NA.
Worked Example
Suppose you have a value of R = 8.314 J·mol⁻¹·K⁻¹ (the default in the calculator). To convert this to L·atm·mol⁻¹·K⁻¹, you use the conversion factor 1 L·atm = 101.325 J.
Step 1: Start with the value in J·mol⁻¹·K⁻¹: 8.314 J·mol⁻¹·K⁻¹
Step 2: Divide by 101.325 J per L·atm: 8.314 / 101.325 = 0.08206 L·atm·mol⁻¹·K⁻¹
So 8.314 J·mol⁻¹·K⁻¹ equals 0.08206 L·atm·mol⁻¹·K⁻¹. The calculator shows this as 0.0821 when rounded to 4 decimal places.
Assumptions
- The gas behaves ideally (no intermolecular forces, negligible molecular volume).
- Temperature is in kelvin (K), not Celsius or Fahrenheit.
- The conversion factors are exact: 1 L·atm = 101.325 J, 1 L·bar = 100 J, 1 cal = 4.184 J.
- The value of R is the same for all ideal gases regardless of chemical identity.
Why Is It Called the “k Constant”?
In many introductory physics and chemistry texts, the symbol k is used for the Boltzmann constant (kB = 1.380649 × 10⁻²³ J/K), which relates the average kinetic energy of particles to temperature. However, in chemistry and engineering, the universal gas constant is almost always written as R. Some older or more physics-oriented textbooks use k to denote the gas constant per molecule, while R is per mole. The relationship is R = kB × NA. So if you see “k constant” in a chemistry context, it usually means the ideal gas constant R, and in a physics context it may mean the Boltzmann constant. The calculator above treats “k” as the gas constant per mole, which is the most common usage in stoichiometry and gas law problems.
Common Values and Unit Conversions
The ideal gas constant appears in many forms. Here are the most frequently used values:
- 8.314 J·mol⁻¹·K⁻¹ (SI)
- 0.08206 L·atm·mol⁻¹·K⁻¹ (common in chemistry when pressure is in atm and volume in liters)
- 8.314 × 10⁻³ kJ·mol⁻¹·K⁻¹ (when using kilojoules)
- 1.987 cal·mol⁻¹·K⁻¹ (when using calories)
- 0.08314 L·bar·mol⁻¹·K⁻¹ (when pressure is in bar)
- 62.36 L·torr·mol⁻¹·K⁻¹ (when pressure is in torr)
The calculator converts any of these to the SI value. For example, if you enter 0.08206 with units L·atm/(mol·K), the calculator multiplies by 101.325 to get 8.314 J·mol⁻¹·K⁻¹.
How to Choose the Right Value
When solving a gas law problem, you must pick the value of R that matches the units of pressure and volume you are using. The rule is simple: the units of R must cancel with the units of P and V to leave you with mol and K.
- If pressure is in pascals (Pa) and volume in cubic meters (m³), use R = 8.314 J·mol⁻¹·K⁻¹ (since 1 J = 1 Pa·m³).
- If pressure is in atmospheres (atm) and volume in liters (L), use R = 0.08206 L·atm·mol⁻¹·K⁻¹.
- If pressure is in bar and volume in liters, use R = 0.08314 L·bar·mol⁻¹·K⁻¹.
- If you are working in calories, use R = 1.987 cal·mol⁻¹·K⁻¹.
For example, to find the volume of 1.00 mol of gas at 300 K and 1.00 atm, you would use PV = nRT → V = (1.00 mol × 0.08206 L·atm·mol⁻¹·K⁻¹ × 300 K) / 1.00 atm = 24.6 L. If you mistakenly used 8.314, you would get 2494 L, which is wrong by a factor of 101.325.
Common Mistakes and Misconceptions
One frequent error is using Celsius instead of kelvin. Always convert °C to K by adding 273.15. Another is mixing units—for example, using pressure in atm but volume in m³, or using the SI value of R with volume in liters. Always check that the units in your equation cancel.
A common misconception is that R changes for different gases. It does not—it is a universal constant for all ideal gases. Real gases deviate at high pressure and low temperature, but the constant itself remains the same; the ideal gas law just becomes less accurate.
Another misconception is that the “k constant” is always the Boltzmann constant. In chemistry problem sets, “k” often refers to the rate constant in kinetics, but that is a completely different quantity with units that vary by reaction order. The calculator on this page specifically addresses the ideal gas constant, which is the most common “k” in gas law contexts.
Frequently Asked Questions
What is the difference between R and k? In thermodynamics, R is the universal gas constant per mole (8.314 J·mol⁻¹·K⁻¹), while k (or kB) is the Boltzmann constant per molecule (1.380649 × 10⁻²³ J/K). They are related by Avogadro’s number: R = kB × NA. In some physics texts, k is used for the gas constant per molecule, but in chemistry, R is standard.
Why is the ideal gas constant different in different units? Because pressure and volume have many possible units, the numerical value of R must change to keep the equation dimensionally consistent. For example, 1 L·atm is a different amount of energy than 1 J, so the number in front of R changes accordingly.
Is the ideal gas constant exact? Yes, the SI value of R is exact by definition since 2019, when the Boltzmann constant was fixed. The value 8.31446261815324 J·mol⁻¹·K⁻¹ is exact, but most calculations use 8.314 for simplicity.
Can I use R for real gases? The ideal gas constant works for real gases only under conditions where the gas behaves ideally—low pressure and high temperature. For real gases, you would use the van der Waals equation or other equations of state, but the constant R still appears in those equations.
How do I remember which value of R to use? Look at the units of pressure and volume in your problem. If pressure is in atm and volume in L, use 0.08206. If pressure is in Pa and volume in m³, use 8.314. If you are unsure, convert everything to SI units (Pa, m³, mol, K) and use 8.314.
What is the value of k in the ideal gas law? In the ideal gas law PV = nRT, the constant is R, not k. However, some textbooks write it as PV = NkT, where N is the number of molecules and k is the Boltzmann constant. In that form, k = 1.380649 × 10⁻²³ J/K. The calculator on this page uses the molar form, so it treats “k” as R.
Related
Formula used
in k | Value of k (R) | - | 8.314 | 0.001 sel u | Current units | J/(mol·K)=1, L·atm/(mol·K)=101.325, L·bar/(mol·K)=83.1446, cal/(mol·K)=4.184, m³·Pa/(mol·K)=1 out kj | k in J/(mol·K) | J·mol⁻¹·K⁻¹ | k * u | 4 out ka | k in L·atm/(mol·K) | L·atm·mol⁻¹·K⁻¹ | kj / 101.325 | 4
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Relative Molecular Mass of Copper Sulfate0.0732 mol/L
- Bag Volume Calculator: How to Measure Any Bag25.50 L
- Molar Mass of Copper(II) Sulfate (CuSO₄)0.0468 mol/L
- Molar Mass of Hydrated Copper Sulphate (CuSO4·5H2O)0.0468 mol/L
- Molar Mass of Copper(II) Sulfate: Exact Value & How to Find It0.0732 mol/L
- Molar Mass of CuSO4: How to Calculate It0.1000 mol